Technical Information
Solimotion FTR20
Flow indicator for bulk solids
Compact measuring device for non-contact ow detection for bulk solids
Application
The FTR20 flow indicator for bulk solids is a non-contact
device based on microwave technology. It is ideally suited for
monitoring pneumatic and mechanical transport processes for
bulk solids. The compact device can be used wherever the cost-
effective monitoring of bulk solids movement is required.
Typical areas of application or bulk solids are:
• Building materials industry: Cement, plaster, wood chips etc.
• Chemical industry: Fertilizers, plastic powder, granules etc.
• Food industry: Coffee, tea, tobacco, cereals, malt etc.
• Energy production: Coal, carbon dust, fly-ash, coke etc.
Individual adjustments to the application are carried out
by means of configurable functions (including automatic
calibration). In addition, changes in the mass flow can be
analyzed by the optional 4 - 20 mA current output.
Device properties
• Detection range up to 20 m depending on the bulk solids
• Process temperatures up to +70 °C (+158 °F) or +450 °C
(+842 °F) with optional high temperature adapter
• Process pressure up to 680 kPa (6.8 bar) absolute or 2 MPa
(20 bar) absolute with optional high pressure adapter
• For use in hazardous areas (dust)
Your benets
• Compact device:
Sensor, transmitter and power unit are mounted in a
housing, which means less eort is required for installation
and mounting.
• The device can be used wherever cost-eective monitoring
of a mass ow (present or not present) is required.
• Flush-mounted installation, non-contact installation
possible
• Easy mounting using R 1½, 1½ NPT or G 1½ thread or a
suitable mounting bracket
• Electronics housing can be rotated by 360 °, allowing
orientation into optimum position aer installation
• Easy electrical connection using the connectors (optional
with suitable mating connectors or prefabricated connection
cables)
• Mechanical robustness
- No wear
- Process-wetted ceramic sensor diaphragm (optional)
- Long service life
- Maintenance-free
• Signaling of mass ow
• Adjustable sensitivity
• Compliant with ATEX, CSA and IECEx

2
Solimotion FTR20
Endress+Hauser
Document information ���������������������������������� 3
Display conventions ������������������������������������������������������������ 3
Function and system design ������������������������� 4
Measuring principle ������������������������������������������������������������ 4
Safety ������������������������������������������������������������������������������������ 5
Input ���������������������������������������������������������������� 6
Measured variable ��������������������������������������������������������������� 6
Measuring range (detection range) ����������������������������������� 6
Operating frequency ������������������������������������������������������������ 6
Transmitting power ������������������������������������������������������������� 6
Switching frequency ������������������������������������������������������������ 6
Antenna opening angle (3 dB) ������������������������������������������ 6
Detectable speed ������������������������������������������������������������������ 6
Output ������������������������������������������������������������� 7
Terminal and onnector assignment ����������������������������������� 7
Relay ������������������������������������������������������������������������������������� 7
Solid-state relay ������������������������������������������������������������������� 7
Current ���������������������������������������������������������������������������������� 8
Power supply �������������������������������������������������� 9
Terminal and connector assignment ��������������������������������� 9
Supply voltage ���������������������������������������������������������������������� 9
Power consumption ������������������������������������������������������������� 9
Potential equalization ��������������������������������������������������������� 9
Terminals ����������������������������������������������������������������������������� 9
Cable entries ���������������������������������������������������������������������� 10
Device connector ���������������������������������������������������������������� 10
Cable specication ������������������������������������������������������������� 10
Performance characteristics ����������������������� 11
Reference operating conditions ��������������������������������������� 11
Inuence of ambient temperature ����������������������������������� 11
Inuences on bulk ow detection ������������������������������������ 11
Vibration eects ���������������������������������������������������������������� 11
Installation ��������������������������������������������������� 12
Mounting location ������������������������������������������������������������� 12
Orientation ������������������������������������������������������������������������� 12
Installation instructions ���������������������������������������������������� 12
Direct mounting with threaded connection �������������������� 14
Mounting in front of microwave-impermeable
process wall ������������������������������������������������������������������������ 15
Mounting in front of microwave-permeable sight
glass tting ������������������������������������������������������������������������� 16
Mounting on process nozzles ������������������������������������������� 17
Mounting with spacer tube (wave guide) ����������������������� 18
Mounting with high temperature adapter and
length extensions �������������������������������������������������������������� 20
Table of contents
Environment ������������������������������������������������ 21
Operating temperature range ������������������������������������������ 21
Storage temperature ��������������������������������������������������������� 21
Degree of protection ���������������������������������������������������������� 21
Vibration resistance ���������������������������������������������������������� 21
Electromagnetic compatibility (EMC) ����������������������������� 21
Process ���������������������������������������������������������� 22
Process temperature range ����������������������������������������������� 22
Process pressure range ����������������������������������������������������� 22
Vibration ���������������������������������������������������������������������������� 22
Mechanical construction ����������������������������� 23
Dimensions ������������������������������������������������������������������������ 23
Weight �������������������������������������������������������������������������������� 23
Materials ���������������������������������������������������������������������������� 24
Process connections ���������������������������������������������������������� 24
Operability ���������������������������������������������������� 25
Operating concept ������������������������������������������������������������� 25
Local operation ������������������������������������������������������������������ 26
Certicates and approvals ��������������������������� 28
CE mark ������������������������������������������������������������������������������ 28
Ex approval ������������������������������������������������������������������������� 28
Telecommunications ��������������������������������������������������������� 28
Other standards and guidelines ��������������������������������������� 28
Ordering information ���������������������������������� 29
Scope of delivery ���������������������������������������������������������������� 29
User-specic settings �������������������������������������������������������� 30
Accessories ��������������������������������������������������� 31
Supplementary documentation ������������������ 41
Standard documentation �������������������������������������������������� 41
Supplementary device-dependent documentation �������� 41

Solimotion FTR20
Endress+Hauser 3
Document information
Display conventions Safety symbols
Symbol Meaning
NOTICE!
This symbol contains information on procedures and other facts which do not
result in personal injury�
Electrical symbols
Symbol Meaning
Direct current
Alternating current
Direct current and alternating current
Protective Earth (PE)
A terminal which must be connected to ground prior to establishing any other
connections�
Symbols for certain types of information
Symbol Meaning
Tip
Indicates additional information�
Reference to documentation
Reference to page
Reference to graphic
Symbols in graphics
Symbol Meaning
1, 2, 3 ��� Item numbers
, , ��� Series of steps

4
Solimotion FTR20
Endress+Hauser
Function and system design
Measuring principle The FTR20 ow indicator for bulk solids works using microwave technology. A signal is transmitted,
and this signal is reected by the moving bulk solids. The FTR20 measures the strength of the
reected, frequency-shied (Doppler eect) energy, this is analyzed and put out via the display or
the signal output�
1 Measuringprinciple
The range of the FTR20 depends on the reection characteristics of the bulk solids.
Example of volumetric dosing
The FTR20 monitors the outow of a screw conveyor. If the ow of material slows down (for
example due to clogging of the pipe leading downwards or if there is no material being conveyed
due to a failure in the screw conveyor), the device generates a message to this eect. This can then
be processed further in the system�
2 Exampleofvolumetricdosing

Solimotion FTR20
Endress+Hauser 5
Example of a conveyor belt
The FTR20 monitors the continuous mass ow at a transition point, a break in the ow is detected
and put out at the signal output�
3 Exampletransitionpointmonitoring
The FTR20 monitors if there is material on the conveyor belt�
4 Exampleconveyorbeltmonitoring
For optimal installation in the process, the FTR20 devices of the microwave barrier can be extended
with corresponding accessories such as weld-in nozzles, sight glasses or high temperature adapters
for process separation (→ 31).
Safety We shall only grant a guarantee if the device is installed and operated in accordance with the
Operating Instructions� Safety measures in accordance with the user's safety standard, which provide
additional protection for the device and its signal transfer, are to be implemented by the user�

6
Solimotion FTR20
Endress+Hauser
Input
Measured variable Doppler frequency
Measuring range
(detection range)
With an unobstructed radiation path to the surface of the bulk solids, the maximum range is 20 m
depending on bulk solids (reection characteristics).
This is reduced if container walls, sight glasses or similar need to be penetrated�
Operating frequency 24�15 GHz ± 80 MHz
Transmitting power The power produced by the FTR20 is maximum 100 mW e�i�r�p� (equivalent isotrope radiation
performance)�
• Power density directly in front of the device: Approx� 1 mW/cm2
• Power density at a distance of 1 m: Approx� 0�3 µW/cm2
The power density is clearly below the recommended limit values of the ICNIRP guidelines
"Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic
Fields (up to 300 GHz)" and thus is completely harmless for humans�
Switching frequency max� 2 Hz
Antenna opening angle
(3 dB)
approx� ± 11 °
Detectable speed 0�09 ��� 62 m/s

Solimotion FTR20
Endress+Hauser 7
Output
Terminal and onnector
assignment
A ( 1 : 1 ) B ( 1 : 1 )
2
3
4
5
3
4
5
5 Terminalandconnectorassignmentoftheoutput
Relay • Potential-free change-over contact
• Switching capacity:
250 V / 4 A (Harting connector type HAN8D max. 50 V)
125 V / 0.4 A or 30 V / 4 A
• Contact material: AgCdO (gold-ashed)
• Switching frequency: max� 2 Hz
3 (NO)
4 (CC)
5 (NC)
Electrical connection Relay
Connection terminals Terminal 3 (NO) Terminal 4 (CC) Terminal 5 (NC)
M12 connector (Binder series 713/763) Connector 2
Terminal 2 (NO) Terminal 3 (CC) Terminal 4 (NC)
Harting connector type HAN8D Connector 2
Terminal 3 (NO) Terminal 4 (CC) Terminal 5 (NC)
• The contact material is also suitable for switching small signal circuits� However, this is possible
only if no inductive loads or higher currents have been switched previously�
• The solid-state relay can be used to evaluate higher switching frequencies�
Solid-state relay • Switching contact of a semiconductor relay
• Switching capacity:
30 V / 0.4 A
40 V / 0.4 A
• Switching frequency: max� 2 Hz
3
4
Electrical connection Solid-state relay
Connection terminals Terminal 3 − 4
M12 connector (Binder series 713/763) Connector 2, contact 3 − 4
Harting connector type HAN8D Connector 2, contact 3 − 4

8
Solimotion FTR20
Endress+Hauser
Current • Current output 4 ��� 20 mA
• Active
• Max. load: 600 Ω
A
+
-
4
3
Electrical connection Current output
Connection terminals Terminal 3 (+) − 4 (−)
M12 connector (Binder series 713/763) Connector 2, contact 3 (+) − 4 (−)
Harting connector type HAN8D Connector 2, contact 3 (+) − 4 (−)
The value of the current output corresponds to the signal strength�

Solimotion FTR20
Endress+Hauser 9
Power supply
Terminal and connector
assignment
A ( 1 : 1 ) B ( 1 : 1 )
2
3
4
5
3
4
5
6 Terminalandconnectorassignmentofthepowersupply
Electrical connection Power supply
Connection terminals Terminal 1 − 2
M12 connector (Binder series 713/763) Connector 1, contact 1 − 2
Harting connector type HAN8D Connector 1, contact 1 − 2
A suitable wire (→ 10) is used to connect the FTR20 to the power supply.
Supply voltage • 85 to 253 V, 50/60 Hz
• 20 to 60 V or 20 to 30 V, 50/60 Hz
• The polarity of the supply voltage can be set as required�
• When using the public powers supply, install an easy accessible power switch in the proximity of
the instrument. Mark the power switch as a disconnector for the instrument (EN/IEC 61010).
• You should use a fuse to protect the power supply against short-circuit�
• The electrical connection with Harting connector type HAN8D is only available for the power
supply with 20 ... 60 V or 20 ... 30 V, 50/60 Hz.
Power consumption • max. 4.8 VA ( 85 to 253 V, 50/60 Hz)
• max. 2.2 W ( 20 to 60 V) or 3 VA ( 20 to 30 V, 50/60 Hz)
Potential equalization Requirements:
• The potential equalization should be connected to the outer ground terminal�
• For optimum electromagnetic compatibility, the potential matching line should be as short
aspossible.
• The recommended minimum cable cross-section is 2�5 mm2�
• Potential equalization of the FTR20 should be incorporated in the local potential equalization�
For devices intended for use in hazardous locations, please observe the guidelines in the
Exdocumentation (XA).
Terminals Max� 1�5 mm2

10
Solimotion FTR20
Endress+Hauser
Cable entries • Cable gland M20 x 1�5 or cable entry ½ NPT
• Degree of protection: Min� IP66
• Cable gland in non-hazardous areas:
- Material: Plastic
- Color: Gray
- Clamping range: 5 to 10 mm (EN 61444) or 7-10 mm (UL-514 B)
• Cable gland in hazardous areas:
- Material: Nickel-plated brass
- Color: Silver
- Clamping range: 7 to 10�5 mm
• Quantity: 2 pieces per device
The cable gland is only admissible for the connection of fixed-installation lines and cables�
Theoperator must ensure corresponding strain relief.
Device connector • M12 connector (Binder series 713/763)
• Harting connector type HAN8D
• Suitable mating connectors are available as an order variant
(Ordering information → 30).
• Suitable mating connectors and prefabricated connection cables are available as accessories
(→ 32).
Cable specication • Normal instrument cable is sucient
• Conductor cross-section: max� 1�5 mm2
Autres manuels pour Solimotion FTR20
3
Table des matières
Autres manuels Endress+Hauser Écran tactile
Manuels Écran tactile populaires d'autres marques

IBASE Technology
IBASE Technology ASTUT-152-RE1S Manuel utilisateur

YASKAWA
YASKAWA TP 610C Manuel utilisateur

B&R
B&R Power Panel C Series Manuel utilisateur

Beijer Electronics
Beijer Electronics X2 control Manuel utilisateur

AXIOMTEK
AXIOMTEK GOT321W-521 Manuel utilisateur

TRIDONIC.ATCO
TRIDONIC.ATCO x-touchBOX Manuel utilisateur