EP Solar MT50 Manuel utilisateur

INSTRUCTION MANUAL
Remote Meter: MT50
Thank you very much for selecting our product!
This manual offers important information and suggestions with respect to
installation, use and troubleshooting, etc. Please read this manual carefully before
using the product.
书籍1.indb 1 2013-10-18 15:04:18

书籍1.indb 2 2013-10-18 15:04:18

Remote Meter
MT50
Remote meter (Model MT50) is available to connect with
solar controllerLSxxxxB、VSxxxxB and TracerxxxxB.
书籍1.indb 3 2013-10-18 15:04:18

1 Important Safety Instructions
..................................... ................. 1
2 General Information
............................................................................. 1
2.1 Features ................................................................................................. 1
2.2 Main functions ....................................................................................... 2
2.3 Recommendations ................................................................................. 3
3 Installation
................................................................................................ 3
4 Product Features
................................................................................... 7
4.1 Monitoring screen ............................................................................... 10
5 Operation
................................................................................................. 11
5.1 Buttons ................................................................................................ 11
5.2 Main menu .......................................................................................... 12
5.3 Real-time monitoring ........................................................................... 12
5.4 Device Information ............................................................................... 14
5.5 Test Operation ...................................................................................... 14
5.6 Control Parameter ............................................................................... 15
5.7 Load Setting ......................................................................................... 19
5.8 Device Parameter ................................................................................. 23
5.9 Device Password ................................................................................. 24
5.10 Charge mode .................................................................................... 24
5.11 Factory reset ...................................................................................... 25
5.12 Failure Information ............................................................................ 25
5.13 Meter parameter ................................................................................ 26
6 Technical Specications
................................................................ 27
Contents
书籍1.indb 4 2013-10-18 15:04:18

1 Important Safety Instructions
SAVE THESE INSTRUCTIONS:
This manual contains important safety, installation and operating
instructions for the Remote Meter.
General Safety Information
■ Please inspect the MT50 thoroughly after it is delivered. If any damage is
seen, please notify the shipping company or our company immediately. A
photo of the damage may be helpful.
■ Read all instructions and cautions in the manual before starting the
installation.
■ Keep the MT50 away from rain, exposure, severe dust, vibrations,corrosive
gas and intense electromagnetic interference.
■ Do not allow water to enter remote meter.
■ There are no user serviceable parts inside the controller. Do not
disassemble or attempt to repair it.
2 General Information
2.1 Features
The new-generation remote display unit MT50 for LSxxxxB、VSxxxxB and
TracerxxxxB controllers is an associated display device which supports both
1
书籍1.indb 1 2013-10-18 15:04:18

the latest communication protocol and the voltage technology standard of
solar controllers. The products have many excellent functions:
■ Automatic identify and display the type, model and relevant parameter
data of controllers;
■ Real-time display the operational data and working status of the connection
devices in digital, graphic and textual forms by a large-screen multifunction
LCD;
■ Direct, convenient and rapid operation of six navigation function keys;
■ Both data and power owing on the same lead, no need for external power;
■ Real-time data monitoring and remote load switchover of the controllers,
and data browse and modication of device parameters, charge control
parameters and load control parameters;
■ Real-time display and acoustic alarm of failure information of the
connection devices;
■ Longer communication distance based on RS485.
2.2 Main functions
Functions like the real-time monitoring of the operational data and working
status of a controller, the browse and modification of charge/discharge
control parameters, the setting of device parameters and load control
parameters and the restoration of factory defaults, based on LCD display
and functional key operation.
2
书籍1.indb 2 2013-10-18 15:04:18

2.3 Recommendations
■ Please conrm that MT50 is only allowed to connect with our LSxxxxB、
VSxxxxB and TracerxxxxB series controllers before purchase;
■ Please do not install MT50 in a situation with strong electromagnetic
interference.
3 Installation
mm(inches)
Frame Mount Dimensions
3
书籍1.indb 3 2013-10-18 15:04:18

Wall installation steps
Step1: Locate and drill screw holes
based on the Frame Mounting dimension
of the base, and erect the plastic
expansion bolts;
Step 2: Use four ST4.2×32 self-tapping
screws to x the Frame;
Frame Mounting
4
Mechanical
Parameter
Parameter
Overall
dimension
114 x 114 x 32.7mm
4.49 x4.49 x 1.29inches
Mounting
dimension
88.6x 88.6mm
3.49 x 3.49inches
Terminal
Φ4.3
书籍1.indb 4 2013-10-18 15:04:19

4
Step 3: Use four M4×8 pan head screws to mount MT50 Surface on the
Frame;
Step 4: Mount the four associated screw plugs into the screw holes.
5
Surface Mounting
书籍1.indb 5 2013-10-18 15:04:19

Steps of Surface mounting:
Step 1: Locate and drill screw holes based on the installation size of the
Surface;
Step 2: Use four M4×8 cross recessed pan head screws with M4 nuts to
mount MT50 Surface onto the panel;
Step 3: Mount the four associated white screw plugs into the screw holes.
Notice: Take full consideration of the plugging/unplugging space of the
communication cable and the length of the cable during installation to
see if they are appropriate.
6
Surface mounting
书籍1.indb 6 2013-10-18 15:04:20
Autres manuels pour MT50
1
Table des matières
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur