FS M6800 Series Manuel utilisateur

ALM
SYS
14710 13 16 19 22
2 3
CONSOLE RESET LEDTEST
56
8911 12 14 15 17 18 20 21 23 24
MGMT1 MGMT2
1
4
7
10
13
16
19
22
TSP16
V2.0
PLATE-FORME OTN DE SÉRIE M6800
OTN PLATFORM DER M6800-SERIE
M6800 SERIES OTN PLATFORM
Quick Start Guide
Quick-Start Anleitung
Guide de Démarrage Rapide

1
EN
Introduction
M6800-TSP16 is an OTN transmission platform customized for Data Center Interconnect (DCI)
applications. It's up to eight single wavelength 200G channels, with 8x 200G CFP2 coherent optics
uplinks on the line side, and 16x 100G QSFP28 on the client side.
ALM
SYS
2
1 4 7 10 13 16 19 22
3 5 6 8 9 11 12 14 15 17 18 20 21 23 24 CONSOLE RESET LED TEST
MGMT1 MGMT2
TSP16
1
4
7
10
13
16
19
22
M6800-TSP16
Accessories
Power Cord x2 Console Cable x1 Ethernet Cable x1
Grounding Cable x1Cable Manager x1 Mounting Bracket x2 ESD Wrist Strap x1
M4 Screw x8M6 Screw Set x4
CD x1

2
EN
Hardware Overview
ALM
SYS
2
1 4 7 10 13 16 19 22
3 5 6 8 9 11 12 14 15 17 18 20 21 23 24 CONSOLE RESET LED TEST
MGMT1 MGMT2
TSP16
1
4
7
10
13
16
19
22
Front Panel Ports
Front Panel LED
Port Description
Line Port
MGMT1~2
CONSOLE
Clinet Port
Support 8x coherent 200G CFP2
Connect to the local network management computer
Debugging & Upgrading port
Support 16x 100G QSFP28
CFP2
RJ45 ETH
Micro USB
QSFP28
Port Type
Line Port MGMT1
CONSOLEClinet Port
MGMT2
ALM
SYS
2
1 4 7 10 13 16 19 22
3 5 6 8 9 11 12 14 15 17 18 20 21 23 24 CONSOLE RESET LED TEST
MGMT1 MGMT2
TSP16
1
4
7
10
13
16
19
22
ALM
SYS
LED Status Description
ALM
SYS
Slow Flash of Red Light There is a major alarm of the device.
Quick Flash of Red Light
Always OFF
Slow Flash of Green Light
Always OFF
Always Red
There is a critica alarm of the device.
There is no alarm of the device.
There is a minor alarm of the device.
The system is not normally enabled.
The system works normally.

3
EN
Site Environment
measures must be taken.
Ensure there is no water on the storage oor and no leakage to the packing box of the equipment.
Avoid automatic re ghting facilities, heating system and other places where leakage may occur.
Keep the equipments indoors. If it is in rainy season or in humid environment, dehumidication
LED Status Description
Port Indicator Quick Flash of Red Light There is a mismatch alarm of the port.
Always OFF
Always Green
Always Red
The port is disabled.
There is no los and mismatch alarm of the port.
There is a los alarm of the port.
LED Status Description
FAN Always Red There is alarm of those fans.
Always Green There is no alarm of those fans.
Back Panels
Back Panel LED
FAN FAN FAN
3 Fans
Dual AC Power, 100~240V
FAN
FAN FAN FAN

4
EN
ALM
SYS
14710 13 16 19 22
23
CONSOLE RESET LEDTEST
56
8911 12 14 1517 18 20 2123 24
MGMT1 MGMT2
1
4
7
10
13
16
19
22
TSP16
Installing
13 16 19 22
CONSOLE RESET LED TEST
14 15 17 18 20 21 23 24
MGMT1 MGMT2
7
10
13
16
19
22
Installing Mounting Brackets
1. Secure the mounting brackets to the two sides of the 200G transponder with 8x M4 screws.
1. Put the 200G transponder on the shelf in the cabinet.
2. Install and tighten the panel with 4 sets of M6 screws.
3. Cable manager can be installed together with mounting brackets to the cabinet.
ALM
SYS
TSP16

5
EN
ALM
SYS
14710 13
2 3
56
8911 12 14 15
1
4
7
10
TSP16
1. Before touching any device or module, wear an ESD wrist strap or ESD gloves to protect sensitive
components against electrostatic discharge from the human body.
2. Connect other end of the ESD wrist strap to the PGND point on the device.
1. Secure the grounding lug to the grounding point on the chassis front panel with the washers and
screws.
2. Connect the other end of the cable to a proper earth ground, such as the rack in which 200G
transponder is mounted.
Wearing ESD Wrist Strap
4710 13 16 19 22
CONSOLE RESET LED TEST
56
8911 12 14 15 17 18 20 21 23 24
MGMT1 MGMT2
1
4
7
10
13
16
19
22
Grounding the 200G Transponder
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.

6
EN
19 22
CONSOLE RESET LED TEST
20 21 23 24
MGMT1 MGMT2
13
16
19
22
Connecting Power Cord
1. Plug AC power cord into the power port on the front panel of AC power module.
2. Connect the other end of the power cord to an AC power source.
ALM
SYS
14710 13 16 19 22
2 3
CONSOLE RESET LED TEST
56
8911 12 14 15 17 18 20 21 23 24
MGMT1 MGMT2
1
4
7
10
13
16
19
22
TSP16
Connecting QSFP28 Transceiver
1. Plug the QSFP28 transceiver into the QSFP28 slot on transponder.
2. Connect one end of ber cable to the QSFP28 transceiver.
3. Connect the other end of ber cable to switch.
WARNING: Do not install power cables while the power is on.

7
EN
1. Connect one end of the standard RJ45 Ethernet cable to the MGMT1&2 port on the 200G
transponder.
2. Connect the other end of cable to a computer.
ALM
SYS
14710 13 16 19 22
2 3
CONSOLE RESET LED TEST
56
8911 12 14 15 17 18 20 21 23 24
MGMT1 MGMT2
1
4
7
10
13
16
19
22
TSP16
Connecting Coherent CFP2 Transceiver
1. Plug the CFP2 transceiver into the CFP2 slot on transponder.
2. Connect one end of ber cable to the CFP2 transceiver.
3. Connect the other end of ber cable to mux demux or optical amplier module.
Connecting to the Management Ports
19 22
CONSOLE RESET LED TEST
20 21 23 24
MGMT1 MGMT2
19
22

8
EN
Conguring the M Series Platform
Conguring the M Series Platform Using the Web-based Interface
Step 1: Connect your computer with the network cable to any Ethernet MGMT port of the NMU
Step 2: Get the NMS software from the CD of chassis accessories or deownload the le “NMS software”
module.
online, and then install it.
License Tool
Please Enter the Key:
Key:
Validate Close
NMS Server
Step 3: Double Click“NMS Server” icon on the desktop and the dialogue box of license validation will
pop up.Enter the license key(included in the CD) to nish validation. (If you can’t nd the
license key,please contact FS asles manager for help.)

9
EN
Step 4: Then the NMS server interface pops up. Double click“Start NMS Server" to run the server,
when it prompts“Please connect your client to the web server on port: 9090”, it means that
you have successfully started the NMS server. And then you can close the NMS Server window,
the server is still running in the background.
Step 5: Open a browser window. (Recommend IE11.0 and above version or Google Chrome browser).
(1) If you log in from local NMS host, enter localhost:9090 in the address bar to open the login
interface.
(2) If you log in from other remote host, enter the server IP address XXX.XXX.XXX.XXX:9090
(IP address of NMS server) to open the login interface.
NMS
Options Edit Help
Start NMS Server
Start the NMS Server
Start NMS Server Shutdown NMS Server Reiniyialize NMS
Start NMS Server
NMS modules started successfully at Oct 08,2018 02:44:50 PM
Please connect your client to the web server on port 9090
Process : NmsSAServerFE Started
Process : EventFE Started
Process : MapFE Started
Process : PolicyFE Started
Process : AlertFE Started
Started
Started
Process : NmsMainFE Started
Process : WebNMSMgmtFEProcess Started
Table des matières
Langues :
Manuels Système de microphone populaires d'autres marques

Sennheiser
Sennheiser Evolution Wireless Digital EW-DX EM 2 Manuel utilisateur

Alpha Technologies
Alpha Technologies RBMS Manuel utilisateur

SWIT Electronics Co.,LTD.
SWIT Electronics Co.,LTD. CW-S150 Manuel utilisateur

Shure
Shure UA844 Manuel utilisateur

Panasonic
Panasonic SHFX70 - DVD HOME THEATER WIRELESS SYSTEM Manuel utilisateur

Pyle
Pyle PDWM5000 Manuel utilisateur