EnaSolar immerSUN Manuel utilisateur

Installation and User Guide
®
DRAFT

2
Contents
Introducing the immerSUN 3
Main Screen 4
Savings 5
Boost (Manual) 6
Boost (Timed) 7
Menu 8
View Readings 10
Advanced Sengs 12
External Boost Input 13
Mulfunconal Relay 14
Installaon 16
System Overview 18
immerLINKTM Linking Units 19
immerSUN at a Glance 20
Electrical Connecons 22
Sensor Installaon 23
Setup 24
EnaSolar Monitoring and Reporng 26
Conguring an EnaSolar Site 27
Wiring Diagrams 29
Wiring: Single Heater 30
Wiring: Two Heater 32
Wiring: Three Heater 34
Wiring: Underoor Heang (opt. 1) 36
Wiring: Underoor Heang (opt. 2) 38
Wiring: Dual Tari (Single Meter) 40
Wiring: Dual Tari (Two Meter) 42
Wiring: Pool or Heatpump 44
Error Messages 46
Technical Specicaons 48
Site Installaon Details 49
immerSUN Controller Details 50
Notes 51

3
Introducing the immerSUN™
Thank you for choosing immerSUN - You have made an excellent choice!
The immerSUN is a Solar PV Self-Consumpon Controller for heaters. It tracks available surplus
power from a grid-ed PV or Wind turbine system and varies the power to the heater to match
the surplus power, therefore ensuring all of the green energy is fully ulised.
trusine™ Power Control Technology
The immerSUN uses TruSine™ power control technology. This means that the voltage is
very smoothly adjusted to alter the power to the heater. The power going to the load is
a non-distorted true sine wave, only the voltage is altered.
This control technology is unique to the immerSUN and is more sophiscated than any similar
product on the market. TruSine™ technology ensures trouble free operaon with all inverters
and compability with all import/export energy monitors.
Feature Set
● Tracks surplus power and diverts this energy to the load
● trusine™ technology for fast and smooth automac power adjustment
● Works with many microgeneraon systems including PV, Wind and Hydro systems
● Clear graphical backlit LCD display
● Indicates current import/export power levels as well as diverted power to the heater
● Savings are accurately reported for the day, month, year as well as the total since installaon
● Savings can be displayed in several currencies as well as kWhs
● No need to change immersion heater
● Works with many types of heater including storage, panel and underoor
● One immerSUN can control up to 3 heaters sequenally
● Only one current sensor for ease of installaon with the opon of a wireless sensor
● Built-in 7-day programmable boost mer
● Manual boost funcon for both heater outputs
● Integral mul-funcon relay to provide addional funcons such as: Economy-7
control, cylinder de-stracaon pump control and export power threshold detect
● Up to 5 immerSUN’s can be linked together for larger systems
● Smart, sturdy metal enclosure designed with the installer in-mind
● Fully short circuit protected in case of load fault
● Over load protecon
● So starng to avoid power surges
● Smart meter compable

4
Main Screen
The main screen shows the status of the immerSUN, the imported or exported power, the
date and me and the savings made today.
The house in the centre of the screen will be ‘happy’ if no power is being imported, otherwise
a straight face will be displayed. Arrows either side of the house show the direcon of power.
From this screen the Menu can be accessed, a manual Boost can be triggered and there is a
short-cut to the Savings data.
Savings Today
Savings shown alternates between
kWh and nancial savings in the set currency.
Date & Time
The current date, day
of week and me.
Grid Power
The power either, being
imported or exported.
Import or export is shown
by the direcon of the
arrow between the Grid
and House symbols.
Current Heater
The symbol for the heater
being heated is shown along
with the heater number.
Heater Power
The amount of power
currently being sent to
the heater.
BOOST
p6
MENU
p8
SAVINGS
p5

5
Savings
Savings that have been made by immerSUN are stored in permanent memory. The savings
can be shown for Today, this Week, this Month and this Year as well as the Total since the
immerSUN has been installed. The savings can be displayed as a list or in a graph.
The savings are shown in kWh as well as nancially in the chosen currency. For the nancial
savings to be correct, the user must keep the tari up to date. The Set Tari opon in the
Main Menu allows the user to set the current tari, this should be set to reect the kWh
cost for the fossil fuel normally used to heat the heater.
SAVINGS

6
Boost (Manual)
A heater can be ‘boosted’ to fuII power for a short period regardless of the amount of available
export power, this funcon is called Manual Boost and is acvated from the main screen. Once
the boost starts, the remaining boost period will be displayed, this will start at 1 hour but can
be adjusted during the boost. A manual boost can be cancelled at anyme.
Press
Boost Buon
Select
Heater
Adjust Boost
Period
(if desired)
BOOST
EXIT
Boost Opon
HEATER 1
Boost
HEATER 2
Boost
HEATER 3
Boost
CANCEL
Boost
INCREASE
Boost Period
DECREASE
Boost Period

7
Boost (Timed)
The immerSUN can be programmed to ‘boost’ the heang for each heater at certain mes.
Boost means that the heater will be at full power regardless of the amount of available export
power. This means that power may be drawn from the mains grid supply during boost mes.
The Boost Times can be accessed from the Main Menu.
Once in the BOOST TIMES screen, use the and buons to select the boost me you
wish to change, then press . You can now edit the boost mes, use the and buons
to change the start me, end me, days of the week and heater number for the boost,
(press the buon to move to next secon). Press the buon to exit edit mode.
Special heater types
There are two special heater types; T and B. These will only be available if the Mul Funcon
Relay is set to Export Threshold or Boiler Boost and wired correctly.
T: Export Threshold boost, the appliance will be acvated for the boost period.
B: Boiler boost, the boiler will be acvated for the boost period.
Important points
● Up to six dierent boost mes can be entered.
● Each week day can be individually selected for each boost me.
● Only ONE heater can be boosted at any one me.
● If any boost mes overlap, the latest med boost will take presidence.
● For boost mes crossing midnight, two me slots will need to be used.
MAIN MENU
Boost Times
MAIN MENU
Boost Times
BOOST TIMES
06:30-07:30 MTWTFSS - H
16:30-17:30 MTWTFSS - H
07:30-08:30 MTWTFSS - H
17:30-18:30 MTWTFSS - H
08:30-09.30 MTWTFSS - H
18.30-19.30 MTWTFSS - H
START
mes
END
mes
DAY of
week
HEATER
number or type

8
MAIN MENU
Savings
Boost Times
Holiday Mode
Set Date & Time
Set Display
SET DATE & TIME
Date: 16.02.14
Time: 11.34
Press
then use
to make changes.
SET BACKLIGHT
Buon Press: 30s
When Heang: ON
When Boosng: ON
Press
then use
to make changes.
SET CONTRAST
Contrast: 50%
Press
then use
to make changes.
SET DISPLAY
Set Backlight
Set Contrast
BOOST TIMES
06:30-07:30 MTWTFSS -
16:30-17:30 MTWTFSS -
07:30-08:30 MTWTFSS -
17:30-18:30 MTWTFSS -
08:30-09.30 MTWTFSS -
18.30-19.30 MTWTFSS -
HOLIDAY MODE
Press
to put unit in
standby.
Press to cancel.
SAVINGS
Today: 2.5kWh $0.63
Week: 16kWh $4.00
Month: 74kWh $18.50
Year: 315kWh $78.75
Total: 315kWh $78.75
Menu
The Menu is
accessed by pressing
the buon from
the main screen.
Use the and
buons to select
the required menu
item, then press the
buon to select
the menu opon.
Press the buon
to exit or go back
from a menu.
Boost Times
Boost mes can be set to turn on
the selected heater at full power
regardless of surplus export power
available.
Holiday Mode
The immerSUN can be set to Holiday
Mode, when you are away from
home. This will stop the immerSUN
from heang. The med boost will
also not operate.
Set Date & Time
The date me should be set during
installaon. Use this menu opon to
change the current date or me.
The Date and Time will be retained
during a power outage for at least
2 days.
Set Backlight
The display backlight can be set to
illuminate for a few seconds aer a
buon press.
Also the backlight can be set to
illuminate whenever the unit is
heang and/or boosng.
Set Contrast
The display contrast can be adjusted
if required
Savings
Savings made by the immerSUN are
accumulated. The savings are shown
in kWh as well as in currency. The
savings are displayed for Today, this
Week, Month and the Total this year.
The Total Savings since installaon
is shown. p5
p7

9
SET TARIFF
Current: $000.25
New: $000.25
From: 01/01/14
Press
then use
to make changes.
Set Tari
The tari should be set to that
shown on your ulity bill. You will
need to adjust the tari from me
to me as the tari changes. The
tari should be for the fossil fuel you
normally use to heat the appliance.
The NEW tari will take eect from
the date entered, which can be a
past or future date, meaning the
NEW tari does not need to be set
on the day it changes.
SET HEATER PRIORITY
Priority: 1-2-3
Press
then use
to make changes.
Lock Advanced
If cked the
Advanced Sengs
menu is locked, the
passcode will need
to be entered to
access the menu.
If the Advanced
Sengs menu is
unlocked, the menu
can be immediately
locked by selecng
this opon.
LOCK ADVANCED
VIEW CONFIGURATON
HEATER 1 TYPE
Immersion (Top)
HEATER 2 TYPE
Immerson (Boom)
HEATER 3 TYPE
Disabled
MINIMUM EXPORT: 50W
HEATER PRIORITY
1-2
RELAY FUNCTION
When heang
1,2
Include Boost
EXTERNAL BOOST
Boost Heater
1,2
SENSOR TYPE
Wired
immerLINKTM
Unit: Master
Slaves: 0
Channel: 1
Net ID: f428
Gateway PW:3b5b4436
Set Heater Priority
If two or three heaters are
connected, the heang sequence
can be selected.
The higher priority heater will be
heated unl the thermostat opens,
then the next priority heater will
start to be heated and so on. When
heang a lower priority heater, the
unit will switch back to the higher
priority heater periodically, this
period is set by Priority Check Period
in the Advanced Sengs menu.
If the heang priority is set to Equal,
then each heater will be heated in-
turn for the me set by the Priority
Check Period in the Advanced
Sengs menu.
View Conguraon
This screen gives an overview
of the immerSUN conguraon.
It is useful to check the current
sengs.
VIEW READINGS
p10
ADVANCED
SETTINGS p12
Set Tari:
Set Priority: 1-2
View Readings
View Conguraon
Advanced Sengs
Lock Advanced

10
MAIN MENU
View Readings
View Readings
This screen shows various readings and other informaon. See the list below for a descripon
of the readings.
This screen is useful for diagnosing installaon issues.
Title Descripon
Version: Firmware version number and hardware type
Serial No: Serial number of the unit
Input V: Supply input AC voltage
Grid V: Voltage of the supply connected to the
Wireless Sensor (where ed), otherwise
the same as Input V
Max Voltage: Maximum supply voltage recorded since
last switch on.
Min Voltage: Maximum supply voltage recorded since
last switch on.
Grid I: Current seen by the sensor clamp
Frequency: Supply frequency
Exporng/
Imporng: Power level currently being imported or
exported
Current: Input current of the unit
Output: Power being delivered to the load
P.W.M: Output voltage percentage
Heatsink: Temperature of the internal heatsink
Protects: Count of over-current protecons since
switch on
Sig Qual: Signal quality of immerLINK™
wireless connecon
Cal Date: Date the unit was calibrated at the factory
Reset: Date the unit was factory reset
Power O: Last date and me power was lost to the unit
Last Error: Last error number with date and me
VIEW READINGS
Version : 2.30.0/1
Serial No : 20546
Input V : 245V
Grid V : 0V
Max Voltage: 248V
Min Voltage : 232V
Grid I : -0.1A
Frequency : 50.0Hz
Exporng : 25W
Current : 8.9A
Output : 2108W
P.W.M. : 94%
Heatsink : 44oC
Protects : 0
Sig Qual : 91%
Cal Date : 20/10/2013
Reset : 16/02/2013
Power O : 20/10/2013
at : 16:36
Last Error : None
Table des matières
Manuels Routeur réseau populaires d'autres marques

NETGEAR
NETGEAR FS526T - Switch Manuel utilisateur

Korenix
Korenix JetNet 5710G Series Manuel utilisateur

Automated Logic
Automated Logic ZN551 Manuel du propriétaire

Cisco
Cisco ASR 1000 Series Manuel de l'opérateur

EnGenius
EnGenius ESR-9710 Manuel utilisateur

Cisco
Cisco 805 Series Instructions d'utilisation et de sécurité