5 of 42
2 Periodic maintenance
In order to ensure the highest-possible availability and to avoid subsequent damage caused by insucient lubricati-
on, periodic maintenance must be carried out in the device according to the following instructions.
The maintenance intervals are orientated according to the degree of usage (see maintenance requirements table
2.2) and the number of strapping cycles carried out. However, we recommend performing a service at least every
two years.
In addition, the details in the operating instructions (section 6.1) apply with regard to smaller maintenance work by
the customer.
2.1 Implementation
2.1.1 Cleaning
● Cleaning the tensioning and sealing area from abrasion and metal chips. This can be done with compres-
sed air assistance. Attention! It is essential to wear protective goggles with a good seal. Metal splinters
can be flung away by compressed air.
● Removal of excess contamination on other components of the device.
2.1.2 Visual check
● Is there any visible damage to the housing, base plates and other components that is relevant for its func-
tioning?
● Are all screws and other components that could be removed present and tight, and are they the original
part?
● Does the strap width setting match with the strap in use?
● Are all original wear parts with correct article number installed?
Refer to operating instructions (chapters 6.4, 6.5 and 6.6).
2.1.3 Function test
– Inserting the rechargeable battery: The backlight should illuminate briey
– Check the user interface function: Are all buttons functional? Select MAN Mode
– Operate the trigger: Testing the function of the strap insertion aid (on / o)
– Pull up the trigger and hold it. Press the tensioning
and sealing buttons one after the other:
With the lever pulled up, only one beeping tone sounds
per each button?
– Set the tool to „Manual“ operating mode. Prepare
the strapping, insert and tension the strap:
Is the strap tension range matching the strap size
(Plausibility check)?
– Actuate sealing button: Listen for noises. Is the seal correctly grasped? Is the
strap being cut? Does the backlight go green, is the
tool ready again?
– Remove the tool from the packaged goods: The end of the strap should remain in the tool. Can the
tool be easily removed from the seal?
– Check the seal: refer to operating manual, chapter 5.2
2.1.4 Maintenance
● If an error has occurred during the function test, rst continue with rectication according to chapter 3.
● Carrying out maintenance according to chapters 2.2, 2.3, 2.4 and 2.5.
2.1.5 Read out the cycle counter
►Touch the operating panel, the backlight lights up.
►Press the blank keypad between «Favourite» and
«operating mode».
►Raise the rocker lever. Now the number of cycles (2) is
displayed at the top of the display.
Evers GmbH Graf-Zeppelin-Str. 10 46149 Oberhausen Telefon +49 208 99475-0 Telefax +49208 99475-31 evers@eversgmbh.de eversgmbh.de