Frigor Tstat Series Manuel utilisateur

Tstat Series
- 1 -
Descriptions
Tstat6
This full-featured CPU based thermostat is designed for small cooling and heating air handling sys-
tems in residential and commercial facilities. The unit provides features which eclipse standard me-
chanical thermostats at a price that fits conventional HVAC projects.
Highlights:
-Tight control of 0.5°C provides comfortable indoor environment.
-High impact plastic enclosure provides durability in commercial environments.
-Customizable sequence of operation table (FCU with modulating or on/off valve,single or 3-speed fan,
pressure independent VAV, stage sequencer)
-Available in Clock, Clock & Humidity, CO2 ,OCC and Zigbee options
Sales Price Discount Price OEM>50k/yr
Tstat6 39 37 36
Tstat6-CH 44 42 41
TSTAT6-CO2 90 75 60
TSTAT6-ZIGB 55 53 51
TSTAT6-OCC 41 39 38

Tstat Series
- 2 -
Tstat6 Technical Data
Tstat6-CO2 Technical Data
- Tstat6 with C02 sensor now available. All the powerful features of Tstat6 zone controller
plus a C02 sensor in one compact package.
- Can be used as a stand alone zone controller for ‘demand based’ total solution.
- Or use the analog outputs as a regular C02 transmitter as inputs to a central controller.
- Modbus RS485 network connection for easy integration with automation systems.
- Tight control of 0.5°C provides comfortable indoor environment.
- High impact plastic enclosure provides durability in commercial environments.
- Customizable sequence of operation table (FCU with modulating or on/off valve, single
or 3-speed fan, pressure independent VAV, stage sequencer…)
- An affordable CO2 sensing solution for HVAC/DCV
CO2 Performance:
Measurement Range..................................................................0-3,000 ppm display
(2000ppm, 5000ppm, 10,000ppm are optional)
Accuracy....................................................................................±70 ppm or ±5% of reading
Repeatability..............................................................................±20 ppm
Temperature Dependence ........................................................Typ.±0.2% of reading per °C or ±2 ppm per
°C, whichever is greater, referenced to 25°C
- 2.4-GHz IEEE 802.15.4 Compliant RF Transducer
- Programmable Output Power Up to 4.5dBm
Tstat6-Zigbee Technical Data
TSTAT6 5 relays x 2amps @24V, 7 analog inputs,
2 analog outputs (10V @100ma)
Operating temperature -30-70°C(-22~158°F)
Supply voltage 12~24VAC/DC ±20%, 50-60Hz
Power consumption 100mA at 12VDC
Relay contacts rating 2A @ 24VDC, 0.5A @ 125VAC
UL File No.: E43149
CSA File No.: LR26550
Ambient humidity 10-90 %Rh
Operating Environment 0 ~ 99% humidity non condensing
Plastic Housing Flammability rating UL 94V0 file E194560
Enclosure rating IP31
Temperature sensor 10K thermistor ±0.5°C
Colour White/Off-white
Weight 200g

Tstat Series
- 3 -
A genuine Tstat6 with Clock or Humidity options, they added some new features.
1. Temperature range: indoor & outdoor -30 °C ~ + 70 °C ( -22 ~ +158 °F )
Humidity range : indoor 10% ~ 90%RH
Power - supply : 100mA at 12VDC
2. Functions :
Indoor & outdoor temperature display , indoor humidity display.
Temperature unit °C /°F changeable.
Clock & date display function , automatic exchanging in 5 seconds between clock & date
Pointing function each hour.
Display the current temperature , humidity , time, and automatic exchanging working according
to the schedule.
Calender display function.
Week display function.
Clock ,date , lunar calendar, Gregorian calendar automatic exchanging function (only for typical
models).
3. Attention :
*Press button for one time when the meter is first used or the battery is replaced .
*Press button for one time if any abnormal display appears .
Tstat6-C or Tstat-CH Technical Data
Tstat6-OCC Technical Data
Tstat6-OCC is an energy conservation device designed to detect the presence of human occu-
pants in a given area.
Many commercial, industrial and government facilities require a significant number of lighting fix-
tures for adequate illumination, and therefore use a significant amount of power to operate the lighting
fixtures. A number of facilities use lighting control systems to control when the lighting fixtures are en-
ergized and thereby reduce the amount of power that is consumed to light these facilities.
Tstat6-OCC can be provided with an ambient light sensor and control input therefore. The ambi-
ent light sensor and control input can be used to select a minimum level of light above which a lighting
fixture is prevented from being switched and powered on following detected motion.
Tstat6-OCC typically sense the presence of one or more persons within a designated area and
generate occupancy signals indicative of that presence. These signals activate or deactivate one or
more electrical appliances, such as, for example, a lighting unit or a heating, ventilating, and air con-
ditioning system. When occupancy is sensed, the various electrically-powered loads in that area con-
trolled by the sensor are energized. When that same area has been unoccupied for a predetermined
period of time, the sensor de-energizes the electrical loads that it controls. Thus, the lighting control
system operates in a daylight inhibit mode when the ambient light level is sufficient to render the switch-
ing of the lamp unnecessary. The two most prevalent types of occupancy sensors are passive infrared
and active ultrasonic devices. A passive infrared (PIR) sensor will turn on the load whenever it detects
a moving or newly apparent heat source. we only have passive infrared (PIR) sensor.

Tstat Series
- 4 -
Light Sensor Module Technical Data
The light Sensor module is a standard item now. It just provides an illuminance value. It is de-
signed with TPS851. This device enables low power consumption to be achieved.
• Little fluctuation in light current and high level of sensitivity
: IL = 37 μA to 74 μA @EV = 100 lx using fluorescent light
: Light current variation width: ×1.67
(When light current classification is specified.)
: Little temperature fluctuation
• Built-in luminous-efficiency correction function, reduced sensitivity variations due to vari-
ous light sources
: IL (using incandescent light)/IL (using fluorescent light) = 1.2 (typ.)
• Low supply voltage, making device suitable for battery-powered equipment: VCC = 2.7
V to 5.5 V
Operating Temperature: -30°C ~ 85°C
Maximum Ratings (25°C)
Characteristics Symbol Rating Unit
Supply voltage VCC -0.5 to 7 V
Output voltage VOUT ≤VCC V
Light current IL 5 mA
Permissible power dissipation P 35 mW
Operating temperature range Topr -30 to 85 °C
Storage temperature range Tstg -40 to 100 °C
Soldering temperature range
(Note 1) Tsol 260 °C
Note 1: The reflow time and the recommended temperature profile are shown in the section entitled
Handling Precautions.
Recommended Operating Conditions
Characteristics Symbol Min Typ. Max Unit
Supply voltage VCC 2.2 —— 5.5 V

Tstat Series
- 5 -
Note 2: CIE standard A light source is used (color temperature 2856K, approximated incandescence
light).
Note 3: Fluorescence light is used as light source. However, white LED is substituted in a mass-pro-
duction process.
IL classification IL (3) A: - > 37 μA to 62 μA, B: 44 μA to 74 μA
Note 4: Light current measurement circuit
Electrical and Optical Characteristics (Ta 25°C)
Characteristics Symbol Test Condition Min Typ. Max Unit
Supply current ICC VCC =3 V, EV=1000 lx
RL =1 k Ω(Note
2)
— 620 — μA
Light current (1) IL (1) VCC =3 V, EV=1000 lx
(Note 2) ,
(Note 4)
—62 — μA
Light current (2) IL (2) VCC =3 V, EV=10 lx
(Note 3) , (Note 4) 3.7 — 7.4 μA
Light current (3) IL (3) VCC =3 V, EV=100 lx
(Note 3) , (Note 4) 37 — 74 μA
Light current ratio IL (1)
——
IL (3)
—— — 1.2 1.7
Dark current ILEAK VCC=3.3 V, EV = 0 — — 0.17 μA

Tstat Series
- 6 -

Tstat Series
- 7 -

Tstat Series
- 8 -
Switching Time Measurement Circuit and Waveforms

Tstat Series
- 9 -
Tstat6 Highlights

Tstat Series
- 10 -
Tstat6 Jumper Settings
Tstat6 Wiring Diagram
Ce manuel convient aux modèles suivants
3
Table des matières
Manuels Thermostat populaires d'autres marques

EWELLY
EWELLY EW-181 Manuel utilisateur

Prolon
Prolon T1100 Instructions d'installation

Computherm
Computherm Q20 Manuel utilisateur

Heatmiser
Heatmiser neoStat Manuel utilisateur

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manuel utilisateur

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manuel utilisateur