Patent Pending
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com
4of 8
© 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98386. V2 11/17
HP-2 Wall Wash Arm Mount Installation Instructions
CAUTION: All power connections to be installed to local/national codes by a Certified Electrician.
Step 3 - Hang Luminaire and Wire Connections
A. Make electrical connections and push completed wiring into junction box. Install luminaire
onto wall by disengaging the bottom hook from the wall bracket. B. Rotate the arm assembly
perpendicular to the wall. C. Hook the arm bracket onto the wall bracket and engage the top
hook of the arm bracket.
Install #1/4-20 x 5/8" adjustment screws (provided) onto the arm brackets, engaging
the wall brackets. Use screws to level luminaire. Tighten to raise and loosen to lower.
Slide wall bracket cover along arm towards the wall until mounting magnets engage the
wall bracket cover to hold it in place. Turn power on to luminaire.
Let luminaire hang on the wall for wiring by hooking the arm bracket to engage bottom
hook onto the wall bracket.
A. Hang Luminaire Side View C. Secure Luminaire Perspective View
Arm Bracket
Bottom
Hook
Wall Bracket
Wall
#1/4-20 x 5/8"
Adjustment Screws
(provided)
Mounting
Magnets
B.
Top Hook
C. Top Hook
Wall Bracket
Cover
Wall Bracket Cover
Wall
Bracket
Electrical
Connections
A.
Arm Bracket,
Top Hook
B. Connect Wires Side View
#1/4-20 x 5/8"
Adjustment Screws
(provided)