green/red indicator
yellow indicator
buttonLED display
USB charge
After power on, the detector self examines, then enters
the preheating state, the preheating state continues 180s,
at this time the detector has no monitoring function.
After the preheating is over, the detector enters the
normal monitoring state. Under this condition, the detector
will inspect itself by pressing the key.
When the indoor gas or LPG gas concentration exceeds
the alarm value, the detector enters the alarm state, and
the normal monitoring state is restored when the indoor
gas or LPG concentration is lower than the alarm value.
When the sensor failure, the detector will enter the
failure state, re power off, again on power, if still a state of
failure, please call after-sales service phone for
maintenance.
3.Function Introduction
Installation method
Installation method A (adhesive back glue)
1) Used for ceramic tile, glass, wood new building materials,
stainless steel and other wall.
2) Before installation, please keep the wall clean.
3) Please install and fix the location before installing.
4) Please stick to the equipment and keep it for more than 10
seconds to maintain.Paste stability.
Installation method B (hanging nail)
1) Suitable for cement surface, putty wall, etc.
2) Fix the equipment on the nail according to the
position of hanging hole.
PS1: Attach the wall plate to a groove in the back of the main engine.
PS2: The installation is completed by rotating the wall plate in accordance with the indicated
direction of the groove.
PS3: 5V MicroUSB interface charging line is used for power supply.
PS1
PS2
PS2
The independent combustible gas detector FTH-KBF1,
measuring 0~100%LEL, is an intelligent monitoring device
for natural gas and liquefied petroleum gas. The alarm and
red warning signals will be issued once the concentration
of the monitored gas reaches a dangerous level due to
leakage and other reasons. Ensure that gas leakage
information is transmitted promptly and without dead ends,
while closing the solenoid valve, cutting off the leakage
source and protecting the user's family safety.
1. Product Introduction
Self check status: Green, red and yellow indicator
lights turn out in turn, then LCD screen gradually displays
"8.88", and finally buzzer rings.
Preheating state: Green indicator lights flicker once
per second.
Normal monitoring status: The green indicator
gradually darkens, then gradually brightens and circulate
repeatedly.
Alarm status: Red indicator is fast flashing, buzzer
ringing quickly, LCD display methane concentration value
(unit:%LEL).
Fault status: Yellow indicator lights flicker, buzzer once
a second, LCD screen shows "Err".
2. Indicator State Description
4.Installation Instructions
Installation Location
≤0.3m
≤5m
1.Equipment and gas cookers
should be located in the same
indoor space;
2.Equipment distance from
flammable gas leakage is best
maintained at 1 to 3 meters;
3.It should be fixed at a fixed
position at a height of 30
centimeters from the ceiling.

7.Technology Specification6. Problems and Solutions
Problem Cause Analysis Solution
Green power
indicator does
not work
Press
“self-test/mute”
button but
no response
No response
to target gas
Keep alarming
after warm-up
Connectivity of
power supply
Power indicator breaks
Circuit breaks
Warm-up
does not finish
Circuit breaks
Work environment
filled with organics
like smoke,
alcohol steam,
fume, perfume
and so on
The storage period
is too long
Circuit breaks
Check the
connectivity
Call customer service
Call customer service
Wait till
warm-up finishes
Call customer service
Move the device
to clean air the test
if it work normally
Supply power to age
for over 2 hours
Call customer service
Model
Detecting Gas
Working Environment
Sampling Method
Testing Range
Alarm Presetting Level
Warm-up Time
Sensor Type
Life Span
Working Voltage
Weight
Dimension
Alarm Method
Alarm Sound
5 Yeas(Under normal working environment)
5±0.1V
71g
86mmXH29mm
Visual, audible signals alarm
≥70dB
Temperature: 0 ~ 40 degree Celsius
Humidity: <95%RH (No Frost)
FTH-KBF1
Natural gas ( CH4, Methane)
Natural diffusion
0~100% LEL
7% LEL
180
Semiconductor
8. After-sales policy and warranty policy
THIS PRODUCT SUPPORTS ONE-YEAR FREE REPLACEMENT, BUT IF NON-
NORMAL USE DOES NOT ENJOY THE WARRANTY (FOR EXAMPLE:
LIGHTNING, VOLTAGE INSTABILITY, WATER AND OTHER MAN-MADE) .
Matters needing attention
1)It is not suitable to be installed too close to the stove.
2)It is not suitable to be installed in the place where the
smoke is too large.
3)It is not suitable to be installed in the exhaust fan,
doors and windows, bathroom and other water vapor, gas.
Where the flow is larger.
1. Please start a self check button every 6 months to
ensure the working condition of the equipmentisnormal .
2. Please use soft brush and dry flannel to clean the
surface dust and oil to ensure good air permeability and
good indication. Do not use cleaning agent, bleach powder
or polish when cleaning.
3. This product is designed for indoor use only. Please
avoid equipment contact with rain or wet gas. At the same
time, avoid falling equipment, do not knock, open or
change equipment, otherwise it may cause product failure.
4. Under normal use, the maximum useful life of the
equipment is 5 years. New equipment should be replaced
over the period of use.
5.Equipment Maintenance