Eneo IAM-6MC1001M0A Manuel utilisateur

EN
User Manual
Ethernet over Coax Transceiver
Data/Power supply 270Mbps,
57VDC power input
IAM-6MC1001M0A

Safety instructions
•Before switching on and operating the system, first read this safety advice and the operating instructions.
•Keep the operating instructions in a safe place for later use.
•Installation, commissioning and maintenance of the system may only be carried out by authorised individuals and in
accordance with the installation instructions - ensuring that all applicable standards and guidelines are followed.
•Protect the devices from water penetration and humidity, since these can cause lasting damage.
•Should moisture nevertheless enter the system, under no circumstance switch on the devices under these conditions,
instead send them for examination to an authorised specialist workshop.
•The system must never be used outside of the technical specifications, since this can destroy it.
• The device must be protected from excesses of heat, dust, humidity and vibration.
• When separating the system from the voltage supply, only ever use the plug to pull out the cable. Never pull directly on the
cable itself.
• Lay the connecting cables carefully and check that they are not mechanically stressed, kinked or damaged and that no
humidity can penetrate into them.
• In the event of a malfunction, please inform your supplier.
• Maintenance and repairs may only be carried out by authorised specialist personnel.
• The system must be isolated from the power supply before opening the housing.
• The device may only be opened by qualified service personnel. Unauthorised access invalidates any warranty claim.
• Connection cables should always be exchanged through Videor E. Hartig GmbH.
• Use only original spare parts and accessories from Videor E. Hartig GmbH.
• The housing should only be cleaned using a mild domestic cleaning agent. Never use solvents or petrol as these can
permanently damage the surface.
• During installation, it is essential to ensure that the seals provided are correctly installed and that they are not displaced
during installation. Damaged seals must not be installed and will invalidate any warranty.
• The installer is responsible for the maintenance of the enclosure as per the technical data, e.g. by sealing the cable outlets
with silicone.
• Wire end ferrules should be used when shortening the flexible connection cables.
• The devices may only be operated in the temperature range indicated in the data sheet and within the defined air humidity
range.
WEEE (Waste Electronical & Electronic Equipment)
Correct Disposal of This Product (Applicable in the European Union and other European countries with separate collection
systems).
This marking shown on the product or its literature, indicates that it should not be disposed
with other household wastes at the end of its working life. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate this from
other types of wastes and recycle it responsibly to promote the sustainable reuse of
material resources. Household users should contact either the retailer where they purchased this
product, or their local government office, for details of where and how they can take this
item for environmentally safe recycling. Business users should contact their supplier
and check the terms and conditions of the purchase contract. This product should
not be mixed with other commercial wastes for disposal.

1. Quick Installation Guide ................................................................................... 3
1.1. Package Contents ...........................................................................................................................3
1.2. Overview .........................................................................................................................................3
1.3. Features.........................................................................................................................................3
1.4. Hardware Overview ........................................................................................................................4
1.5. Product Installation Guide...........................................................................................................5
1.6. Product Application .....................................................................................................................5
1.8. LED Indicators .................................................................................................................................6
1.9. Specification ..................................................................................................................................6
1.10. Caution .......................................................................................................................................7
1.11. Warranty....................................................................................................................................7
2. Pre-field verification ......................................................................................... 8
2.1. Check transmission line .................................................................................................................8
2.2. Check grounding and potential difference ..............................................................................12
2.3. Site environment review ..............................................................................................................12
3. Equipment Installation Guide ........................................................................ 13
3.1. Selection of installation equipment ..........................................................................................13
3.2. Transmission rate / PoE output ..............................................................................................14
3.3. LED operating status .................................................................................................................15
3.4. Grounding and Potential Difference .....................................................................................16
3.5. Apply Surge Protector ...............................................................................................................16
4. Troubleshooting FAQ..................................................................................... 17
4.1. EPoC transmission equipment ...................................................................................................17
Contents

Quick Installation Guide — 3
1. Quick Installation Guide
1.1. Package Contents
EPoC Transceiver DC Cable &
DC Terminal Block Quick Installation Guide
Quick Start
Guide
1.2. Overview
This device is a High-Speed, long distance Ethernet & PoE extender that makes possible to transmit IP data up to
2.4Km and PoE up to 1.2Km through various analog cables in different situations.
It is cost-effective and time saving solution to migrate existing analog system to IP based system since EPoC
Transceiver supports easy installation utilizing the existing CCTV cable (Coax, UTP, 2wire & Etc.).
With long distance transmission feature, the device makes to overcome 100 meters distance limitation easily and
reduces the construction cost significantly compared with fiber optic configuration.
1.3. Features
•Ethernet and Power over coax (UTP, 2-Wire)
communication following IEEE1901 Standard
•Data + Power over Coax (or UTP, 2-wire)
•Data distance up to 2.4Km
•PoE distance up to 1.2Km
•Max. 270Mbps Bandwidth
•10/100/1000 Full Duplex
•128bit AES network encryption
•Supports Multi-connection (Daisy chain, Star, etc.)
•Supports UTP, Telephone (2 Pairs), 2-Wire
cable communication (Using BTE Series)
•Quality LED (Data & Power)
•Plug & Play
•Surge Protection
•12VDC output (for Non-PoE Camera)

Quick Installation Guide — 4
1.4. Hardware Overview
BNC connector
DC Power Jack
Status LED indicator
Join Button
DC OUT LED Terminal Block
Right
Left
EPoC Transceiver
EPoC Transceiver
RJ45 DC OUT
ON / OFF Switch
Note: The Join Button is currently disabled.

Quick Installation Guide — 5
1.5. Product Installation Guide
1. Set the IP address on the camera following the instruction manual of the camera.
hIf the camera IP is automatically assigned (DHCP, etc.), there is no need to set the camera IP
separately.
2. Connect BNC of the coaxial cable to each EPoC Transceiver.
3. Connect 56V DC power to EPoC Transceiver first and then to AC outlet.
4. When they are correctly connected, PWR/BNC Join/Quality PWR LED are on.
5. Fix up EPoC Transceiver where it should be placed.
6. Connect the UTP(LAN) cable between EPoC Transceiver and NVR first and then between EPoC Transceiver
and camera.
7. Connect DC Cable between camera and Terminal Block on EPoC Transceiver.
hMind the polarity (+/-) and tie up DC cable on the terminal block.
8. Ping test is recommended to confirm the whole network after installation.
9. Check the video signal on the monitor.
1.6. Product Application
12V DC OUT
Non-PoE IP
Camera
Coaxial
10/100 Ethernet
56V DC/1.2A
Power Supply
EPoC Transceiver
EPoC Transceiver
NVR
Network Switch

Quick Installation Guide — 6
1.8. LED Indicators
Indicator Color Function
BNC Join EPoC Devices connected
PWR 56VDC input connected
Quality
LINK Good data connection
Poor data connection
PWR Good power supply condition
Additional adapter required
Data Flashes when data is transferred
DC OUT DC OUT switch is ON
1.9. Specification
Model 1 Port Transceiver
Interface Coax 1 x 75Ω BNC (Female) - Ethernet over Coax (B-LinX)
Ethernet
1 x RJ45 - 10/100/1000 Base-T with Auto-detect MDIX
Transmission Rate 270Mbps Full Duplex (PHY: 500Mbps)
Transmission
Distance
Ethernet up to 2.4Km(RG-6)
PoE (PoC) up to 1.2Km (RG-6 / 7W camera)
LED Indication
Ethernet 1 x Data(Green)
EPoC 1 x BNC Join(Green)
Power 1 x PWR(Blue)
Link Quality 1 x Good(Green) / 1 x Bad(Red)
Power Quality 1 x Good(Green) : 40V~57V / 1 x Bad(Red) : 40V Under
12VDC out 1 x 12V DC OUT(Green)
Encryption 128-bit AES
Power
Input 57 VDC
DC Output DC12V / 2A
Mechanical Dimension 132(L) x 83(W) x 28(H)mm
Weight 198g
Environment
Operating Temp -20 ~ 60°C
Storage Temp -30 ~ 80°C
Relative Humidity
10% ~ 90%
Compliance Certification FCC, CE, KC, RoHS
Surge Protection
IEC 61000-4-5 4kV(1.2 / 50us), 2kA(8 / 20us)
Optional Accessories 56VDC / 1.2A External Power Supply

Quick Installation Guide — 7
1.10. Caution
•Please install the device following the installation guide.
•Do not touch the device and cable with wet hands.
•Keep away from moisture and shock.
•Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus that produce
heat.
•Indoor use only.
•Do not use for other purposes. (i. e. Connecting analog camera to BNC connector)
•Do not disassemble or modify this device.
•Do not put any sticker or paint on it.
•If this device is defective or malfunctioning, please unplug the power adapter immediately and contact dealer or
service center.
•Use only rated 56V power adapter specified by the manufacturer. Connect DC power to ECP-2701 first and then
to AC outlet.
1.11. Warranty
•This device has passed the quality control and product inspection.
•Please install and use according to the installation guide.
•The warranty period for this product is 36 months from the date of purchase.
•Any damages or breakage from user’s abuse, accident, modification or natural disasters will not be covered
manufacturer’s warranty.

Pre-field verification — 8
2. Pre-field verification
2.1. Check transmission line
2.1.1. Transmission line type
█ EPoC (Ethernet over Coax) Applicable
Coaxial cable
3C, 5C, 7C, 10C, RG58, RG59,
RG6, RG11, KX6, KX100, etc.
Ethernet over
Coax Transceiver
2-Wire
UTP cable
EPoC Transceiver
+ IAM-4MU1001M0
A

Pre-field verification — 9
2.1.2. Check whether the cable is disconnected / shorted
█ Test cable opens
1. Make a short the conductor and shield of the one side of the coax.
2.
Take the testing probe and connect its cords to the specific ends of multimeter (red positive into the ‘+’ marked jack
and black negative into the ‘COM’ jack) and Set the measurement type dial of the multimeter to Ω.
3. Touch one of the leads to the outer metal part of the BNC and the second to the center pin on the another side and
check the value.
4. If the value is significantly high such as Mega Ohm, it means the cable might be open.
5. If the value is lower than the expected loop resistance value, the cable might be shorted. (Normal loop resistance of
the cable in case of RG59 is about 8~10 Ω / 100 meter)
OFF DCV
DCA
A
COM
VΩ
OFF DCV
DCA
COM
AVΩ
█ Test for shorted or open
1. Make both ends of the coax free by disconnecting it from the device
2. Take the testing probe and connect its cords to the specific ends of multimeter (red positive into the ‘+’ marked
jack and black negative into the ‘COM’ jack) and Set the measurement type dial of the multimeter to continuity test.
3. Touch one of the leads to the outer metal part of the BNC and the second to the center pin. If you don’t hear any
sound, then it means the coax is not shorted.
OFF DCV
DCA
A
COM
Ω