Exhausting cooker hood. The equipment is constructed in
accordance with European Standards and with the requirements
included in the following Directives: 2006/95EC ( Low Voltage
Directive), 2004/108 (Electromagnetic Compatibility).
1 INSTALLATION
The equipment (Picture 1) is made of the following items:
1) Telescopic inside structure (Picture 1-1)
2) External telescopic chimney (Picture 1-2)
3) Cookerhood module (Picture 1-3
Read the instruction manual before installing and/or using the
hood .
In order that the minimum distance between the supporting
surface for the cooking pots on gas hob and low-voltage
components present in the hood is at least 65cm as required by
the regulations in force, it is necessary that the lower part of the
hood is at least 65-70cm away from the work top.
If the mounting instructions of the gas cooker indicate a wider
distance, respect it. The unit must not be mounted above cookers
tted with top radiant plate.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge
exhaust fumes produced by gas- fed equipments or fuel-fed
equipments (this does not apply to ltering hoods).
The room must be adequately ventilated when the hoods is used
together with other gas-fed or fuel-fed equipments.
The hood is equipped with all the necessary fastenings for its
installation, which are suitable for most surfaces. Anyway, ask
to a professional to verify that the installation surface is strong
enough. Installation must be carried out by qualied installers
according to present regulations.
For an easy access, it is advisable to move possible furniture
under the installation area.
Installation of the structure to the ceiling (Picture 2)
1. Adjust the height H of the telescopic structure employing the
screws as in Picture 2-A, considering that the cookerhood
Module height is mm. 350 and that minimum distance
between the equipment and the cooktop is mm. 700 as
described in Picture 1.
2. Fix to the ceiling the telescopic structure by means of the
provided screw anchors been (Picture 2-B).
Installation of the telescopic chimney (Picture 3).
3. Put in and x the upper ue chimney to the telescopic
structure by means of the screws as in Picture 3-C.
4. Put in the lower ue chimney completely upwards and hold
it up temporarily, tightening the screws as in Picture 3-D.
Installation of the cookerhood Module (Picture 3)
5. Put in the cookerhood module on the telescopic structure
and x the screws as in Picture 3-F.
6. At this stage of the operation you can take off the screws
employed in Picture 3-D to hold on the lower ue chimney
and let it go down holding on the cookerhood module.
2 ELECTRICAL CONNECTIONS
This appliance must be connected to an earthed power supply.
Two types of electrical connection can be used:
1. Using a standard plug to be connected to the power cable
and inserted in a mains socket which must be accessible (so
that the plug can be disconnected when servicing is carried
out). Make sure that the plug is accessible also after the
complete installation of the equipment.
2. By means of a xed mains connection, tting a bipolar
switch, which ensures the disconnection, with an opening
distance of the contacts allowing a complete disconnection
on the conditions of the overvoltage III category, according
to installation regulations. The ground connection (yellow-
green wire) must not be interrupted.
Refer to the plate inside the hood for the mains voltage and
frequency ratings.
3 USE
This cooker hood can be employed as exhausting or ltering.
Exhausting (Fig. 4). The carbon lters should not be installed on
the hood in exhausting version.
Kitchen smokes are driven outside through a ue joined to the
exhaust pipe ue connector.
Pipes must be communicating with the exterior of the house. The
diameter of the outlet of the hood is 150mm. A 150-125 reduction
is provided with the hood.
This pipe must not under any circumstances be connected to
cooker, boiler or burner exhaust pipes, etc.
Filtering (Fig. 5H). The fumes pass through the carbon lters
to be puried and recycled into the kitchen through a pipe
connected to the outlet of the hood up to the hole in the top of
the cabinet. This hole must be free and communicating with the
kitchen.
In the ltering version you must install the two carbon lters on
the sides of the aspirator. To install the carbon lters you must
rst remove the metal grease lters (Fig. 6) and then install
carbon lters by turning them counterclockwise (Fig. 7).
4 OPERATION
The hood is equipped with a multispeed motor.
It is recommended that low speed be selected for normal kitchen
conditions, and higher speeds only to combat a heavy build-up
odours and vapours.
ELECTRONIC CONTROLS
The controls (Fig. 7) have buttons for switching on the TL light, for
switching on the motor and selecting the T1-T2-T3-T4 operating
speed.
By pressing of the command T1 the motor starts running at
the 1st speed. The commands T2-T3-T4 switch the motor on
respectively at the 2nd, 3rd, 4th speed. In order to switch
the motor off press T1 once if set at the 1st speed, twice if set at
the 2nd, 3rd and 4th speed.
With the button T4, select the maximum speed of the extraction
fan for 5 minutes (LED blinking), after which the extraction fan
will automatically switch to the 3rd speed.
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR COOKER HOODS
MODEL X301ISL 230 Vac - 50 Hz
0-1 2 3 4
TL T1 T2 T3 T4