Supplied By www.heating spares.co Tel. 0161 620 6677
EnglishDeutsch ItalianoFrançaisEspañol
PortuguêsNederlands
DanskTürkçe
2
GN2N
Dear Customer,
Thank you for having chosen the GN2 N, an advanced-concept Ferroli boiler
featuringcutting-edgetechnology,highreliabilityandconstructionalquality. Carefully
read this manual and keep it for future reference.
The GN2 N is a high-efficiency heat generator for the production of hot water for
heating purposes, suitable for operation with jet burners on gas or liquid fuel.
The boiler body consists of cast-iron elements, the shape of which, together with
the careful design of the fins, ensure high heat exchange efficiency in all operating
conditions.
Important warnings
• Thismanualprovides importantindications onthe safety
of operation, installation and maintenance, and is an
integral and essential part of the product. Read this
manual before installation and operation. It should be
carefully kept for future reference.
• This appliance must only be used for the purposes it
has been specifically designed for. This appliance is
used to heat water to below-boiling temperatures at
atmospheric pressure, and must be connected to a
heating and/or domestic hot water distribution system,
accordingtoits characteristics,performanceand heating
capacity. All other uses are considered improper and
thus dangerous.
• The appliance may not be opened nor its components
tampered with, except for the parts included in the
maintenance operations. The appliance may not be
modified to alter its performance or use.
• The installation and maintenance operations must be
performed according to the standards in force, the
instructions of the manufacturer and must be carried
out by professionally qualified personnel.
• Incorrect installation or poor maintenance may cause
damageto people, animalsor things.The manufacturer
declines all liability for damage deriving from errors in
the installation and operation of the appliance, and in
any case from the failure to observe the instructions
provided.
• Before performing any cleaning or maintenance
operations, disconnect the appliance from the mains
power supply using the system switch and/or the
corresponding on-off devices.
• In the event of faults and/or poor operation of the
appliance, it should be deactivated. Do not attempt to
repair the appliance. Contact professionally qualified
personnel only.
• After having removed the packaging, check that the
contents are intact. The parts of the packaging must
not be left within the reach of children, as they are
potential sources of danger.
ENGLISH
C95.02G 05
CE-0085AQ0771
0085
1QGDX05B
028693 3301698
EN303 - Appr.No.
PIN
Type
N°
GN2 N 05
0000000000
MAX. MIN.
116 80
105 73
kW
kW
Q (Hi)-INPUT
P -OUTPUT
PMS 4 bar - Tmax 110 °C- -H2O 49 I
230 V - ~50 Hz
IPX0D
Electrical power
supply
Max operating pressure
temperature
Manufacturer
Ferroli Spa
Via Ritonda 78A 37047 San Bonifacio (VR) - Italia
PIN
Trade name
Serial number
Max operating
pressure
Heat output
Uselful heat output
Bar code
Water content
Certification
The CE Mark attests that Ferroli appliances
conform to the requirements specified in the
applicable European directives.
In particular, this appliance conforms to the
following EEC directives:
• Gas directive 90/396
• Efficiency directive 92/42
• Low voltage directive 73/23 (amended by 93/
68)
• Electromagnetic compatibility directive 89/336