Enconnex AC6000 Manuel utilisateur

Enconnex AC6000 UPS
USER MANUAL

Legal Disclaimer
This document is meant for instructional purposes only. This publication is not meant to
be a substitute for a detailed operational and site-specific development plan. Therefore,
Enconnex assumes no liability for damages, violations of codes, improper installation,
system failures, or any other problems that could arise based on the use of this
publication.
This publication has been compiled in good faith by Enconnex. However, no
representation is made, or warranty given, either expressed or implied, as to the
completeness or accuracy of the information this publication contains.
Enconnex reserves the right to make changes or updates with respect to or in the content
of the publication or the format thereof at any time without notice. Copyright, intellectual,
and all other proprietary rights in the content (including but not limited to software, audio,
video, text, and photographs) rests with Enconnex or its licensors. All rights in the content
not expressly granted herein are reserved. No rights of any kind are licensed or assigned
or shall otherwise pass to persons accessing this information.
This publication shall not be for resale in whole or in part

Table of Contents
Legal Disclaimer 1
Table of Contents 2
Figures 4
Tables 5
AC6000 Safety Information 6
Handling and Electrical Safety Information 6
Disclaimers 7
Life Support Applications 7
Product Introduction 9
Overview 9
AC6000 Features 10
Advanced Battery Management System 10
Automated Software Interface 10
User Interface - Front Panel with Bezel 11
Connectors and Controls - Rear Panel 12
Enconnex AC6000 Technical Specifications 13
AC6000 Installation Procedure 16
About this Procedure 17
AC6000 Mount Example 16
Materials Needed 17
Box Contents 17
Slide Rail Assembly (optional) 17
Instal the Inner Slide Rails on the AC6000 17
Installing the Outer Slide Rails 19
Field Wiring 19
Power-up and Shutdown Procedure 21
About This Procedure 21
Powering Up the AC6000 21
Visual Verification 29
Modes of operation 23
5.4.1 Standby Mode 23
5.4.2 NormalUPS Mode 23
Communicating with the AC6000 29
Webpage (HTTP) Configuration 24
SNMP Configuration 29

AC6000 Display 30
LCD Display Icons 30
Default Screen 30
Navigation 31
Main Menu 31
Reset to Factory Default Settings 35
Faults and Alerts 35
AC6000 Website 38
Home Page 38
Network Configuration 38
UPS Configuration 38
Control 38
System Status 38
DB9 and REPO Port Pin-Outs 39
REPO Connector 39
Serial Communication 39
Troubleshooting 40
Appendix 45
Safety Symbols and Definitions 45

Figures
Figure 2.1-1: AC6000 Drawing
Figure 2.1-2: AC6000 System Overview
Figure 2.5-1: AC6000 Front Panel Callouts
Figure 2.6-1: AC6000 Rear Panel
Figure 4.1-1: AC6000 Example Installation
Figure 4.4-1: Enconnex Adjustable Mounting Rails
Figure 4.4-2: Enconnex Adjustable Mounting Rails
Figure 4.4-3: Slide Rail Mounting.
Figure 4.4-4: AC600 Enclosure with optional Enconnex slide rails attached.
Figure 4.5-1: Hard-wiring inspection and assembly.
Figure 5.2-1: AC6000 Rear Panel
Figure 5.2-2: AC6000 Power Button Location
Figure 5.5-1: AC6000 Rear-Panel Communication Ports for Troubleshooting
Figure 6.3-1: AC6000 User Input Controls
Figure 6.4-1: AC6000 Front Panel Menu
Figure 8-1: Expansion Communication Ports and REPO Connector
Figure 8.1-1: REPO Connector Pin-Out
Figure 8.2-1: Serial and Ethernet Pin-Outs

Tables
Table 2.5-1: User Interface and Controls
Table 2.6-1: AC6000 Rear Panel Detail
Table 3-1: AC6000 Technical Specifications
Table 4.2-1: Materials Needed
Table 4.5-1: Field Wiring Table
Table 5.3-1: Icons and Descriptions
Table 5.5-1: Webpage Default Username and Password.
Table 5.5-2: Parameter Table
Table 6.4-1: Front Panel Menu
Table 6.6-1: AC6000 Beep Codes
Table 6.6-2: Beep Control Mode
Table 6.6-3: Fault Messages and Descriptions
Table 6.6-4: Display Messages and Descriptions
Table 9-1: Troubleshooting: Problems and Solutions
Table 9-2: Error Codes, Messages and Descriptions

1. AC6000 Safety Information
1.1. Handling and Electrical Safety Information
IMPORTANT SAFETY INSTRUCTIONS — SAVE THESE INSTRUCTIONS
This document contains important information and direction that should be followed
during installation, maintenance, and usage of this product. Before installing or operating
this equipment, please read all instructions, warnings and cautions. Save this manual for
future reference.
- DANGER
This UPS contains LETHAL VOLTAGES. All repairs and service should be performed only
by an Enconnex-AUTHORIZED SERVICE PERSONNEL.
Fuses are permanently installed. There are NO SERVICEABLE PARTS inside this product.
- WARNING
● Personnel should be knowledgeable of the processes before attempting to install,
configure or replace this equipment.
● It is important to note that this UPS contains its own energy source (lithium-ion cells).
Its output may produce high voltages and currents even when it is not connected to
AC mains.
● This system contains live batteries that may present a shock hazard even when
disconnected. Output safeguards such as disconnect switches, interlocks, etc. must
be provided by user.
● Connect only to a mains provided with branch circuit overcurrent protection. This
must be performed in accordance with the National Electrical Code® (NEC)
ANSI/NFPA 70 and applicable codes of local jurisdictions.
● Leakage current of this UPS and all connected equipment must not have an earth
leakage current greater than 3.5 milliamperes per international standards and wiring
regulations.
● For 230V/50Hz models, cables should not exceed ten meters in length.
● Lithium ion is a Class 9 hazardous material and must be shipped in accordance with
CFR 49. Please contact your Enconnex representative when shipping a unit for return
or other purposes.
● Contact Enconnex agent for service, recycling, and disposal instructions. Also visit
earth911.com for instructions on disposal.
● Damage will occur if the input or output AC terminals are shorted. Enconnex is not
responsible for damages to the UPS incurred in this manner.

- CAUTION
● Install this UPS in a clean, temperature- and humidity-controlled indoor location in
order to reduce the risk of fire or electric shock. Ambient temperature must not be
above 40°C (104°F) or below 0°C (32°F). Do not locate near water or excessive
humidity (95% maximum).
● It is advisable to not bring superfluous conductors into the installation area. Before
beginning maintenance or installation, please remove jewelry (e.g. watches, rings and
necklaces). Metal conductors have the potential to short between power terminals
(power and ground, commonly) and nearly instantly heat to very high temperatures
when connected between them. This can cause serious burns and/or weld a metal
object to the terminals.
● This system is cooled through forced air convection. Do not block air flow of fans and
allow adequate space on the front and rear of the unit for proper ventilation.
● This equipment has been tested and found to comply with the limits for a Class-A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
that the user must correct, including the expense of all corrective modifications.
● This system is suitable for IT (impedance-grounded) systems.
1.2 Disclaimers
Modification or changes to the AC6000 not performed or expressly approved by
Enconnex may void the unit's warranty.
The integral battery is not field-replaceable. There are no user-replaceable fuses within.
Contact Enconnex Customer Support for assistance.
The AC6000 is designed for installation in temperature-controlled, indoor areas free of
conductive contaminants. See Technical Specifications for more information.
1.3 Life Support Applications
The Enconnex AC6000 is not for use in life support applications where failure or
malfunctions of the unit can be reasonably expected to cause failure of the life support

device or to significantly affect its safety or effectiveness. The Enconnex AC6000 is not
for direct patient care.
Enconnex will not knowingly sell its products for use in such applications unless it
receives in writing assurances satisfactory to Enconnex.
The AC6000 does not meet medical standard requirements for use in direct patient care.

2. Product Introduction
2.1 Overview
The Enconnex AC6000 is a highly integrated line-interactive uninterruptible power
system (UPS). Integrating the electronics and a battery capable of supplying 6kWs of
power for 6 minutes contained within a small 2RU form factor, this system is designed
to protect servers in the back office and data center environments.
Figure 2.1-1: AC6000 Drawing
The line-interactive approach captures the best features of UPS topologies: Its
electronics are mostly inactive, but always “armed”. They’re at the ready for the next
power interruption. Switchover to UPS Mode occurs within ¼to ½cycle of the 60 Hz
mains.
This translates to full power available with an interruption of 4 to 8 thousandths of a
second. Most, if not all, IT equipment is designed to never notice this very high-speed
handoff.
Figure 2.1-2: AC6000 System Overview
The AC6000 is versatile and extensible. It can serve to supplement mains power
during peak energy consumption times using unique peak shaving technology. This
Table des matières
Manuels UPS populaires d'autres marques

Pylontech
Pylontech Victron & Pylontech US5000 Manuel utilisateur

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manuel utilisateur

Mecer
Mecer ME-1000-WTU Manuel utilisateur

Mustek
Mustek PowerMust 530(B) Plus Manuel d'installation et d'exploitation

Emerson
Emerson Liebert NXL series Manuel utilisateur

MAKELSAN
MAKELSAN BOXER SERIES Manuel utilisateur