Forward STM-8800 Manuel utilisateur

FULLHDComboFinderMeter
STM-8800
HDDVB-S2/S+DVB-T2/T+Spectrum
Meter
Usermanual

STM8800
2 |ENG
Table of Contents
Description....................................................................................................... 4
Safety instructions........................................................................................... 4
Safety of persons............................................................................................... 4
General information.......................................................................................... 4
Appropriate Usage.......................................................................................... 5
Delivery range................................................................................................. 5
Device overview............................................................................................... 6
Start of operation.............................................................................................8
Battery.............................................................................................................. 8
Switch-on the Device........................................................................................ 8
Lithium-ions-battery....................................................................................... 9
Charging the battery.......................................................................................... 9
Storing of the batteries...................................................................................... 9
System setting................................................................................................ 10
Language Setup............................................................................................ ...10
Factory Default.................................................................................................11
Factory reset................................................................................................. ...11
Factory reset.................................................................................................. 11
Satellite finding ............................................................................................. 12
Finding channels manual ................................................................................ 12
Lining satellite aerial up.................................................................................. 13
T/T2 finding................................................................................................... 14
Finding channels manual …...................................... ........................... .........14
Lining T/T2 antenna up --------------------------------------------------------------15
Installation ----------------------------------------------------------------------------16
Satellite setting----------------------------------------------------------------------------16
Dish Set up---------------------------------------------------------------------------------16
DiSEqC Setup-----------------------------------------------------------------------------17
USB--------------------------------------------------------------------------------------19
File Viewer----------------------------------------------------------------------------------19
Updating-------------------------------------------------------------------------------------20
Backup Data---------------------------------------------------------------------------------20

STM8800
3 |ENG
Angle calculation........................................................................................... 21
Spectrum........................................................................................................ 21
AV Setup........................................................................................................ 21
Disposal.............................................................................................. ............24
Technical specifications...................................................................... ..........25
Warrenty............................................................................................ ............26

STM8800
4 |ENG
Description
The Satellite meter is a handy digital antenna measuring device for an quick
and easy alignment of satellite antennas. If a satellite is found, the meter
shows it on the display and emits a audible signal. Signal strength and quality
are displayed as numerical values and bar graphs. Another measurement
value is the forward error correction (FEC) and the bit error rate (BER),
Modulation error rate(MER),In addition, the picture quality can be revised on the
high-resoluted 4.3-inch TFT LCD screen. Many satellites are pre-programmed in
order to an quick antenna adjustment.
The scope of supply contains, among the charger, an USB connector which allows
you to update software.
A carrying case serves as protection and for the transport. It cares for better
readability of the display at sunshine.
Safety instructions
Attention!
Please read the safety instructions carefully before operating
the device.
Please follow all warnings and instructions on the equipment and
in the operating manual.
Safety of persons
Ensure that nobody can be hurt by falling tools or parts of the satellite
antenna during the adjustment and installation of the antenna. For your own
security use a rope on sloping roofs.
General information
Attention!
The devise should only be operated with the supplied AC
adapter at the mains.
Do not open the meter or the included AC adapter. There is
danger of life through electric shock!
Wrong usage of the ports can lead to the destruction of the
measuring device.

STM8800
5 |ENG
Proceed carefully with the measuring device:
Avoid low temperatures (below 0 °C) or to high humidity.
The TFT display can be damaged by mechanical impacts.
Avoid excessive input voltages.
Do not operate with the device:
if it has visible damage,
if there are loose parts in the device,
if the device was located outdoors or in damp rooms a extended period of time.
Appropriate Usage
The measuring device meter was developed to measure signals of
digital satellite antennas and satellite systems. It is exclusively for this purpose
and should only be used for this purpose. Use the equipment only for the
purpose, which is described in this manual.
Follow all information in this manual, particularly the safety instructions on
page 4
Any other usage is rated as not properly and can result in damage or even injury.
There will be no liability for damages caused by a non-intended use.
Delivery range
Please check if the delivery is complete.
Included in delivery:
Tool case
device meter
a carrying bag
an extern charger
an power cable
AV cable
F connnector
an user manual CD
If the delivery should be incomplete, contact your specialist dealer

STM8800
6 |ENG
Device overview
LNB IN : Connect this port to the satellite atn cable
RF IN: Not connect
DC 14V: Power supply port
AV OUT: Connect this port to TV’S CVBS via AV cable
HDMI: Connect this port to TV HDMI port via HDMI cable
AV IN: Connect the port to other’s CVBS Cable

STM8800
7 |ENG
Figure: Front of the meter
No. Description
1 LNB1-IN
LNB2-IN
Digital satellite signal input
2 LC-Display Display of the TV picture, the menu and the
measured values
3 POWER-LED
Display of the energy state:
Operation:
red: the measuring devise is switched on.
Off: the measuring devise is switche
d off.
In charge:
Green: The battery is charged
Red: The battery is full charged
4 LOCK-LED LED lights when a signal is received.
5 FUNCTION keys
F1: shortcut key
F2: shortcut key
F3: shortcut key
F4: shortcut key
5.1 22K/13V/18V-L
EDs
Lights if 22K/13V/18V signals are received
6
6.1
Navigation-cross
OK
Navigation through menus,
switching programs ▲, ▼
volume control ◄, ►
OK button: confirmation of a selection
7 Numeric keys Direct enter of numbers

STM8800
8 |ENG
8 FIND FIND menu: for a quick and easy alignment of
a satellite antenna
9 Menu Display the main menu
10 AV Switch AV input or out put setup
11 ANGLE Display the calculation menu
12 SYSTEM Configuration of all system parameter.
Display current AV setup.
13 POWER Switch on the power on at 2-3 second
14 SCAN Display the auto scan menu
15 OFF Switch off the power
16 T/R Switch the TV or Radio program display
17 SPTRUM Display the menu of spectrum (for spectrum
meter only)
Start of operation
Battery
Before the first operation with the measuring device charge the battery completely. (see also
chapter “Lithium-Ion battery” on page 10).
Load the accumulator during the first loading procedure at least 5
hours.
The maximum battery charging time is approximately 12 hours.
Switch-on the Device
ðPress 2-3 seconds the red power button on the meter.

STM8800
9 |ENG
Lithium-ions-battery
Explosion danger!
Never the two poles (+ and -) connect with each other!
Attention!
Storing or operating accumulator no more than 40° C.
Not burning or damaging accumulator.
Not taking accumulator to contact with water.
Charging the battery
The maximum battery charging time is approximately 12 hours.
A charging circuit in the measuring device provides an optimal charge of the
battery. The device is charged if it is switched off.
èTurn the device off, if it is not already off.
èConnect the Euro-main cable with the external AC adapter.
èConnect the external AC adapter to the power grid.
èConnect the AC adapter to the low-voltage port at the bottom.
èThe battery is charged as soon as you connect theAC adapter to the
meter
The Power-LED shows the battery status:
Red: the battery is charged
Green: the battery is completely loaded
Storing of the batteries
Storing the batteries between 0° Celsius and 40° Celsius.
Loading the accumulator at a longer storage every two weeks to
avoid a depth discharge.

STM8800
10 |ENG
System setting
èPress the MENU button.
èSelect the point system setting.
èConfirm your selection using the OK button.
Figure 2: System setting
language Setup
Press the SYSTEM button to change the menu language.
_Select the point Language setup.
_Choose your desired language using the ◄- or ►- button.
_After your selection press the EXIT button and follow the instructions on.
Table des matières
Autres manuels Forward Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur
















