Follett U150 Mode d’emploi

206563R02
801 Church Lane • PO Box D, Easton, PA 18044
Toll free (800) 523-9361 • (610) 252-7301
Fax (610) 250-0696 • www.follettice.com
Operation, Service and Parts Manual
U150 Series
Ice Dispensers
U150
U150B
U150N U150NR4A/W
U150NR5A/W
U150NR8A/W
U150NR10A/W
U150R4A/W
U150R5A/W
U150BR4A/W
U150BR5A/W
U150R8A/W
U150R10A/W
U150BR8A/W
U150B10A/W
Order parts online
www.follettice.com

Welcome to Follett
Follett ice dispensers enjoy a well-deserved reputation for excellent performance, long-term reliability and
outstanding after-the-sale support. To ensure that this dispenser delivers that same degree of service, we ask
that you take a moment to review this manual before using the dispenser. Should you have any questions or
require technical help at any point, please call our technical service group toll free at (800)523-9361 or
(610)252-7301.
Before you begin
Check your paperwork to determine which model you have. Following is an explanation of the different model
numbers in the U150 series.
Electrical specifications
Standard electrical - 115V, 60Hz, 1 phase
Separate circuit and disconnects required for each icemaker and
dispenser. Max. fuse size 20 amps per circuit
Manual load models
U150N – dispenser 2.4 amps
U150 – dispenser 2.4 amps
U150B – dispenser 4.4 amps
Models with R4A/W Icemaker
U150R4A/W, U150NR4A/W – 13.4 amps
U150BR4A/W – 15.4 amps
U150R8A/W, U150NR8A/W – 24.4 amps
U150BR8A/W – 26.4 amps
Models with R5A/W Icemaker
U150R5A/W, U150NR5A/W – Icemaker 11.0 amps, dispenser 2.4
amps
U150BR5A/W – Icemaker 11.0 amps, dispenser 4.4 amps
U150R10A/W, U150NR10A/W – (2) icemakers 11.0 amps each,
dispenser 2.4 amps
U150B10A/W – (2) icemakers 11.0 amps each, dispenser 4.4
amps
• Equipment ground required.
• Separate circuit and disconnects required for each icemaker
and dispenser. Disconnects suggested within 10 ft (3m) of
dispenser and icemaker(s).
U150BR5A
Condenser type – A = air-cooled, W = water-cooled
Remote icemaker(s) capacity and refrigerant – 4 = 400 lbs (181kg)/day, R12;
5 = 400 lbs (181kg)/day, R22; 8 = 800 lbs (363kg)/day, R12; 10 = 800 lbs
(363kg)/day, R22
B = with integral beverage cooling. Absence of a B = no integral beverage
cooling. N = no beverage rail or valves.
Approximate storage capacity in lbs
Dispenser configuration – U = undercounter
Important cautions
• Storage area of dispenser contains mechanical, moving parts. Keep hands and arms clear of
this area at all times. If access to this area is required, power to unit must be disconnected first.
• Follett manual load units can accommodate most cube/cubelet ices up to 1" square, or Follett
compressed nugget ice. Crushed, flake, bagged, nugget or congealed ice cannot be used. Use of
these ices can jam dispenser and void warranty. Separate any “waffle-like” sections of cubes
before adding to dispenser. If you have any questions concerning your ice type, please call
Follett’s customer service group toll free at (800) 523-9361 or (888) 2-FOLLETT or (610) 252-7301.
• Follett recommends use of an activated carbon filter for units equipped with icemakers
• Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.
Alternate electrical - 230V, 50Hz, 1 phase
Separate circuit and disconnects required for each icemaker
and dispenser. Max. fuse size 15 amps per circuit
Manual load models
U150N – dispenser 1.7 amps
U150 – dispenser 1.7 amps
U150B – dispenser 2.2 amps
Models with R4A/W Icemaker
U150R4A/W, U150NR4A/W – 7.7 amps
U150BR4A/W – 8.2 amps
U150R8A/W, U150NR8A/W – 13.7 amps
U150BR8A/W – 14.2 amps
Models with R5A/W Icemaker
U150R5A/W, U150NR5A/W – Icemaker 6.0 amps,
dispenser 1.7 amps
U150BR5A/W – Icemaker 6.0 amps, dispenser 2.2 amps
U150R10A/W, U150NR10A/W – (2) icemakers 6.0 amps
each, dispenser 1.7 amps
U150B10A/W – (2) icemakers 6.0 amps each, dispenser 2.2
amps
2

Plumbing
Dispenser – all models
3/4" female PVC slip joint dispenser drain
3/4" male slip joint to 3/4" MPT PVC adapter provided
Note: Drains to be hard piped and insulated, with1/4" per foot (6mm per 30.4cm) min. slope.
Icemaker – automatic load models only
1/4" FPT water in
1/2" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)
Note: Water disconnect within 10 feet (3m) of icemaker(s) is suggested for automatic load units.
Beverage connections - Models with beverage valves only
1/4" syrup and 3/8" carbonated water pigtails.
How the dispenser works
Follett’s U150 series ice dispensers are available in manual load configurations (using ice from another source)
or automatic load configurations, fed from one or two Follett 400 lb (181kg)/day remote icemakers.
In all models, ice is stored below the counter in the dispenser storage area. When the dispense lever or button is
pushed, the dispense motor is activated. This causes the wheel assembly in the storage area to turn, moving ice
to the vertical auger assembly, which carries ice up to the dispense chute where it drops by gravity into the
container.
In automatic load models, ice is manufactured in either one or two Follett remote icemakers. These icemakers
may be located up to 20 feet (3m) away from the dispenser. As water freezes to the inside walls of the icemaker
evaporator, a rotating stainless steel auger removes ice and carries it to the top of the evaporator assembly
where it is compressed and extruded through an outlet port. The extruded ice is then pushed through the tube to
the storage compartment of the dispenser. A level fill circuit maximizes fill in the storage area by rotating the
wheel at intervals until the bin is completely filled. When the bin is filled, a bin stat shuts the icemaker off to avoid
overfilling of the bin. U150 dispensers equipped with R4A/W (R12 refrigerant) icemakers have a safety
thermostat that prevents the icemaker from restarting for 15 to 30 minutes after the bin stat has shut the icemaker
down. In U150 dispensers with R5A/W (R22 refrigerant) icemakers, the icemaker will restart after 15 to 20
minutes if the bin is calling for ice.
From Serial Number 40600 and up, models with integral ice-waterbath beverage cooling are equipped with a
waterbath timer circuit that activates the waterbath pump 1 minute on and 10 minutes off to ensure optimal
beverage cooling.
To start-up and operate dispenser
1. Follow cleaning instructions in U150 Series Installation Manual before operating dispenser.
2. Follow start-up instructions in U150 Series Installation Manual for beverage line hook-up instructions, initial
loading of ice-waterbath beverage cooling system, manual loading restrictions and/or automatic load start-up
requirements.
3. Turn power and feed switches located inside beverage rail or ice tower to ON position.
4. For manual load models, remove front drain pan or rear lid and fill storage area with compatible ice.
5. For automatic fill models, turn icemaker (bin signal) switch(es) located inside beverage rail or ice tower to ON
position and begin to make ice.
6. When dispenser has at least 6" (153mm) of ice in storage area, press PUSH FOR ICE lever or button to
insure that dispenser is operating properly.
3

Periodic cleaning of dispenser
Caution: Do NOT run plastic parts (drain pan, dispense chute cover, dispense wheel) through a
dishwasher.
Solution A: Prepare a cleaning solution (200 ppm of available chlorine content) of Ecolab Mikro-chlor Cleaner or
equal chlorinated detergent. Solution temperature must be 75˚ to 125˚F (24˚ to 52˚C).
Solution B: Prepare a sanitizing solution (50 ppm of available chlorine content) of Ecolab Mikro-chlor Cleaner or
equal chlorinated detergent. Solution temperature must be 75˚ to 125˚F (24˚ to 52˚C).
Recommended daily cleaning of drain pan
1. Remove all debris from drain pan.
2. Pour 1 gallon (4L) hot water into drain pan to keep drain lines clear.
Recommended weekly cleaning
1. Remove drain pan and grille and wash with Solution A above. Rinse thoroughly.
2. On units with beverage valves, remove nozzles and diffusers from valves, soak for at least 10 minutes in
cleaning Solution A, rinse, sanitize with Solution B and reinstall.
3. Pour a solution of one cup (8oz/237ml) household bleach mixed with one gallon (3.8L) hot water into drain
pan to help prevent algae growth in drain lines.
Recommended quarterly cleaning (every 3 months)
Caution: Remove dispense switch from dispense chute before cleaning chute.
1. Turn power switch to OFF position.
2. Remove ice from storage area.
3. Remove dispense chute, chute cover, auger tube and auger (page 10).
4. Remove drain pan, grille, dispense wheel and waterbath cover plate (page 11).
5. Clean all components and bin storage area with Solution A, rinse thoroughly with clear water and sanitize
with Solution B.
6. On units with beverage valves, remove nozzles and diffusers from valves, soak for at least 10 minutes in
cleaning Solution A, rinse, sanitize with Solution B and reinstall.
7. For units without integral beverage cooling, clean area below wheel and stainless cover plate with Solution A,
rinse and sanitize with Solution B.
8. For models with integral ice-waterbath beverage cooling only:
• Lower drain tube found on utility connection side of dispenser and drain ice-waterbath
• Use a bottle brush to clean coils with Solution A, rinse and sanitize with Solution B
• Reposition waterbath drain line in UP position
• Pour 3.5 gallons (13L) Solution A into waterbath
• Turn power ON and tape dispense lever or dispense button back in “Dispense” position
• Allow pump to run for 2 minutes to clean pump and pump lines
• Turn power OFF and remove tape
• Drain bath and replace drain tube in UP position to avoid siphoning waterbath water
Putting unit back in service after quarterly cleaning
1. On units with integral beverage cooling, fill ice-waterbath with 3.5 gallons (13L) potable water.
2. Reassemble components.
3. For manual load units, fill unit with an approved ice (page 2).
4. For automatic load units with R4A/W (R12 refrigerant) icemakers, turn icemaker switch(es) and dispenser
power switch to ON position and allow storage area to fill.
5. For automatic load units with R5A/W (R22 refrigerant) icemakers, turn bin signal switch(es) and dispenser
power switch to ON position and allow storage area to fill.
6. Push dispense button or lever to test that dispenser is functioning properly.
Quarterly cleaning of icemaker system
Units equipped with icemakers require cleaning of icemaker system at least every three months, and
more often if local water conditions dictate. Failure to clean icemaker system will result in decreased
performance and potential damage to icemaker. Refer to Icemaker Operation and Service Manual.
4

All manual load models before serial #40600
POWER
SWITCH
POWER SUPPLY
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
YELLOW
BROWN
WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
FEED
SWITCH
YELLOW WHITE
WHEEL
MOTOR
WATERBATH
T-STAT
PURPLE M
WATERBATH
PUMP
BLACK
M
UNITS WITH BEVERAGE COOLING ONLY
RED BLUE
BLACK
5
Automatic load models with R4A/W (R12) icemaker(s), no beverage cooling –
Before serial #40600
POWER SUPPLY
POWER
SWITCH
TO ICEMAKER #1
T-STAT
LEVEL FILL
TIMER
18 MIN OFF
5 SEC ON
1
2
3
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
4
71
9
6
3
PURPLE
ICE SUPPLY
SWITCH #1
BLACK #6
ICE SUPPLY
SWITCH #2
TO ICEMAKER #2
RED #2 RED #2
RED #2 RED #1
BLACK #10
BLACK #8
WHITE
WHITE #4
FEED
SWITCH
ORANGE
YELLOW #7 YELLOW
RED
WHITE
YELLOW
BLUE
WHEEL
MOTOR
BROWN WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
DUAL FEED RELAY
(OPTIONAL)

Wiring Diagram – Automatic load models with R5A/W (R22 refrigerant) icemaker (s), no
beverage cooling – Before serial # 40600
POWER SUPPLY
POWER
SWITCH
TO ICEMAKER #1
BIN LEVEL CONTROL
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
TO ICEMAKER #2
BIN LEVEL CONTROL
WHITE
WHITE #4
FEED
SWITCH
ORANGE
YELLOW
RED
WHITE
BLUE
WHEEL
MOTOR
BROWN WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
T-STAT
LEVEL FILL
TIMER
18 MIN OFF
5 SEC ON
1
2
3
4
71
9
6
3
PURPLE
ICE SUPPLY
SWITCH #1
BLACK #6
ICE SUPPLY
SWITCH #2
RED #2 RED #2
RED #2 RED #1
BLACK #10
BLACK #8
YELLOW #7
YELLOW
6

POWER SUPPLY
POWER
SWITCH
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
BROWN WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
TO ICEMAKER #1
T-STAT
LEVEL FILL
TIMER
18 MIN OFF
5 SEC ON
1
2
3
4
71
9
6
3
ICE SUPPLY
SWITCH #1
BLACK #6
ICE SUPPLY
SWITCH #2
TO ICEMAKER #2
RED #2 RED #2
RED #2 RED #1
BLACK #10
BLACK #8
WHITE
WHITE #4
FEED
SWITCH
ORANGE
YELLOW #7 YELLOW
RED
WHITE
YELLOW
BLUE
WHEEL
MOTOR
DUAL FEED RELAY
(OPTIONAL)
PUMP
BATH
T-STAT
PURPLE
PURPLE WHITE
M
BLACK
7
Automatic load models with R4A/W (R12) icemaker(s), with beverage cooling –
Before serial #40600

POWER SUPPLY
POWER
SWITCH
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
BROWN WHITE
24V TRANSPORMER
KEY SWITCH
(OPTION)
BLACK
WHITE
24V TO
BEVERAGE
VALVES
TO ICEMAKER #1
BIN LEVEL CONTROL
T-STAT
LEVEL FILL
TIMER
18 MIN OFF
5 SEC ON
1
2
3
4
71
9
6
3
ICE SUPPLY
SWITCH #1
BLACK #6
ICE SUPPLY
SWITCH #2
TO ICEMAKER #2
BIN LEVEL CONTROL
RED #2 RED #2
RED #2 RED #1
BLACK #10
BLACK #8
WHITE
WHITE #4
FEED
SWITCH
ORANGE
YELLOW #7 YELLOW
RED
WHITE
YELLOW
BLUE
WHEEL
MOTOR
PUMP
BATH
T-STAT
PURPLE
PURPLE WHITE
M
BLACK
8
Automatic load models with R5A/W (R22) icemaker(s) and beverage cooling –
Before serial #40600

9
All Models – serial #40600 and up
POWER SUPPLY
POWER
SWITCH
M
DRAIN PAN
SWITCH
LID
SWITCH
DISPENSE
SWITCH
BLACK BLACK BLACK YELLOW YELLOW WHITE
AUGER
MOTOR
TO ICEMAKER #1
BIN LEVEL CONTROL
ICEMAKER #1
SWITCH
TO ICEMAKER #2
BIN LEVEL CONTROL
RED #1
FEED SWITCH
YEL
RED
WHT
BLUE
WHEEL
MOTOR
PURPLE #1
BIN LEVEL
FILL TIMER
18 MIN OFF
5 SEC
ON 1
23
BLACK #6
WHITE #4
24V
KEYLOCK SWITCH
(OPTION)
VVVVVV
SODA
VALVES
PRI
TRANSFORMER
SEC
1
23
BATH
TIMER
1 MIN ON
10 MIN OFF
WHITE
BLACK
R2
BLACK WHITE
BATH
RELAY
BLACK
RED
BLUE
R1
YELL #7 MBLK
R1
BLACK #14
BIN LEVEL
T-STAT
RED
ICEMAKER #2
SWITCH
RED #2
R1
BLACK #8
LEVEL FILL RELAY
R2
WHITE #9
PURPLE YELLOW
BLACK #1 PURPLE WHITE
M
BATH MOTOR
VV
PURPLE
BROWN BLACK WHITE
WHITE
BLACK
R2
RED
ORANGE
Legend
Beverage cooling option
Autofill option

Instructions for disassembly required for periodic cleaning
Dispense chute cover removal
1. Remove ice tower cover.
2. Push in on both sides of black plastic chute cover
to clear upper and lower pins.
3. After clearing pins, pull chute cover forward to
remove.
Dispense chute assembly removal
1. Remove chute cover (see instructions at left).
2. Remove thumbnut holding dispense chute
assembly and pull assembly forward.
3. Disconnect electrical connector and pull dispense
chute assembly free of tower.
Auger motor and bracket removal
1. Remove dispense chute cover and dispense
assembly (see above).
2. Remove two rear thumbnuts on motor bracket.
3. Lift motor bracket up and unplug electric quick
disconnects.
4. Remove motor and bracket assembly.
Auger and auger tube removal
1. Remove auger motor and bracket assembly (see
instructions at left).
2. Pull auger upward to clear auger tube.
3. Remove auger tube bearing plate located on
bottom of auger tube.
4. Lift auger tube upward to clear dispenser top.
10
Ce manuel convient aux modèles suivants
26
Table des matières
Autres manuels Follett Distributeur

Follett
Follett Chewblet 7 Series Guide de configuration

Follett
Follett Symphony Plus 110CT425A Guide de configuration

Follett
Follett C25R5A/W Mode d’emploi

Follett
Follett Symphony Plus 12 Series Manuel utilisateur

Follett
Follett Symphony Plus 110FB425A Manuel d'utilisation

Follett
Follett CVU155N Series Guide de configuration

Follett
Follett 15 Series Guide de configuration

Follett
Follett Symphony Plus E25CI425A Guide de configuration

Follett
Follett Symphony 12CI400A Guide de configuration

Follett
Follett Symphony Plus 110 Series Manuel utilisateur