12
Complete programming chart
D1 D2 Parameter D3 D4
Pre-
determined
option
Options or values
C1Motor turning direction 01x
02
4Disabled
5Closing safety device (photocell or strip) 00xDevice not installed
10 Device without testing
11 Device with testing
P1Total opening radio code programming oç
2Disabled
3Door open/close programming oç
F1Functioning mode 01 Automatic
02xStep-by-step
2Standby in automatic mode 0...5. 0...9 15 59 = 59 sec; 2.5 = 2 min. 50 sec., etc
3Disabled
A0Flashing light 01xNo pre-warning
02 With pre-warning
1Garage light time 0...5. 0...9 03 59 = 59 sec; 2.5 = 2 min. 50 sec., etc
2Door speed 0 1...5 03 01: minimum speed;
05: maximum speed
3Slowdown speed 0 1...5 03 01: minimum speed;
05: maximum speed
4Slowdown distance 0 0...5 00 00: minimum distance;
05: maximum distance
5Disabled
6Maximum thrust
maximum thrust in opening 1...9 X 6X 1X: minimum thrust (in opening);
9X: maximum thrust (in opening)
maximum thrust in closing X 1...9 X6 X1: minimum thrust (in closing);
X9: maximum thrust (in closing)
7Closing photocell used during standby (in
automatic mode only)
01 Immediate close
02xRestart standby time
03 Has no effect
8Pushbutton operation during standby (in
automatic mode only)
01 Immediate close
02xRestart standby time
03 Has no effect
9Opening mode 01xOpening in accordance with the mode
selected in the main functions (F)
02 Collective opening (the control board
does not obey the key commands during
opening)
03 Step-by-step opening (the door halts if a
key device is activated during opening.
The door closes when operated again)
ç1Operations carried out XX Indicates the cycles completed,
multiplying the indicated figure by an
amount, for example:
68 indicates 6,800 cycles completed
6.8 indicates 68,000 cycles completed