ERVOR G06 Mode d'emploi

Page 1
Manual G06
Edition: 10/2015 - rev A
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
AIR COMPRESSOR
OPERATING AND
MAINTENANCE MANUAL

Page 2
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
Manual G06
Edition: 10/2015 - rev A
IMPORTANT
This operating and maintenance manual is not stipulated by contract and Ervor reserves the right
to alter its compressors, accessories and corresponding documentation without notice.
No part of this manual may be reproduced without the written permission of Ervor (SCA).
- Model ......................................................................... Reference
-G06 STD ........................................................................... ref: 8 101 028
-G06 Bureau Veritas ............................................................ ref : 8 101 032
G06 Bureau Veritas (with oil level switch) ............................ ref: 8 101 075
-G06 Lloyd’s Register of Shipping (with oil level switch) ......... ref : 8 101 035
8 101 028
G06
PERSONNEL SAFETY
Whenever work is to be carried out on the compressor, the electric current must be switched
off or stop engine, and the compressed air delivery must be closed.

Page 3
Manual G06
Edition: 10/2015 - rev A
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
SUMMARY
1 - GENERAL PRESENTATION ........................................................................ 6
1 - A - WARRANTY ............................................................................................................. 7
2 - TECHNICAL CHARACTERISTICS .............................................................. 8
2 - A - TECHNICAL DESCRIPTION ................................................................................... 8
2 - B - MATERIAL DESCRIPTION ...................................................................................... 8
2 - C - OPERATING CHARACTERISTICS ......................................................................... 9
FAD and power graph : ............................................................................................. 10
3 - DANGER SIGNALS .....................................................................................11
Danger zones : ..........................................................................................................11
4 - LAYOUT ...................................................................................................... 12
Internal view : ........................................................................................................... 13
5 - STORAGE ................................................................................................. 14
5 - A - UNDER 3 MONTHS .............................................................................................. 14
5 - B - 1 YEAR MAXIMUM ................................................................................................ 14
5 - C - OVER 1 YEAR AND EACH SUCCESSIVE YEAR ................................................. 14
5 - D - STORAGE OIL ....................................................................................................... 14
6 - INSTALLATION ......................................................................................... 15
Installation example : ................................................................................................ 15
7 - USING THE COMPRESSOR FOR THE FIRST TIME................................ 16
7 - A - SAFETY REMINDERS .......................................................................................... 16
7 - B - SAFETY MEASURES ............................................................................................ 16
7 - C - FIRST START- UP ................................................................................................. 17
7 - C - 1 REMOVAL FROM STORAGE......................................................................... 17
7 - C - 2 COUPLING MOUNTING................................................................................ 17
7 - C - 3 DIRECTION OF ROTATION .......................................................................... 19
7 - C - 4 STARTING PROCEDURE ............................................................................. 20

Page 4
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
Manual G06
Edition: 10/2015 - rev A
SUMMARY
8 - SAFETY INSTRUCTIONS .......................................................................... 21
Before any adjustments : .......................................................................................... 21
9 - PREVENTATIVE MAINTENANCE .............................................................. 22
9 - A - DAILY...................................................................................................................... 22
9 - B - EVERY 25 HOURS ................................................................................................ 22
9 - C - AFTER THE FIRST 50 HOURS ............................................................................. 22
9 - D - EVERY 250 HOURS .............................................................................................. 22
9 - E - EVERY 500 HOURS OR EVERY YEAR ................................................................ 22
9 - F - EVERY 1500 HOURS ............................................................................................ 22
9 - G - EVERY 3000 HOURS ............................................................................................ 23
9 - H - EVERY YEAR ........................................................................................................ 23
10 - MAINTENANCE ....................................................................................... 24
Tightening torque :.................................................................................................... 24
10 - A - COMPRESSOR LUBRICATION .......................................................................... 24
General characteristic of recommended oil : ........................................................... 25
10 - B - CYLINDER HEADS & VALVES ................................................................................ 26
10 - B - 1 - MAINTENANCE OF VALVES ..................................................................... 27
Dismounting of valves : ........................................................................................... 27
Remounting of valves : ............................................................................................. 27
Tightening of the valve nuts : .................................................................................... 27
Frequency :............................................................................................................... 27
10 - C - MOVING PARTS .................................................................................................. 28
Dismounting of the crankshaft : ................................................................................ 28
Remounting of the crankshaft : ................................................................................. 29
Fitting of crankshaft - connecting rod - piston shaft : ............................................... 29
10 - D - CYLINDERS - PISTONS ..................................................................................... 30
10 - E - PISTON RINGS................................................................................................... 30
Check the play at cut of the piston rings : ................................................................. 30
10 - E - 1 - MOUNTING OF RINGS .............................................................................. 31
General arrangement of piston rings : ...................................................................... 31
mounting of scraper piston rings :............................................................................ 31
mounting of anti-leak piston rings : ........................................................................... 31
Ovality of cylinders : ................................................................................................. 32
Position of rings : ...................................................................................................... 32

Page 5
Manual G06
Edition: 10/2015 - rev A
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
SUMMARY
Mounting of cylinders :.............................................................................................. 32
Wear of the piston ring grooves :.............................................................................. 32
11 - FAILURE ANALYSIS ................................................................................ 33
11 - A - START UP FAILURE............................................................................................. 33
11 - A - 1 - THE COMPRESSOR DOES NOT START ................................................. 33
11 - B - RUNNING FAILURE ............................................................................................. 33
11 - B - 1 - THE COMPRESSOR STARTS BUT TRIPS ............................................... 33
11 - B - 2 - THE COMPRESSOR RUNS BUT THERE IS NO DELIVERY PRESSURE 33
11 - B - 3 - THE COMPRESSOR OVERHEAT ............................................................. 33
12 - SPARE PARTS LIST ................................................................................ 34
12 - A - RECOMMENDED SPARE PARTS ....................................................................... 34
13 - EXPLODED VIEW AND PARTS LIST ...................................................... 35
13 - A - GENERAL ASSEMBLY ......................................................................................... 35
13 - B - VENTILATION ASSEMBLY .................................................................................. 36
13 - C - HIGH PRESSURE ASSEMBLY ........................................................................... 38
13 - D - LOW PRESSURE ASSEMBLY ............................................................................ 40
13 - E - PISTON DRIVE ASSEMBLY ................................................................................ 42
13 - F - CASING COVER .................................................................................................. 44
13 - F - 1 WITHOUT INTEGRATED REGULATION ..................................................... 44
14 - TOOLS ...................................................................................................... 46
14 - A - GENERAL RECOMMENDATIONS ..................................................................... 46
14 - B - LIST OF TOOLS RECOMMANDED .................................................................... 47

Page 6
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
Manual G06
Edition: 10/2015 - rev A
1 - GENERAL PRESENTATION
We thank you first of all for buying our type G06 compressor and remind you that ERVOR compressor
s have a tradition for quality and reliability which makes them unique in their range.
This manual is considered an integral part of your new compressor. Always keep it with the compressor
where you or any other operator can easily and quickly refer to it.
Read this manual and make sure you understand it fully before operating your compressor. It can
help you avoid making mistakes in its operation.
Pay special attention to the points marked . These points deal with operations which can
cause damage or injury if the instructions are not followed.
Always follow the instructions given in this manual. They will help you get the best use and efficiency
from your new compressor.
If repair is needed, use only ORIGINAL SPARE PARTS to ensure that your compressor continues
to work efficiently for an extended working life.
!

Page 7
Manual G06
Edition: 10/2015 - rev A
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
AIR COMPRESSOR
EXCLUSIVELYNON BREATHABLE AIR
!
IN THE CASE OF PURCHASE OF ONLY A COMPRESSOR HEAD, THE
CUSTOMER MUST EQUIP THE COMPRESSOR WITH A CALIBRATED
SAFETY VALVE.
!
1 - A - WARRANTY
)The use of this compressor is reserved only for pneumatic starting of DIESEL engines or Gas
engines, for all other uses, please consult us.
)This compressor has been specifically designed for the compression of air with an optimal
working ratio of 1/3 - 2/3 (working/stop).
)It is guaranteed for one year against faulty construction and defective material, provided that
the user complies with the instructions given in this manual.
)The Ervor guarantee only covers the free replacement of parts that have been proved defective
by our Technical Department.
)The guarantee does not cover breakdowns due to lack of maintenance or the non-compliance
of instructions given for correct running of the compressor.
It is the user's responsibility to guarantee against any electrical incidents by installing and
correctly connecting and mounting safety devices.

Page 8
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
Manual G06
Edition: 10/2015 - rev A
2 - TECHNICAL CHARACTERISTICS
2 - A - TECHNICAL DESCRIPTION
- Reciprocating air compressor with lubricated stroke
- Maximum Output Pressure .......................................... 40 bar
- Service Pressure ........................................................ 0 to 40 bar
- Low pressure cylinder bore ......................................... 125 mm
- High pressure cylinder bore ........................................ 50 mm
- Piston stroke .............................................................. 38 mm
- Revolution speed: -Maximum : 1500 rpm
-Minimum : 600 rpm
- Forced air cooling by outward-flow turbine
-heat abstraction : 5.1 kW
4000 kCal/h
- Cooling ...................................................................... copper coil between stages
- Oil Splash Lubrication
- Powered by electric motor or combustion engine (petrol or diesel)
- Direct coupling with semi-elastic blades or indirect coupling by drive pulley and belts
- Ambient temperatures for operation with standard equipment from -10°c to +40°c
- Weight with AC2 coupling ........................................... 60 Kg approx
- Oil capacity ................................................................ 1.9 Litres approx
2 - B - MATERIAL DESCRIPTION
Casing :
Cast iron. Large oil capacity. Oil fill in top.
Dust-proof. Oil level sight glass.
Vent pipe from casing to the air filter.
Crankshaft :
Steel, with double bearing, and counterweight.
Connecting rod :
Aluminium, free moving on the crank shaft with bronze bush.
Piston :
Aluminium monobloc piston. Large bore, short stroke and low linear velocity.

Page 9
Manual G06
Edition: 10/2015 - rev A
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
Cylinders :
Cast iron. Low pressure and high pressure cylinders are directly exposed to the ventilation air
flow. Highly efficient cooling system by cooling vanes.
Cylinder head :
Steel, equipped with intake and compression valves.
Valves :
Intake and compression valves are made of annular discs which operate automatically.
Manifold :
Aluminium manifold for improved cooling with integrated pulsation damper.
Cooling :
Efficient cooling ensured by light alloy turbine and Polycarbonate cowling.
2 - C - OPERATING CHARACTERISTICS
Working at
1500 rpm
( 50Hz )
Discharge pressure
30 bar 40 bar
Nominal flow (Nm³/h)
according to ISO 1217 31 ±5% 30.5
±5%
Power consumption (KW) 6.8 7.1
Power (KW) 7.5 7.5
Average temperatures at the
air outlet for an average
ambient temperature of 25°c
- 1
st stage
- 2
nd stage
95°c
165°c
105°c
185°c

Page 10
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
Manual G06
Edition: 10/2015 - rev A
FAD and power graph :
Ambient temperature =25°C
Flow Power / Pressure
4,2
5,2
5,55
5,95
6,4
6,65
6,8
6,95
7,05
40
36
33,5
32,5
32,3
31,8
31,32
31,05
30,8
0
5
10
15
20
25
30
35
40
Pressure (bar)
FAD (m³/h)
power consumption (kW)
G06 Pressure
(bar)
FAD
(m³/h)
FAD
(Litres/h)
Power
consumption
0 40 665 4,2
5 36 600 5,2
10 33,5 560 5,55
15 32,5 540 5,95
20 32,3 538 6,4
25 31,8 530 6,65
30 31,32 522 6,8
35 31,05 518 6,95
40 30,8 514 7,05
Table des matières
Autres manuels ERVOR Compresseur d'air
Manuels Compresseur d'air populaires d'autres marques

Campbell Hausfeld
Campbell Hausfeld RP3300 Guide de démarrage rapide

Ingersoll-Rand
Ingersoll-Rand UP6 20 HP Manuel utilisateur

Hitachi
Hitachi EC99S Manuel de l'opérateur

Parkside
Parkside PKO 270 A1 Manuel utilisateur

Sullair
Sullair 185 Manuel utilisateur

Clas Ohlson
Clas Ohlson QIE-ZTH-15 Manuel utilisateur