Exodraft ESP-10 Manuel utilisateur

Your energy. Optimized.
Electrostatic Particle Filter
ESP-10
UK |Read and save these instructions!


Your energy. Optimized.
Product description 7
Scope of supply 7
Accessories and spare parts 7
Functionality of the electrostatic precipitator 8
Automatic on/off 9
Self-cleaning function 9
Technical specications 10
Precautions and user instructions 13
Mechanical installation 14
Transportation safety 14
Minimum distance 16
Before installation onto a chimney 17
Installation onto a brick chimney 18
Installation onto a steel chimney 20
Electrical Installation 22
Start-up and conguration 23
General 23
System test 23
User operation instructions 24
User operation 24
Indications on the ESP-10 lter 25
Maintenance and troubleshooting 26
Safety precautions 26
User maintenance 27
Inspection and service 28
Cleaning procedure 30
Troubleshooting 32
Other problems and solutions 33
Particle Filter | ESP-10
Content

Disposal
Electrical and electronic equipment (EEE) often contain materials, components and substances
that may harm the environment or be hazardous to your health. Products (WEEE) marked with
the ‘crossed-out wheeled bin’ symbol should be disposed of separately from other waste at
the end of its life. Though legislation may differ from country to country we strongly advise
that electrical and electronic waste is separated from other waste and disposed of according to
national legislation to protect the environment and personnel that may come into contact with
waste.
How to use this manual
This manual has been prepared based on the specific product and
contains relevant technical information and installations guides.
Accessories and spare parts are not covered by this manual.
Please refer to the individual manuals of these components.
This installation manual does not contain any system design documentation.
Failure to observe instructions marked with a danger symbol
may result in personal injury and/or damage to the product.
Errors and omissions excepted.

Symbols
The following symbols may be used in the manual
to draw attention to danger or risk of personal
injury or damage to the product.
General prohibition
Failure to observe instructions marked with the prohibited
symbol may result in extreme danger or serious personal injury.
General warning
Failure to observe instructions marked with a danger symbol
may result in personal injury and/or damage to the product.
General attention
Marks a dangerous situation that, in the worst-case scenario,
can cause serious personal injury or significant damage to the product.
Electricity hazard/High Voltage
Marks a situation in which caution is advised due to the risk of high voltage electric
shock which can cause serious personal injury or significant damage to the product.
Connect an earth terminal to the ground
Failure to observe instructions marked with a danger symbol
may result in personal injury and/or damage to the product.
Permitted and approved
Permitted and approved method of installation.
Prohibited and not approved
Prohibited and not approved method of installation.

Warning
To minimise the risk of fire, electric shock, personal injury
and/or damage to the product please observe the following:
• Please always read the manual and only use the product in accordance with the
manufacturer’s instructions. If in doubt, contact one of the Exodraft specialized dealers.
• All installations must be carried out by properly qualifi ed personnel in accordance with
national legislation and regulations.
• This product must be earthed. Get assistance from an qualifi ed electrician when in doubt.
• The chimney fan must always remain switched on when the fireplace is in use.
• Ensure that the chimney has been swept before mounting the fan to avoid chimney fire
• The product must be accessible for service and maintenance.
• Prior to servicing the product, disconnect the power supply to the lter. Turn o the main
switch located on the lter. Ensure that the heat source and the lter cannot be turned on acci-
dentally. Let the lter cool down before service or cleaning.
• Automatic power on/off function; when the temperature in the chimney increases, high
voltage automatically switches on. Touching the electrode or the electrode holder may be
fatal.
• Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is
installed.
• If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please
ensure that the design meets the requirements of BS EN15287-1. If this cannot be achie-
ved, a smoke alarm must be installed in the same room as the heat appliance.
• Undesirable stoking practice may result in problems, such as excessive soot accumulation,
chimney fi res, etc., which may damage the product.
UK
Your energy. Optimized.

UK |7
3112023_ESP-10_UK
Warning
To minimise the risk of fire, electric shock, personal injury
and/or damage to the product please observe the following:
• Please always read the manual and only use the product in accordance with the
manufacturer’s instructions. If in doubt, contact one of the Exodraft specialized dealers.
• All installations must be carried out by properly qualifi ed personnel in accordance with
national legislation and regulations.
• This product must be earthed. Get assistance from an qualifi ed electrician when in doubt.
• The chimney fan must always remain switched on when the fireplace is in use.
• Ensure that the chimney has been swept before mounting the fan to avoid chimney fire
• The product must be accessible for service and maintenance.
• Prior to servicing the product, disconnect the power supply to the lter. Turn o the main
switch located on the lter. Ensure that the heat source and the lter cannot be turned on acci-
dentally. Let the lter cool down before service or cleaning.
• Automatic power on/off function; when the temperature in the chimney increases, high
voltage automatically switches on. Touching the electrode or the electrode holder may be
fatal.
• Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is
installed.
• If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please
ensure that the design meets the requirements of BS EN15287-1. If this cannot be achie-
ved, a smoke alarm must be installed in the same room as the heat appliance.
• Undesirable stoking practice may result in problems, such as excessive soot accumulation,
chimney fi res, etc., which may damage the product.
UK
Your energy. Optimized.
Product description
An Exodraft ESP-10 particle lter is designed as an electrostatic precipitator with a built-in chimney fan
for mounting on top of the chimney. The lter is equipped with a self-cleaning function (patented) and
designed to reduce the emissions from wood-burning appliances as well as facilitate easier lighting and
refueling.
The ESP-10 comes with an integrated isolation switch and a 5-metre cable with open wires for plug
installation.
The lter is designed for closed wood-burning replaces (stoves) with a nominal heat output of maximum
10 kW.
Incorrect ring may result in problems with soot, chimney res, etc. which might damage the product.
Please check out this site for advice about lighting and maintaining a re:
www.exodraft.com
Scope of supply
• ESP-10 with 5-metre connection cable (with open wires)
• Installation manual and user instructions
• Labels for chimney sweep, indicating that power to the lter must be cut off
before cleaning the chimney to be placed at replace and cleaning locations.
A mounting adapter for mounting the Exodraft ESP-10 on the chimney must be ordered separately to t the
existing chimney system.
Accessories and spare parts
The table below shows the accessories and spare parts available for the RS-models.
Accessories* Spare parts
Adapters (for steel and brick chimneys) Fan motor
Flanges (for brick chimneys) Cleaning motor
Electrode
Insulator
Controller
*This manual does not describe the specic use of accessories. We refer to the separate manuals for such components.
For more details contact your Exodraft dealer.

8|UK
Your energy. Optimized.
Functionality of the electrostatic precipitator
The Exodraft lter is an electrostatic precipitator. The lter reduces the number of ne and ultrane par-
ticles in a ue gas ow by creating an electrostatic eld between the charging electrode and the collection
electrode.
The electrostataic eld in the ESP-10 is generated by a charging electrode connected to a high voltage
generator which ionizes the gas in its surroundings and as a result charges the particles and delivers an
electrostatic eld strong enough to push the charged particles towards a collection electrode.
While the electrostataic eld is on, the precipitated particles will remain attached to the collection elec-
trode. When the temperature and oxygen inside the lter is on a certain level, most of the attached particles
will self-ignite and burn off in a complete combustion as a part of the normal operation.
The lter’s self-cleaning functionality will remove the remaining particles inside the lter.
Insulator
Electrode
Self-cleaning
particle grid
Smoke inlet
Smoke outlet
Temperature sensor

UK |9
3112023_ESP-10_UK
Automatic on/off
The Exodraft ESP-10 lter has a built-in temperature sensor that makes it possible to control the start and
stop function automatically.
After the replace is lit, the ESP-10 lter will activate as soon as the temperature sensor records an
increase in temperature. Depending on the chimney application, the start delay will be 10-30 seconds.
When no fuel is added to the wood stove, the chimney temperature will start to decrease. Once the tempe-
rature drops below 40 °C, the ESP-10 lter continues to operate for 30 minutes, after which sleep mode is
engaged.
ATTENTION! When the replace and chimney are cold, it may, depending on relevant factors
(stove model, chimney size, fuel type etc.), be necessary to turn the Exodraft ESP-10 lter off
and then back on at the power supply to get the full benet of the ventilators mechanical draft.
Self-cleaning function
The Exodraft ESP-10 lter is equipped with an automatic cleaning function that periodically cleans the lter
during operation. The user may be able to hear the lter cleaning in some situations as the self-cleaning
procedure is a mechanical movement inside the lter.
If the lter is restarted and the replace is cold, the automatic cleaning process will run for 3-5 seconds.
When the replace is in use the cleaning procedure is initiated after 5 hours, only starting when the re-
place is being refueld.

10 |UK
Your energy. Optimized.
Warranty
All Exodraft products are covered by a 2-year guarantee as per European consumer rights legislation. For
some countries an extended period of guarantee may apply depending on either national legislation or
other clearly stipulated conditions. Customer complaints must be handled by a specialised dealer or
wholesaler (preferably where the Exodraft product has been bought originally). An updated list of Exodraft
specialised dealers can be found on our website for the country in question.
Exodraft products must always be installed by properly qualied personnel. Exodraft reserves the right to
change these guidelines without prior notice.
The warranty and liability does not cover instances regarding personal injury or damage to property or the
product that can be ascribed to one or more of the following causes:
• Failure to follow this installation and operation manual
• Incorrect installation, start-up, maintenance or servicing
• Improper repairs
• Unauthorised structural modications made to the product
• Installation of additional components that have not been tested/approved with the product
• Any damage resulting from continued use of the product despite an evident defect
• Failure to use original spareparts and accessories
• Failure to use the product as intended
• Exceeding or failure to meet the limit values in the technical data
• Force majeure
Technical specications
The RS fan is designed for vertical discharge. It is available in to colors.
The body and casing are manufactured in stainless steel and equipped with a aluminum vane.
Particle lter Vane
ESP-10-STEEL
ESP-10-BLACK Aluminium vane
All models can be opened for service and cleaning purposes.
The ESP-10 vane has been developed to solve draught problems by creating a mechanical draught on
chimney, while the electrostatic precipitator lter reduces the number of ne and ultrane particles in a ue
gas ow.
The ESP-10 lter has been designed for closed wood-burning replaces and stoves with a nominal heat
output of maximum 10 kW.. The lter rst reaches its full efciency after 10-20 res or burning of approx.
15-20 kg of rewood.
The ESP-10 lter can tolerate ue gas temperatures up to 400°C.
Autres manuels pour ESP-10
1
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Exodraft Système de filtration d'eau
Manuels Système de filtration d'eau populaires d'autres marques

Wisy
Wisy LineAir 100 Manuel utilisateur

Schaffner
Schaffner Ecosine FN3446 Series Manuel d'utilisation

Pentair
Pentair FLECK 4600 SXT Guide de l'utilisateur

H2O International
H2O International H20-500 Manuel utilisateur

Renkforce
Renkforce 2306241 Manuel utilisateur

Neo-Pure
Neo-Pure TL3-A502 Manuel utilisateur