FingerTec H2i Manuel utilisateur

Simple Fingerprint Door Access &
Time Attendance System
User Guide
H2i
support@fingertec.com
H2i

3-4 CHAPTER 1 • GETTING STARTED
Viewing the User Guide in the Internet
Included Accessories
Included Printed Materials
Activating H2i
Registering H2i
57 CHAPTER 2 • BASICS
Introduction to H2i
H2i Overview
Security Features
Restarting and Resetting H2i
818 CHAPTER 3 • CONNECTION SYNCING
Installation
Mount on Well
Communication
Description of Available Connections
Ingress Online Activation
Installation and Setup of Ingress
Connecting Terminals to Ingress
Using USB to Download/Upload Data
Communication Key
1822 CHAPTER 4 • MANAGING USER
Enrolling Administrator Card
Registration of Administrator Card
Enrolling User Cards
Verifying Card for Attendance or Access
Deleting Card User or Fingerprint User
Operations with USB Numeric Keyboard
Using the UBS Numeric Keybord
Enrolling Users
Deleting Users
Configuring IP address, Subnet Mask and Gateway by using USB numeric keypad
Restoring The Terminal to Default Factory Setting
CONTENTS

3
CONTENTS
H2i terminal
RFID Card (5 pieces)
*for H2i RFID
Screwdriver
USB Extension A Packet of Bolts
MIFARE Card (1 pieces)
*for H2i MIFARE
Door Accessories
Cable RS485 Wiegand
Output Cable
Power Supply Cable
H2i
support@fingertec.com
Num
Lock
Home
PgUp
PgDn
Del
Enter
Ins
End
Back
space
7
/
-
+
4
1
0
8
5
2
9
6
3
.
Diod
Back Plate
(Thick)
Back Plate
(Thin)
Rubber
Padding Keypad
1 • GETTING STARTED
Viewing the User Guide in the Internet
The User Guide is available in the package when you purchase FingerTec H2i. The
user guide is also published online at fingertec.com and user.fingertec.com. Choose
the language you prefer to view the User Guide.
Included Accessories

4CONTENTS
Included Printed Materials
• FingerTec Comprehensive DVD
• Quick Start Guide
• Pamphlet
• User Enrollment Template Form
• Warranty Card
Activating H2i
Connect all the cables correctly at their specific points and turn on the power sup-
ply. The H2i terminal does not have an on/off button.
Registering H2i
Make sure that you register your H2i’s warranty with us at www.fingertec.com/
ver2/english/e_main.html#

5
CONTENTS
LED
Card
Induction
Area
USB Port &
Reset button
H2i
support@fingertec.com
Reset
Fingerprint
Scanner
Speaker
Front of Terminal Bottom of Terminal
2 • BASICS
Introduction to H2i
FingerTec H2i is a simple master terminal, functioning as a time attendance and
door access device and it can be used as a time attendance recorder as well. The H2i
has a simple and sleek design as it comes without a keypad or any form of a display
screen. It communicates with its users mainly through its voice commands, as well
as its dual color LED light. To perform administrative functions on the terminal, an
administrator card is needed. However, the H2i also has the option of using a nu-
meric USB keypad as an administrative tool. As usual, more advanced management
of FingerTec H2i can be done via the included software in the package.
H2i Overview
Item Function
LED Indicating status of terminal and result of verification
Green – Terminal is in standby mode, or verify users successfully.
Red – Terminal has failed to verify user.
Fingerprint sensor To scan finger for confirmation of identity.
Card induction area Area that reads cards.
Speaker For terminal voice emission.
Reset button To restart the terminal as and when required.
USB port To connect a USB extension for data download into a USB flash
disk (pen drive). To connect a USB Keypad to input numerical
commands into the terminal (optional).

6CONTENTS
Reset
Num
Lock
Home
PgUp
PgDn
Del
Enter
Ins
End
Back
space
7
/
-
+
4
1
0
8
5
2
9
6
3
.
Keypad
Bottom of Terminal
Connect the external USB keypad to the bottom (USB port) of the H2i to insert a
specific user ID number during enrollment or deletion. You can also use the key-
pad to input commands to reset settings of the H2i back to its default factory set-
tings. Refer to page 19 for details.
The external USB keypad is an optional item, and is included in the package.
Security Features
Security features help protect the information in the H2i from being accessed by
unauthorized individual(s).
ADMINISTRATOR CARD
Registration of an administrator card to the system is important to control access
into H2i. After registration of the administration card is done, nobody can do en-
rollment, deletion or resetting on the H2i without the administration card.
TAMPER SWITCH
H2i comes with a tamper switch located at the rear of the terminal. During instal-
lation, the tamper switch is compressed against a wall. Any attempt to dismantle
the H2i will trigger an alarm
Restarting and Resetting H2i
If something isn’t working right, try to restart or reset the terminal.
RESTARTING H2i
Use a thin probe to push the reset button hidden at the bottom of the termi-
nal. The terminal will restart by itself and all the memory is retained during this
operation.

7
CONTENTS
RESETTING TO DEFAULT FACTORY SETTINGS WITH AN
ADMINISTRATOR CARD
To reset the H2i back to its default factory settings, you must first have the admin-
istrator card with you.
Green LED light blinks > Wave Administrator card 5 times at the induction area >
“Restore to default settings. Please wave your administrator card to confirm” >
Wave the administrator card to induction area to confirm > “The operation is
successful”. The system will return to verification mode.
Remarks: All settings of the H2i will be reset to the default settings. The IP address will be reset to
192.168.1.1, and the terminal ID will be reset to 1 after the process. The administrator card information
will be deleted from the memory and you will need to reenroll it. However, user information and trans-
action logs will still remain in the memory.
RESETTING TO DEFAULT FACTORY SETTINGS WITHOUT AN
ADMINISTRATOR CARD
Green LED light blinks > Detach the terminal from the wall > Release tamper switch
> This might trigger a connected alarm > Wait 30 sec > press and release the tamper
switch 3 times > The terminal will emit 3 beep sounds > the terminal will then reset
to its default factory settings
Remarks: All contents of the terminal will be deleted including the administrator card, user informa-
tion and transaction logs. All settings will return to the default settings. The IP address will return to
192.168.1.1, and terminal ID will return to 1 after the process.

8CONTENTS
Back Plate
4 feet / 1.2 meter
(recommended)
H2i
support@fingertec.com
3 • CONNECTION – SYNCING TERMINALS
Installations
FingerTec terminals offer several connections for power and communications. In-
stallations of FingerTec time attendance terminals are simple than installation for
door access functions.
Mount On Wall
Attach the back plate on the wall securely and attach the terminal to the back plate
when mounting it on the wall.

9
CONTENTS
Back of Terminal
For NC or NO
door lock
system
GND
BUT
SEN
NO
COM
NC
ACCESS CONNECTION PORT
-
TCP/IP
DC12V
Power Supply
+12V
GND
POWER SUPPLYPORT
RS485 CONNECTION PORT
1. RS485 Single Connection
2. RS485 Network Connection
+12V
IWD1
IWD0
RLED
GLED
BEEP
GND
WIEGAND INPUT
CONNECTION PORT
3rd party
controller with
26 bits wiegand
output
WD0
WD1
WIEGAND OUTPUT
CONNECTION PORT
3rd party
controller with
26 bits wiegand
intput
TCP/IP PORT
(Ethernet Connection)
RX+
RX-
RS485 Data
Converter
485A
485B
485A
485B
485A
485B
RX+
RX-
RS485 Data
Converter
Communications
Connection points for power and communication are available on top of the termi-
nals. Refer to the following diagrams for the terminals you require.

10 CONTENTS
485-
485+
GND
BUT
SEN
NO
COM
NC
AL-
AL+
ACCESS CONNECTION PORT
Release
button
Door
sensor
+
-
2
3
A
C
EM lock
(NC)
Emergency
break glass
(NC)
Key switch
(NC)
NOTE
Please refer to AdapTec AC Installer Manual if you are using AdapTec AC.
DC12V
Power Supply
+12V
GND
POWER SUPPLY PORT
485-
485+
GND
BUT
SEN
NO
COM
NC
AL-
AL+
ACCESS CONNECTION PORT
Release
button
Door
sensor
DC12V
Power Supply
+12V
GND
POWER SUPPLY PORT
+
-
1
3
B
D
EM lock
(NO)
Emergency
break glass
(NO)
Key switch
(NO)
GND
BUT
NO1
COM1
NC1
Optional to use
with Diode
Door
lock
system
GND
BUT
NO1
COM1
NC1
Optional to use
with Diode
Door
lock
system
FOR NC NORMALLY CLOSE DOOR LOCK SYSTEM
FOR NO NORMALLY OPENDOOR LOCK SYSTEM
Autres manuels pour H2i
1
Table des matières
Autres manuels FingerTec Verrouillage