Forma Scientific 3158 Manuel utilisateur

Forma Scientific, Inc.
P.O. Box 649
Marietta, Ohio 45750
Telephone: (740) 373-4763
Telefax: (740) 373-4189
________________________________________
Models:
Single Chamber 3158, 3164, 3154, 3166
Dual Chamber 3326, 3336, 3354
Water Jacketed Incubator
Manual No. 7063158
Important!
Read this instruction manual.
Failure to read, understand and follow the instructions in this manual may result in
damage to the unit, injury to operating personnel and poor equipment performance.
Caution: All Internal Adjustments And Maintenance Must Be Performed By
Qualified Service Personnel.

Forma Scientific, Inc.
NOTE:
The material in this manual is for information purposes only. The contents and
the product it describes are subject to change without notice. Forma Scientific, Inc.
makes no representations or warranties with respect to this manual. In no event shall
Forma Scientific, Inc. be held liable for any damages, direct or incidental, arising out
of or related to the use of this manual.
MANUAL NO. 7063158
- N/A 8/9/96 Add gas guard drawings/parts list per B. Purvis
0 --- 7/17/96 Updated calib. Procedures, Section 7 heg
0 IN-2009 11/15/95 Release 5, added CE Mark
REV ECN DATE DESCRIPTION

Forma Scientific, Inc.
GENERAL SAFETY NOTES
The Occupational Safety and Health Administration (O.S.H.A.) has revised Section
1910-147, The Control Of Hazardous Energy (Lockout/Tagout).
Hazardous energy may be: electric, air, hydraulic, water, steam, gravity, spring & all other
equally hazardous energy.
This revised regulation, states that you will de-energize all potential sources of energy
(may be more than one energy source) prior to performing service or maintenance on any
equipment. It also states that a lock shall be placed on the de-energized control, along
with a verified test (use of a voltmeter or other equipment) to insure no accidental starts.
If you are not familiar with this regulation, review the O.S.H.A. Regulation, Section
1910-147.
In field service, full compliance with this regulation is difficult at best.
Troubleshooting must often be performed with hazardous energy applied; therefore
extreme caution must be followed during these troubleshooting steps. Only Qualified
Personnel Must Perform This Work. This phase of the repair work must be coordinated
through the customer's facilities maintenance department or designated person.
When performing service or maintenance as an outside contractor/worker, follow the
Outside Work Force's Lockout/Tagout system. Be alert for new types of lockout/tagout
devices.
√Always use the proper protective equipment (clothing, gloves, goggles etc.).
√Always dissipate extreme cold or heat, or wear protective clothing.
√Always follow good hygiene practices.
√Each individual is responsible for his/her own safety.
For your safety adhere to all DANGER and CAUTION statements.
Danger: This word is used to call attention to immediate hazards of
equipment or conditions which, if not avoided, could result in personal
injury, loss of life or property damage.
Caution: This word is used to call attention to potential hazards of
equipment or conditions which, if not avoided, could
result in personal injury, loss of life or property damage.

Forma Scientific, Inc.
Table of Contents
Page
Section 1 - Receiving
1.1 Preliminary Inspection ......................................................................... 1-1
1.2 Visible Loss or Damage ....................................................................... 1-1
1.3 Responsibility for Shipping Damage .................................................... 1-1
Section 2 - Unpacking List
2.1 Unpacking List..................................................................................... 2-1
Section 3 - Introduction
3.1 The Water Jacket: Key Features .......................................................... 3-1
Section 4 - Installation and Start-Up
4.1 Location............................................................................................... 4-1
4.2 Preliminary Disinfecting ...................................................................... 4-1
4.3 Installing the #6 Neoprene Stopper (Access Port) ................................ 4-2
4.4 Installing the Shelf Brackets and Cam Latch to the Duct Sheets........... 4-2
a. Installing the Shelf Brackets......................................................... 4-2
b. Installing the Cam Latch Assembly.............................................. 4-2
4.5 Installing the Duct Sheets..................................................................... 4-4
4.6 Installing the Shelves ........................................................................... 4-4
4.7 Leveling............................................................................................... 4-4
4.8 Connecting the Incubator to a Power Source ........................................ 4-5
4.9 Preparing the Incubator for Filling ....................................................... 4-5
4.10 Filling the Water Jacket ...................................................................... 4-7
a. Funnel Method............................................................................. 4-7
b. Tap Fill Method ........................................................................... 4-8
4.11 Connecting the Optional Gas Guard ................................................... 4-9

Forma Scientific, Inc.
Page
4.12 Connecting the Gas Supply without the Gas Guard ............................. 4-10
4.13 Filling the Humidity Reservoir or Pan................................................. 4-11
4.14 Setting the Chamber Temperature ....................................................... 4-12
4.15 Setting the Over Temp Safety Thermostat ........................................... 4-13
4.16 Zeroing the CO2Controller................................................................. 4-14
4.17 Setting the CO2Content .................................................................... 4-15
Section 5 - Operation
5.1 Operation ............................................................................................. 5-1
5.2 Overview of Humidification and CO2................................................. 5-1
5.3 Control Panel ....................................................................................... 5-2
a. Fill Fitting and Vent Hole ............................................................ 5-2
b. Power Switch and Pilot Light....................................................... 5-3
c. Circuit Breaker............................................................................. 5-3
d. Variable/37°C Switch, Temp Control and Heater Pilot Light ....... 5-3
e. Gas Sample Port........................................................................... 5-4
f. Setpoint Adjustment Tool............................................................. 5-4
5.4 (Factory-Installed Option) Gas Guard Stock #190410 ......................... 5-4
a. Control Switch ............................................................................. 5-5
b. Silence Switch ............................................................................. 5-5
c. Gas Depletion Alarm.................................................................... 5-5
d. Active Tank Indicating Lights...................................................... 5-5
e. Pressure Low Indicating Lights .................................................... 5-6
5.5 CO2Module ........................................................................................ 5-6
a. CO2Power Switch ....................................................................... 5-6
b. CO2Controller and Digital Display............................................. 5-7
c. Audible CO2Alarm and Pilot Light ............................................. 5-7
d. SET/SILENCE Push Button......................................................... 5-7
e. Alarm Disable Switch .................................................................. 5-7
f. CO2Inject Light.......................................................................... 5-8
g. CO2Zero Adjustment .................................................................. 5-8
5.6 Alarm/Monitor Module ........................................................................ 5-8
a. Over Temperature Controller and SET/SILENCE Button............. 5-8

Forma Scientific, Inc.
Page
b. Over Temperature Alarm and Pilot Light ..................................... 5-9
c. Add Water Pilot Light and Audible Alarm ................................... 5-9
5.7 Remote Alarm Relay System................................................................ 5-9
5.8 Recorder Output................................................................................... 5-11
Section 6 - Routine Maintenance
6.1 Installing the Decontamination Kit....................................................... 6-1
6.2 Disinfecting the Incubator Interior ....................................................... 6-3
6.3 Cleaning the Cabinet Exterior .............................................................. 6-4
6.4 Draining the Water Jacket .................................................................... 6-4
6.5 Changing the CO2Filter ...................................................................... 6-5
6.6 CO2Test Instruments .......................................................................... 6-5
Section 7 - Service (For Qualified Personnel Only)
7.1 General Troubleshooting...................................................................... 7-1
7.2 CO2Control Module Calibration ......................................................... 7-4
a. Minor CO2Calibration ................................................................ 7-4
b. Complete CO2Control Calibration.............................................. 7-5
7.3 37C° Control Calibration ..................................................................... 7-9
7.4 Calibrating the Temperature Monitor ................................................... 7-9
7.5 Replacing the CO2Sensor ................................................................... 7-10
7.6 Replacing the Triac .............................................................................. 7-10
7.7 Replacing the CO2Solenoid ................................................................ 7-11
7.8 Replacing the Temperature Control...................................................... 7-11
7.9 Replacing the Pilot Lights.................................................................... 7-12
7.10 Replacing the Thermistor ................................................................... 7-12
7.11 Replacing the 0.3 Amp Fuse................................................................ 7-12
7.12 Replacing the Blower Motor ............................................................... 7-13
a. Single Units ................................................................................ 7-13
b. Stacked Units.............................................................................. 7-14

Forma Scientific, Inc.
Section 8 - Specifications
Section 9 - Auxiliary Equipment
Section 10 - Parts List
Section 11 - Schematics
Section 12 - Warranty Information

Forma Scientific, Inc.
___________________________________________________________________________
1-1
SECTION 1 - RECEIVING
1.1 PRELIMINARY INSPECTION
This incubator was thoroughly inspected and carefully packed prior to shipment and all
reasonable precautions were taken to ensure safe arrival of the merchandise at its
destination. Immediately upon receipt, before the unit is moved from the receiving area,
carefully examine the shipment for loss or damage. Unpack the shipment and inspect both
interior and exterior for any in-transit damage.
1.2 VISIBLE LOSS OR DAMAGE
If any loss or damage is discovered, note any discrepancies on the delivery receipt.
Failure to adequately describe such evidence of loss or damage may result in the carrier
refusing to honor a damage claim. Immediately call the delivering carrier and request that
their representative perform an inspection. Do not discard any of the packing material and
under no circumstances move the shipment from the receiving area.
1.3 RESPONSIBILITY FOR SHIPPING DAMAGE
For products shipped F.O.B. Marietta, Ohio, the responsibility of Forma Scientific,
Inc. ends when the merchandise is loaded onto the carrier's vehicle. On F.O.B.
Destination shipments, Forma Scientific's and the carrier's responsibility ends when your
Receiving Department personnel sign a free and clear delivery receipt.
Whenever possible, Forma Scientific, Inc. will assist in settling claims for loss or in-
transit damage.

Forma Scientific, Inc.
__________________________________________________________________________
2-1
SECTION 2 - UNPACKING LIST
2.1 UNPACKING LIST
Remove the packing box from the incubator. If the unit is to be moved by fork lift,
leave the incubator on the skid until it has been moved to its designated location. A
plastic bag containing the following accessories is packed inside the incubator:
Qty. Stock # Description Purpose
1 190028 Decontamination Kit Maintenance
1 180001 Polypropylene Funnel Fill & Drain
3' 246011 Vinyl Tubing 3/8" ID Fill & Drain
6' 246010 Vinyl Tubing 3/16" ID CO2 Connection
1 285057 Extender Card Maintenance & Calibration
Also packed with each incubator:
Qty. Stock # Description
24 23052 Stainless Steel Wing Nuts (#10-32)
20 55000 Stainless Steel Screws (Truss Head #10-32" x 5/8")
1121034 Cam Latch (Nylon)
1127019 Stainless Steel Spacer (1/4" Diameter x 9/16")
1550017 Stainless Steel Screw (Truss Head #8-32" x 1")
123051 Stainless Steel Wing Nut (#8-32)
5224140 Stainless Steel Shelves
1600034 Snapper Hose Clamp (.375")
43113234 Shelf Brackets
13113224 Stainless Duct Channel, Top
13113222 Stainless Duct Sheet, Left
13113223 Stainless Duct Sheet, Right
1130038 #6 Neoprene Stopper
1190388 Telephone Line Cord, 12'
1190392 Modular RJ-11 Jack
17053158 Instruction Manual

Forma Scientific, Inc.
_________________________________________________________________________
3-1
SECTION 3 - INTRODUCTION
3.1 THE WATER JACKET: KEY FEATURES
The Forma Scientific Model 3158 water jacketed incubator is designed to meet the
stringent requirements of today's modern laboratory and is a combination of economy,
accuracy and reliability.
The Model 3158 Incubator features:
•Ultra-flat, vibration-free shelves to provide optimum culturing
conditions.
•Direct-set CO2, temperature, and over temperature alarm set points..
•Digital readout of temperature and CO2levels in the chamber.
•A sealed chamber to minimize CO2consumption.
•A sealed water jacket to minimize water evaporation.
The 3158 water jacket incubator is designed for easy and convenient servicing by
providing:
•Front access to all components so that the unit need not be moved for
service, repair, or routine maintenance.
•A slide-out control panel for easy access to electrical components.
•Plug-in CO2, and Temperature/Alarm modules to facilitate servicing or
replacement.
•Self-diagnostic switches in the control modules to aid in
troubleshooting the system and localizing problems.
•Minimal unit down-time to disinfect the water jacket.
Autres manuels pour 3158
1
Ce manuel convient aux modèles suivants
6
Table des matières
Autres manuels Forma Scientific Accessoires

Forma Scientific
Forma Scientific 3950 Manuel utilisateur

Forma Scientific
Forma Scientific 3920 Mode d'emploi

Forma Scientific
Forma Scientific 3250 Manuel utilisateur

Forma Scientific
Forma Scientific 3546 Manuel utilisateur

Forma Scientific
Forma Scientific 310 Series Mode d'emploi

Forma Scientific
Forma Scientific 3920 Mode d'emploi

Forma Scientific
Forma Scientific 3980 Manuel utilisateur

Forma Scientific
Forma Scientific 3980 Manuel utilisateur

Forma Scientific
Forma Scientific 3940 Manuel utilisateur

Forma Scientific
Forma Scientific 3940 Mode d'emploi