ETCR ETCR2000E Plus Manuel utilisateur



CONTENT
I.Attention ............................................................................................ 1
II. Brief Introduction.............................................................................. 3
III. Specification.................................................................................... 6
1. Model of Series............................................................................... 6
2. Ranges and Accuracy of Measurement......................................... 6
3. Specifications.................................................................................. 6
IV. Structure of Meter............................................................................ 9
V. Liquid Crystal Display..................................................................... 10
1. LCD Screen.................................................................................. 10
2. Description of Special Symbols.................................................... 10
3. Examples Illustrated..................................................................... 12
VI.Function Zoom Table................................................................... 14
VII. Operating Method........................................................................ 14
1. Boot up......................................................................................... 14
2.Shutdown.................................................................................... 15
3.Resistance Measurement........................................................... 16
4.Current Measurement................................................................. 17
5.Date Lock/Release/Storage........................................................ 18
6.Data Access................................................................................ 19
7.Alarm Settings............................................................................. 19
8.Access to Alarm Critical Value.................................................... 20
9.Clear Data................................................................................... 20

10.Data Upload.............................................................................. 20
VIII. Measurement Principle............................................................... 21
1. Principle of Resistance Measurement.......................................... 21
2. Principle of Current Measurement ............................................... 21
IX. Measurement Method of Earth Resistance.................................. 22
1. Multi-Point Grounding System ..................................................... 22
2. Limited Point Grounding System.................................................. 23
3. Single-Point Grounding System................................................... 25
X. Field Application............................................................................. 28
Ⅺ. Matters need attention when measuring grounding resistance... 33
Ⅻ. Bill of Loading............................................................................... 35
XIII. Parts List and Assembly Details................................................. 35
1. Parts List....................................................................................... 35
2. Assembly Details.......................................................................... 37
XIV. Trouble shooting......................................................................... 37

-1-
I.Attention
Thank you for purchasing this pincers earth tester from ETCR
Electronic Technology Company. In order to make better use of the
product, please be certain:
----To read this user manual carefully.
----To comply with the operating cautions presented in
this manual.
1 Under any circumstances, use the Meter should pay special
attention to safety.
2 Pay attention to the measurement range of the Meter and the
using environment provided.
3 Pay attention to the text labeled on the panel and back plane
of the Meter.
4 Before booting up, the trigger should be pressed for 1-2 times
to ensure the jaws are well closed.
5 At Boot time, DO NOT press the trigger, nor clamp any wire.
6 Before the auto inspection is completed and the "OL Ω" sym-
bols are showed, the measured objects cannot be clamped
on.
7 The jaw planes contact must be maintained clean, and should
not be polished with corrosive and rough materials.
8 Avoid any impact onto this Meter, especially the Jaw contact
surface.
9 This Meter will have some buzzing sound in measurement

-2-
process, and it is normal.
10 The measurement current of the wire should not exceed the
upper limit of the Meter.
11 Please take out the batteries in the case of the Meter being
idle for a long time.
12 The dismantling, calibration and maintenance the Meter shall
be operated by the authorized staff.
13 If the continuing use of it would be dangerous, the Meter
should be stopped using immediately, and immediately sealed
for the treatment by the authorized agencies.

-3-
II. Brief Introduction
ETCR2000E+/ETCR2100E+ Multifunctional Clamp Earth Resis-
tance Tester was designed by technical department of ETCR
Electronic Technology Company, it can fulfilling historical inquiry
and online real-time monitoring through monitoring software, dy-
namic display, alarm indicator, and with the functions like historical
data access, reading, preservation, report forms, printing and so
on. In addition,it can measure 40A leakage current t and more
other functions, suitable for a wide place. Its performance is mainly
reflected in:
Breakthrough in self-test the boot a long time to wait, start
immediately into the test.
Breakthrough relay self-test mode, using the most ad-
vanced processing algorithms and digital integration
technology, a fully intelligent.
Break the old product to heavy issues, more in line with
characteristics of handheld devices.
New design, panel operation with 6 buttons, better per-
formance.
An increase of sound and light alarm, "beep—beep--beep
--" alarm sound.
Increase the interference signal recognition indicator.
Improved anti-jamming capability and test stability.
Stored data: 99 Units.
Wider range: 0.01Ω-1200Ω、0.00mA-40.0A.

-4-
Lower power consumption: Maximum operating current
not exceeding 50mA.
Monitoring software has the function of online real-time
monitoring, history inquiry, dynamic display, with software
alarm Settings, display current waveform, maximum value,
minimum value and average value. In addition, the users
can read, inquire, store, analyze, process, sequence his-
torical data and generate and print a fitting curve and re-
port.
Historical data can saved as .TXT file or .DOC file.
ETCR series of Pincers Earth Tester is widely used in the groun-
ding resistance measurement of the power, telecommunications,
meteorology, oilfield, construction and the industrial and electrical
equipment.
ETCR series of Pincers Earth Tester, in the measurement of a
grounding system with loop current, does not require breaking
down the grounding wire, and need no auxiliary electrode. It is safe,
fast and simple in use.
ETCR series of Pincers Earth Tester can measure out the faults
beyond the reach of the traditional methods, and can be applied in
the occasions not in the range of the traditional methods.
ETCR series of Pincers Earth Tester can measure the integrated
value of the grounding body resistance and the grounding lead
resistance.
ETCR series of Pincers Earth Tester is equipped with a long jaw,

-5-
as indicated in the figure below. A long jaw is particularly suitable
for the occasion of grounding with the flat steel.

-6-
III. Specification
1. Model of Series
Model
Jaw Size (mm)
Note
ETCR2000E+
65mm×32mm
Long Pincers Jaw
ETCR2100E+
Φ32mm
Round Pincer Jaw
2. Ranges and Accuracy of Measurement
Mode
Range
Resolution
Accuracy
Resistance
0.010Ω-0.099Ω
0.001Ω
±(1%+0.01Ω)
0.10Ω-0.99Ω
0.01Ω
±(1%+0.01Ω)
1.0Ω-49.9Ω
0.1Ω
±(1%+0.1Ω)
50.0Ω-99.5Ω
0.5Ω
±(1.5%+0.5Ω)
100Ω-199Ω
1Ω
±(2%+1Ω)
200Ω-395Ω
5Ω
±(5%+5Ω)
400-590Ω
10Ω
±(10%+10Ω)
600Ω-880Ω
20Ω
±(20%+20Ω)
900Ω-1200Ω
30Ω
±(25%+30Ω)
Current
0.00mA -9.95mA
0.05mA
±(2.5%+2mA)
10.0mA -99.0mA
0.1mA
±(2.5%+5mA)
100mA -300mA
1mA
±(2.5%+20mA)
0.30A-2.99A
0.01A
±(2.5%+0.1A)
3.0A-9.9A
0.1A
±(2.5%+0.3A)
10.0A-19.9A
0.1 A
±(2.5%+0.5A)
20.0A-40.0A
0.1 A
±(3%+1A)
3. Specifications
Resistance Range
0.01Ω-1200Ω
Current Range
0.00mA-40.0A
Resistance Resolu-
0.001Ω
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels ETCR Équipement de test
Manuels Équipement de test populaires d'autres marques

SMART
SMART KANAAD SBT XTREME 3G Series Manuel utilisateur

Agilent Technologies
Agilent Technologies BERT Serial Manuel utilisateur

Agilent Technologies
Agilent Technologies N3280A Manuel utilisateur

Vernier
Vernier Go Direct Voltage Manuel utilisateur

Lifeloc
Lifeloc R.A.D.A.R. Manuel utilisateur

Fluke
Fluke T5-600 Instructions d'utilisation et d'installation