Fox Electronics GSM52S Manuel utilisateur

CONTENTS
Texecom Serial SMS Communicator
Quick Start Guide
1) SIM Card Setup
) Texecom 412/816/832 Com Port Setup 2
3) Communicator Connection
4) Communicator Start Up
) Important Notes for SMS Commands. 5
6) Master User Setup
7) Add System User Numbers
8) ARM/DISARM/RESET Panel
9) Bypass Panel Zones
10) Set up Partition Profiles
11) Request Panel or Communicator Status
12) Troubleshooting
INPUT
1 2 3 4 OP1 OP2
NO/C COM
POS NEG
12V DC
PWR
PGM
NO NC
SIM
SIM 2
SIM
SIM 1
FOX
GSM52S
SIGNAL
STAT
SERIAL
PLEASE MAKE SURE THAT THIS MANUAL IS FOR THE
SOFTWARE VERSION OF THE COMMUNICATOR IN USE

SIM SIM SIM SIM SIM
SIM
SIM
SIM
SIM
SIM
1) SIM Card Setup
-Firstly, make sure you have a SIM Card that is active and can make calls and send
SMS’s.
-Record the Cell Number of the SIM Card you will be using for the Communicator.
OPTION 1-SIM PIN UNSECURED OPTION 2-SIM PIN SECURE
Step1: Insert SIM Card into Cell phone and make Step1: Insert SIM Card into Cell phone and make
REMOVE PIN CODE REQUEST. SIM PIN ‘0000’.
NB: SIM PIN options on Cell phone NB: SIM PIN options on Cell phone
Settings>Security>SIM Card Lock. Settings>Security>SIM Card Lock.
Step2: Remove the SIM from the Cell phone and Step2: Remove the SIM from the Cell phone and
and insert it into SIM1 on the GSM52s. and insert it into SIM1 on the GSM52s.
Selecting the ’SIM PIN Secure’ option will cause the SIM PIN to be automatically encrypted by the
Communicator and will need the Command ‘.RS’ to be sent in order to remove the SIM.
If DUAL SIM cards are installed SIM1 will be the first network accessed and SIM2 the backup.

TEXECOM 412/816/832 PANEL
Com 2
T R T1 R1
W08
2200uF
Com 1
8765
4321
AUX
INP
Z8Z7Z6Z5
Z4Z3Z2
COM
Z1
COM
COM
COM
Aux12V
+ -
Sir/Spk
+ -
Network
+ - T R
A.C. Batt
+-
4Menu 9
Scroll UP/DOWN until Value = 000 Yes
Scroll UP/DOWN until Value = 000 Yes
23
765
76 9
Programming Menu
Enter Code > ??
Com1 Device Type
Enter Value: 000
Com2 Device Type
Enter Value: 000
2) Texecom 412/816/832 Com Port Setup
To set up the Texecom Panel for EVENT REPORTING,
ensure the that the following settings on Panel are set.
First Check which Com Port has been
connected to the Communicator:
Enter programming menu (Default code used)
If connecting to Device Type = 000(PC-Com)Com1
if connecting to Device Type = 000(PC-Com)or Com2

Com Port Successfully
Connected & Time
Synced.
RECEIVED
.,!
GHI
ABC DEF
JKL
MNO
PQRS TUV WXYZ
0#
X
CELL PHONE
SMS +27721234567
Set UDL Passcode:
Makes the UDL Passcode ‘1234’.
Enable Battery Monitoring:
IF REQUIRED
Enable Battery Load test &
Connection Supervision:
Exit Programming:
The setup is only done once. When the Master user is programmed, you will receive an SMS indicating
that the Serial Communication between the Panel and Communicator was successful after a powerup.
The communicator will with the network provider downloaded time.auto Sync the time
2 2 34Yes
3
Menu 6Make sure 6 is ON. Yes
3Make sure 2&3 are ON. Yes
3
9 9
Master User.
Download Menu
Enter Option 0-9
Passcode1234
Download Menu
Enter Option 0-9
Programming Menu
Enter Code > ??
Programming Menu
Enter Code > ??

3) Communicator Connection
Connect the GSM52S SMS Communicator
with the serial cable supplied to Texecom
412/816/832 Alarm Panel as per the
following diagram
Fig 1.
TEXECOM 412/816/832 PANEL
Com 2
T R T1 R1
W08
2200uF
Com 1
8765
4321
AUX
INP
Z8Z7Z6Z5
Z4Z3Z2
COM
Z1
COM
COM
COM
Aux12V
+ -
Sir/Spk
+ -
Network
+ - T R
A.C. Batt
+-
Fig 1
12v 7Ah Battery
The DC 12v power
directly is supplied
by the Serial Cable
from the Alarm Panel
SERIAL port on
Com1 OR Com2l.
Fox to Texecom
SERIAL/POWER Cable
INPUT
1 2 3 4 OP1 OP2
NO/C COM
POS NEG
12V DC
PWR
PGM
NO NC
SIM
SIM 2
SIM
SIM 1
FOX
GSM52S
SIGNAL
STAT
SERIAL

4) Communicator Start Up
With the SIM Card inserted and the Communicator DC 12V
power connected you will notice that the SIGNAL LEDs
run up and down and the flashes fast.PWR LED
This is the Normal Startup
procedure, it will continue like
this until the communicator is
registered on to the network.
You should notice that the SIGNAL LEDs STOP running
and the UPPER SIGNAL LED stays illuminated.
Every 10 seconds the signal LEDs will change to indicate
the signal level.
You are now ready to Learn the Master User.
INPUT
1 2 3 4 OP1 OP2
NO/C COM
POS NEG
12V DC
PWR
PGM
NO NC
SIM
SIM 2
SIM
SIM 1
FOX
GSM52S
SIGNAL
STAT
SERIAL

5 mportant Notes for SMS Commands.) I
1. ALL Commands and custom Partition Phrases start with a ‘.’(Full stop)MUST
2. There Must be between the initial ‘.’(Full stop) and the command.NO SPACE
3. There Must be only a between a command and data.SINGLE SPACE
4. Commands are .CASE-SENSITIVE
5. Only a SINGLE Partition Phrase with per SMS is valid.ON/OFF/STAY
6. Please do not Include the words ‘ ’, ’ ’, ’ ’ or ‘ ’ in a CustomON OFF RESET STAY
Partition profile phrase.
7. Multiple setup SMS and Advanced SMS Command options are available to
execute various actions and settings. Please refer to the
‘SMS52S_AIR_TEXE_Command_Listxxxxx.pdf’ file for the latest commands.

6 Master User Setup)
The Communicator must have a valid Master User learnt in memory that allows
access to programming. The Communicator uses this Cell phone Number to validate
setup programming commands. NB: Enable SMS Delivery Reports to see that the commands
deliver to the Communicator.
From the Cell number you wish to use as the Master User, SMS the
Following:
From Master user SMS:
.M1#
To the Cell Number of
the SIM you inserted
into the Communicator.
Master User
added.
RECEIVED
.M1#
SENT
.,!
GHI
ABC DEF
JKL
MNO
PQRS TUV WXYZ
0#
X
CELL PHONE
SMS +27721234567 This Command will add the number
of the sender as the andMaster User
will reply with an SMS confirming the
action.

7 Add System User Numbers)
The GSM52S Serial Communicator can store up to 50 Cell phone numbers.
The stored numbers will receive SMS Messages for valid events on the serial port as well as input
activations. .if the wants to receive activations, the number must also be added hereMaster User
Please note, all numbers must be entered in INTERNATIONAL FORMAT.
ie. +27xxxxxxxxx. For South African subscribers.
To add the Number 072 123 4567 which
is a South African Subscriber,
From Master User SMS:
.A +27721234567#
The newly added user is now ready to receive SMS
events from the Communicator, Activate Outputs and
Send Panel Commands.
Multiple Users may be added in one SMS by replacing
the consecutive number command with .A *A
USER Number
Successfully added:
+27721234567.
RECEIVED
.A +27721234567#
SENT
.,!
GHI
ABC DEF
JKL
MNO
PQRS TUV WXYZ
0#
X
MASTER CELL PHONE
SMS +27xxxxxxxxx
Your Number was
added at GSM52S.
SMS Communicator.
RECEIVED
.,!
GHI
ABC DEF
JKL
MNO
PQRS TUV WXYZ
0#
X
USER CELL PHONE
SMS +27xxxxxxxxx
Master User.
Newly Added User.

8 and Alarm ) ARM/DISARM RESET Panel
The Communicator can be used to Arm, Disarm, Stay Arm or Reset the Panel. A standard
command phrase, ‘ ’ can be used that will apply to ALL available Partitions(ie 1-4).System
Note: Up to 8 Custom Phrases can also be added. Section 10 explains how.
To ARM( ) the alarm Panel: To the alarm Panel:ON RESET
From any user SMS: From any user SMS:
.System ON# .System RESET#
OFF STAY To Disarm( ) the alarm Panel: To Arm the alarm Panel:
From any user SMS: From any user SMS:
.System OFF# .System STAY#.
Table des matières