Expert EX9132C-RS485 Manuel utilisateur

Operation Manual of EX9132C-RS485
Serial to TCP/IP Converter
Version 1.0.1
21.09.2015

EX9132C-RS485
Manual
Page 2 EX9132C-RS485 • Manual Version 1.1 • 21.09.2015 www.expertdaq.com
Table of Contents
1 Introduction ............................................................................................................................................... 3
1.1 Overview ............................................................................................................................................. 3
1.2 Package Checklist .............................................................................................................................. 3
1.3 Block Diagram .................................................................................................................................... 4
1.4 Product Features ................................................................................................................................ 4
1.5 Product Specifications ........................................................................................................................ 5
2 EX9132C-RS485 Description & Installation ............................................................................................... 7
2.1 Top view ............................................................................................................................................. 7
2.2 Right Side ........................................................................................................................................... 7
2.3 Power Supply(Left Side) ..................................................................................................................... 7
2.4 Ethernet LAN Port ............................................................................................................................... 8
2.5 Reset Button ....................................................................................................................................... 8
2.6 LED Indicators .................................................................................................................................... 8
2.7 Wiring Architecture .............................................................................................................................. 9
3 EX9132C-RS485 Converter Configuration .............................................................................................. 10
3.1 Initial IP Configuration ....................................................................................................................... 10
3.2 Device Management Utility of EXBrowser ......................................................................................... 10
3.3 EXBrowser “View” ............................................................................................................................. 10
3.4 EXBrowser “Modify IP” ...................................................................................................................... 11
3.5 EXBrowser “Modify MAC” ................................................................................................................. 12
3.6 Web Browser Configuration .............................................................................................................. 13
3.7 Parameter Setting Page .................................................................................................................... 15
3.8 Controller Updated ............................................................................................................................ 19
3.9 Factory Default Setting ..................................................................................................................... 19
4 Setting Verification .................................................................................................................................. 20
4.1 Hyper Terminal for TCP/IP WinSock ................................................................................................. 20
4.2 Hyper Terminal for COM Port ........................................................................................................... 22
4.3 Data Transmission ............................................................................................................................ 23
5 Appendix A FAQ ..................................................................................................................................... 24

EX9132C-RS485
Manual
www.expertdaq.com EX9132C-RS485 • Manual Version 1.1 • 21.09.2015 Page 3
1 Introduction
We provide new ways of connecting legacy serial devices to a Local Area Network (LAN) or Wide Area Network (WAN).
TCP/IP converters are designed to operate serial ports over 100M bps Ethernet networks. The data is transmitted via
TCP/IP protocol. Therefore, control is available via Ethernet, Intranet and Internet. EX9132C-RS485 converter is
packaged in a PVC material case well suited for industrial environments. It provides one serial RS422/RS485 (Auto-
Detect) port. The serial port operate in common industrial configuration.
EX9132C-RS485 converter is a low-cost, high performance design. By carefully selecting high quality with competitive
prices components in the world, the products made network connectivity possible with affordable cost for virtually all
kinds of devices.
EX9132C-RS485 is a serial device server with one serial RS422/RS485 (Auto-Detect) port and it provides one socket
connection port. This operation manual will guide you step by step to learn the various functions of the EX9132C-RS485
converter.
The following topics are covered in this chapter:
Overview
Block Diagram
Product Features
Product Specifications
1.1 Overview
EX9132C-RS485 converter is designed to make your industrial serial devices Internet ready instantly. ARM Cortex-M3
CPU of EX9132C-RS485 converters makes them the ideal choice for connecting your RS422 or RS485 serial device—such
as PLCs, meters, and sensors—to an IP-based Ethernet LAN, making it possible for your software to access serial devices
anywhere and anytime over a local LAN or the Internet.
ARM Cortex-M3 CPU Series converters ensure the compatibility of network software that uses a standard network API
(Winsock or BSD Sockets) by providing TCP Server Mode, TCP Client Mode, and UDP Mode. Model EX9132C-RS485
provides 1 socket connection for remote management. ARM Cortex-M3 CPU Series Virtual COM driver and software
that works with COM port can be set up to work over a TCP/IP network in no time. This excellent feature preserves your
software investment and let you enjoy the benefit of networking your serial devices instantly.
ARM-Cortex-M3 CPU series converter supports manual configuration via the handy web browser console and many
protocols including TCP, IP, UDP, HTTP, DHCP, ICMP, and ARP. They are the best solution to network your serial devices.
1.2 Package Checklist
ARM-Cortex-M3 CPU products are shipped with the following items:
1 unit of EX9132C-RS485 converter
1 unit of Power Adaptor/Supply(9V/12V/24VDC, 500mA): Optional
Quick Installation Guide in Documentation & Software CD
Din Rail Mounting Kit: Optional
NOTE: Please notify your sales representative if any of the above items is missing or damaged.

EX9132C-RS485
Manual
Page 4 EX9132C-RS485 • Manual Version 1.1 • 21.09.2015 www.expertdaq.com
1.3 Block Diagram
Low-cost devices usually are equipped with low speed processors and limited memories. In reality, they have neither
the capability nor practicality to manage complicated network TCP/IP protocols. The ARM Cortex™-M3 32-bit processor
has been specifically developed to provide a high-performance, low-cost platform for a broad range of applications
including microcontrollers, automotive body systems, and industrial control systems, networking by converting data
stream between network TCP/IP and popular serial port signals.
Instead of processing TCP/IP packets directly, devices need only deal with those interface signals, which greatly
simplifies the complexity of TCP/IP network in linkage. The ARM Cortex-M3 processor provides outstanding
computational performance and exceptional system response to interrupt while meeting low cost requirements
through small core footprint, industry leading code density enabling smaller memories, reducing pin count, and low
power consumption.
The central core of ARM Cortex-M3 processor, based on a 3-stage pipeline Harvard bus architecture, incorporates
advanced features including single cycle multiply and hardware divide to deliver an outstanding efficiency of 1.25
DMIPS/MHz. The ARM Cortex-M3 processor also implements the new Thumb®-2 instruction set architecture, which
combined with features such as unaligned data storage and atomic bit manipulation delivers 32-bit performance at a
cost equivalent to modern 8- and 16-bit devices.
1.4 Product Features
Data Conversion between RS422/RS485 and Ethernet
EX9132C-RS485 converter device (RS422∕RS485*1 port) data/signal into the TCP/IP package data/signal and
send them out with the Ethernet Data Stream; or convert the TCP/IP package data/signal into serial device
data/signal.
Socket Communication
EX9132C-RS485 is provided one socket connection.
Digital I/O Activating (Optional)
EX9132C-RS485 provides eight TTL of digital I/O.
Convert the sensors’ statuses (the sensors are connected to the converter) into the TCP/IP package data and

EX9132C-RS485
Manual
www.expertdaq.com EX9132C-RS485 • Manual Version 1.1 • 21.09.2015 Page 5
send them out with the Ethernet Data Stream; or use the TCP/IP package data to activate/deactivate the
specified digital outputs.
Dynamic IP Configuration
Support DHCP client mode, simplifying network address configuration and management.
Dual LAN Speed
Support 10/100 Mbps Ethernet, auto-detected.
Server / Client Dual Modes
EX9132C-RS485 converter device can be configured as network server or network client. In the client mode, it
can be installed in network which is protected by NAT router or firewall without a real IP address.
Web-based Setup
Parameters setup is based on HTTP protocol by using standard browsers (IE and Netscape). No special software
would be required.
Built-in Security Control
Security protect by login password to prevent intruders.
Remote Update
Firmware can be updated directly via Ethernet network to keep up with latest network standards.
1.5 Product Specifications
CPU: ARM Cortex™-M3 32-bit processor, 50MHz
RAM: 64K Bytes SRAM
ROM: 256K Bytes Flash ROM
Ethernet
o Port Type: RJ-45 Connector
o Speed: 10 /100 M bps (Auto Detect)
o Protocol: ARP, IP, ICMP, UDP, TCP, HTTP, DHCP, ICMP
o Mode: TCP Server∕TCP Client∕UDP Client / Virtual COM / Pairing
o Setup: HTTP Browser Setup (IE & Netscape)
o Security: Login Password
o Protection: Built-in 1.5KV Magnetic Isolation
Serial Port 1:
o Port Type: RS422/RS485(Auto-Detect)
o Connector: Terminal Block
o Speed: 300 bps-115.2K bps
o Parity: None, Odd, Even, Mark, Space

EX9132C-RS485
Manual
Page 6 EX9132C-RS485 • Manual Version 1.1 • 21.09.2015 www.expertdaq.com
o Data Bit: 5, 6, 7, 8
o Stop Bit: 1, 2
o Signals:
RS422: Rx+, Rx-, Tx+, Tx- (Surge & Over Current Protect)
RS485: Data+, Data- (Surge & Over Current Protection)
o Built-in RS422/RS485 Pull High-Low Resistor
Socket Connection: 1 Connection
15KV ESD for all signal
Watch Dog Function
Virtual Support Windows 2000 /2003 / XP / Vista / 7 / 10
Firmware On-line Updated Via Ethernet
Power: DC 9 - 24V, 500mA (5,5 mm DC Jack / optional: Terminal Block)
LED Lamp:
o RX/TX(Green)
o LINK(Red)
o SYS (Green)
Environment:
o Operating Temperature: +0°C to 70°C
o Storage Temperature: -10°C to 80°C
Dimensions: 115 * 90 * 27 mm (W * D * H)
Weight: 140 g
RoHS: Compliant with RoHS
Regulatory Approvals: FCC, CE
Warranty: 1 year

EX9132C-RS485
Manual
www.expertdaq.com EX9132C-RS485 • Manual Version 1.1 • 21.09.2015 Page 7
2 EX9132C-RS485 Description & Installation
2.1 Top view
2.2 Right Side
Serial I/O Port of RS422/RS485. Connect the serial data cable between the converter device and the serial devices.
Follow the parameter setup procedures to configure the converter (see the following chapters).
2.3 Power Supply(Left Side)
EX9132C-RS485 TCP/IP converter device is powered by a single 9/12/24VDC (inner positive/outer negative) power
supply and 500mA of current. A suitable power supply adapter is part of the packaging. Connect the power line to the
power jack at the left side of EX9132C-RS485 TCP/IP converter device and put the adapter into the socket.

EX9132C-RS485
Manual
Page 8 EX9132C-RS485 • Manual Version 1.1 • 21.09.2015 www.expertdaq.com
2.4 Ethernet LAN Port
The connector for network is the usual RJ45. Simply connect it to your network switch or Hub. When the connection is
made, the LAN LED indicator will light up. When data traffic occurs on the network, red DATA LED indicator will blink
during data transferring and receiving.
2.5 Reset Button
If by any chance, you forget the setup password, or have incorrect settings making EX9132C-RS485 converter
inoperable. First, turn on the power. Second, use any point tip to push this button and hold it about 3 seconds All the
parameters will be reset to the factory default. But do not over 5 seconds, it will enter update mode
2.6 LED Indicators
RX/TX (Green):
Port data transmitting indicator (When data are sending to the network, the LED will blink.)
LINK (Red):
Data Link indicator (When data are Link by the network, the LED will blink.)
SYS (Green):
It is a device statues indicator (When EX9132C-RS485 is operated in normal statues, the LED will blink once per
second.)

EX9132C-RS485
Manual
www.expertdaq.com EX9132C-RS485 • Manual Version 1.1 • 21.09.2015 Page 9
2.7 Wiring Architecture
RS422/RS485 Wiring Architecture
RS422 Wiring
R
S
4
8
5
W
i
r
i
n
g
EX9132C-RS485
E
X
9
1
3
2
C
-
R
S
4
8
5
Serial Device
S
e
r
i
a
l
D
e
v
i
c
e
HUB LAN Cable
T+ R+
T- R-
R+ T+
R- T-
D+ D+
D- D-
HUB LAN Cable
_____________
_____________
_____________
_____________
_____________
_____________
When you finish the steps mentioned above and the LED indicators are as shown in above diagram, the converter is
installed correctly. You can use the Setup Tool “EXBrowser.exe” to setup the IP Address.
To proceed the advanced parameter setup, please use a web browser (IE or Netscape) to continue the detailed settings.

EX9132C-RS485
Manual
Page 10 EX9132C-RS485 • Manual Version 1.1 • 21.09.2015 www.expertdaq.com
3 EX9132C-RS485 Converter Configuration
3.1 Initial IP Configuration
When sett up your converter for the first time, the first thing you should do is to configure the IP address. This chapter
introduces the method to configure the device server’s IP address. For more details about network settings, please see
the Network Settings section in Chapter 4, “Web Console Configuration”.
The following topics are covered in this chapter:
Device Management Utility of EXBrowser
EXBrowser “View”
EXBrowser “Modify IP”
EXBrowser “Modify MAC”
3.2 Device Management Utility of EXBrowser
On PC we provide a Device Management Utility named “EXBrowser.exe” which is an executable program in Windows
32-bit environments. EXBrowser setup tool is used to detect and setup the installed converters. It uses UDP broadcast
packets to query and configure converters on the network.
When you activate the tool, it will detect the existence of the installed converters and depict the converters’ status such
as IP address, Subnet Mask, MAC Address, and Device ID (see Figure 4.1). The Setup Tool only can setup one converter
at a time. Thus if there are more than one converter on the network, please shut down or disconnect other converters.
Otherwise the EXBrowser.exe can not detect the converter.
Due to the nature of broadcast UDP packets, EXBrowser has following characteristics:
Broadcast packets are not limited by subnet. Even if the IP address of the converters and the computer running
EXBrowser that do not belong to the same subnet, it still works fine.
Broadcast packets can not pass routers. EXBrowser can only be used to monitor devices with computer running
EXBrowser in the same segment of local area network.
3.3 EXBrowser “View”
View -> Refresh
There are two ways for refreshing the status of existing devices. You may select the item “View” to refresh the
status of existing devices on LAN. Another is to click the icon as red color remark as below. EXBrowser will send
another query to get updated information.
Table des matières
Autres manuels Expert Convertisseur de média

Expert
Expert EX-9132C-2 Manuel utilisateur

Expert
Expert EX-9486C-W Manuel utilisateur

Expert
Expert EX-9132C-2RS485 Manuel utilisateur

Expert
Expert EX9132C-2-MTCP Manuel utilisateur

Expert
Expert EX-9543 Manuel utilisateur

Expert
Expert EX952N Series Guide d'installation

Expert
Expert EX-9486C-W Manuel utilisateur