Quick Start
This new version of Accessor features several enhancements:
... the ability to add new users at the unit, without a PC
... any Level 1 Master code can now be used to mount or
unmount the unit from its mounting bracket
... added the Level 4 Lockout Mode (in lieu of Privacy)
Please follow the steps below to get your new Accessor
up and running as smoothly & easily as possible.
1) Unpack the Accessor and attach the mounting bracket to a
suitablelocation.Gateunitsmustberemovedfromthemounting
bracket prior to installation, see section 3 page 11.
2) New codes may be added at the box (see step 3) or by using
ACE ™ version 1.30 or greater. ACE ™ is available via a free
download at our website, engsolinc.com.
3) Program in new codes at the unit as follows:
... add a new Level 1 Master
(remember this code)
FCN →→
→→
→1234567 →→
→→
→New Master →→
→→
→1 →→
→→
→FCN
... test new Level 1 Master by deleting default Level 1 Master
FCN →→
→→
→New Master →→
→→
→1234567 →→
→→
→FCN
... confirm the default Level 1 Master is deleted
1234567 (unit should beep & illuminate the red LED)
... add any other new codes you need
(repeat as needed)
FCN →→
→→
→New Master →→
→→
→New Code →→
→→
→Level (1-4) →→
→→
→FCN
4) Mount the Accessor on its mounting bracket:
... enter your new Master code & lift open the keybox
... position unit on the mounting bracket, then while holding
the keybox open re-enter the new Master code
FCN →→
→→
→New Master →→
→→
→FCN
... slide the unit down, after 10 seconds the latch will move
out of the way allowing the keybox to relock
Congratulations! Your Accessor is ready to go!

4
Contents
Quick Start ..........................................................5
Introduction.........................................................5
Section 2: Installation .............................................7
Key Caddy and Key Hook ........................................ 7
Electric Strike.......................................................... 7
Gate/Fence .............................................................. 9
Padlock/Fence......................................................... 10
Section 3: Mounting the Accessor...............................12
Section 4: Basic Operations ......................................14
Using the Unit......................................................... 14
Adding a User at the Accessor................................ 15
Deleting a User at the Accessor .............................. 16
Level 4 Lockout Mode............................................. 16
Tamper Lockout...................................................... 17
Accessing the Serial Connector .............................. 17
Section 5: Batteries ................................................18
Jumpstarting the Accessor ..................................... 19
Section 6: Replacing the Key Caddy Recoil................20
Appendix A: Troubleshooting ....................................22
Appendix B: Specifications.......................................25
Appendix C: Limited Warranty ...................................30
Index .................................................................32

5
Introduction
This manual covers the installation and basic
operationofthe
Accessor4000,
acompleteDigital
Access Control system. The system is comprised
of two parts:
1. The Accessor4000 access control box.
2. TheoptionalACE™PCsoftwarewhichisusedto
create a user database, access schedules and
retrieve and store audit trail logs from multiple
Accessors.ACE™isavailablefreeviadownload
at our website “engsolinc.com”.
Shipping Contents
• Owner’s Manual
• Mounting Bracket
• 1” Lag Screws (4)
• Allen Wrench (for removing the cover)
• Jumpstart Cable
KeyBox
Jumpstart Cable
Mounting
Bracket
Key Compartment
Jumpstart
Connector
Cover
123
456
789
F0C

6
Also included with the Gate/Fence model:
• Weather Vandal Housing & Shackle
assembly
• Fence Mounting Plate
• Hardware bag including:
(4) 1 1/2” Hex Bolts
(4) 1 3/4” Hex Bolts
Also included with the Padlock/Fence model:
• Weather Vandal Housing
• Fence Mounting Plate
• Hardware bag including:
(4) 1 1/4” Hex Bolts
(4) 1 1/4” Lag Screws
Tools needed:
• 3/8” wrench
• Phillips Screwdriver
(Gate/Fence model only)

7
Section 2: Installation
Key Caddy and Key Hook
1. Attachthemountingbracketwiththefourscrews
provided,thenmounttheAccessoronthebracket
as described in Section 3, page 10.
2. Enter your access code (or try the default Level
1 code, 1234567) and lift the keybox to gain
access to the key compartment.
Attaching the Key
Key Caddy
1. Assemble as shown in diagram below.
2. While holding assembly in place, squeeze the
rivet “drive pin” into rivet housing using a pair of
pliers squeezing A towards B.
Key Hook
1. Hang the key on the “J” hook.
Electric Strike
1. Attachthemountingbracketovertheopeningin
the wall with the four screws or bolts provided.
Rivet
Washer
“U” bracket
Key Drive Pin
BA

8
2. Thread wires through the hole in the mounting
bracket and wall (or door) and mount the
AccessoronthebracketasdescribedinSection
3, page 10.
3. Hang the key on the “J” hook.
4. Connect the wires as shown below.
For Fail Unlocked —
Connect the white wire to the electric strike.
Accessor
wall/door
hole for wires
wires to be
connected
mounting bracket
Accessor
red
white
black
NO
common
NC
+12V/+24V
AC or DC GND
electric strike
This is an example of Fail Unlocked.

9
For Fail Secure —
Connect the red wire to the electric strike.
Caution: Be sure the unused wire
from the Accessor will not come in
contact with any metal surface.
Gate/Fence
There are 2 assemblies (a) and (b):
(a) Pre-assembled Vandal housing, mounting
bracket and shackle assembly
(b) Fence plate with 4 threaded holes
To install —
1. Position fence plate on the back side of the
fence.
2. Position vandal housing assembly on the front
123
456
789
F0C
Vandal Housing
Mounting
Bracket
Fence Plate
Shackle
Pre-assembled (a) Hex Bolts
Shackle Release
Screw

10
side of the fence.
3. Align the 4 holes, then screw the 2 assemblies
together using the hex bolts provided.
4. Unscrewtheshacklereleasescrew;theshackle
willdropdown,completelyexposingbothprongs.
5. Placeoneend of thechainoverthe left (longer)
prong. Push the shackle up and retighten the
screw.
6. MounttheAccessoronthemountingbracketas
described in Section 3, page 10.
To operate —
1. Enter your access code.
2. Lift open the keybox and pull the pin.
3. The shackle drops down to free one end of the
chain (other end is secured during installation).
4. When finished, loop the chain back over the
shackle then push shackle up into Accessor
until it locks into place.
Padlock/Fence
To install —
1. Position fence plate with 4 threaded holes on
the back side of the fence.
2. Place vandal housing against the front side of
the fence.
3. Positionthemountingbracketinsidethevandal
housing.