Disclaimer
Warning Signs
• The vacuum pump is heavy. Be careful while handling to prevent personal injury.
• Use only ISO 46 mechanical oil to avoid vacuum pump damage.
• Do not cover the exhaust port during vacuum pump operation.
• Do not expose the suction port continuously to atmosphere for more than 3 minutes.
• The air inlet pressure should not exceed 27. 5 bar to avoid sensor damage.
-1-
Sign
Name
Content
Check the Oil
Level
Add ISO 46 mechanical oil
before the first use and keep the oil level
between the maximum and minimum level
Wear Goggles
Wear goggles when working with refrigerants
.
Direct contact with
refrigerants may cause injury
Beware of High
Temperature
Burns
The pump surface becomes hot during normal operation. Do not
touch the pump body or motor during operation
Avoid Electrical
Shock Hazards
Improper use may cause electrical shock hazards
Read and follow the instructions carefully and take precautions to
avoid electrical shock hazards . Confirm that all associated devices
are grounded correctly before power on
Danger
Please remove the exhaust cap before starting up
Check the oil level and prohibit running without oil

Product Features
Technical Parameters
• Intelligent Control of Motor and Solenoid Valve
• Leakage Level Judgment
• Vacuum Change in Graph
• 4" Touch Screen Display
• Estimated Job Completion Time
•Data Logging and Storage via App
-2-
Models
V700 V900 V1200
Stage
2 stages
Power Supply
110V/60Hz; 220V/50Hz
Motor
AC induction motor
Speed Regulation
Fixed speed
Vacuum Accuracy
1-10000microns ±10% of Reading / ±10microns
10000-19000 microns ±20% of Reading
Operating Temperature
41°F~104°F (5°C~40°C)
Transmission
Distance
30ft / 10m
Limit Vacuum
15 microns
Pumping Rate
7 CFM (3L/S) 9 CFM (4L/S) 12 CFM (5L/S)
Motor Power
3/4 HP ( 550 W ) 1 HP ( 750 W ) 1 HP ( 750 W )
Fuel Volume
22oz /(650ml) 22 oz /(650ml) 25.3 oz( 750ml)
Overall Dimension
18.5in×10.5in×14.8in / (470mm*267mm*380mm)
Weight
34.2lbs / 14.8kg 35.3lbs / 15.3kg 36.8lbs / 16kg
Air Inlet
1/4 SAE ;3/8 SAE

Service Parts
① Display screen
② Handle
③ Air inlet
④ Solenoid valve
⑤ Catcher
⑥ Oil tank
⑦ Base
⑧ Motor
⑨ Motor housing
⑩ Power button
⑪ Vacuum sensor
⑫ Oil window
⑬ Oil drain plug
-3-
1
9
8
7
6
5
2
43
12
13
10 11

Operation Guide
Interface Introduction
Conditions that must be met
1. Place on a flat surface.
2. Confirm the voltage and frequency at the outlet match with the vacuum pump
specifications.
3. Confirm the oil level is within the Min and Max level.
4.Remove the air inlet cap(1/4 SAE fitting as shown in the
right image), connect the pumped system(make sure the pipe
fitting is fit with the air inlet fitting). Tighten the air inlet and
make sure the system and hoses are sealed with no leakage.
5. Plug in the power cordand open the exhaust port.
-4-
1/4 SAE

-5-
(1) The status bar on top of the page shows the product model, time, Bluetooth status.
①Model numbers varies depending on the product models.
② Bluetooth not connect; Bluetooth connected.
③During operation, appear when temperature exceeds the upper alarm limit,
and appear when temperature below the lower alarm limit.
④Record: close means no data is recorded.Record Open: means that data is
being recorded.
(2) The middle part of the page is the sub-interface button.
① : Real-time measurement interface
② : Graph
③ : Vacuum parameter setting
④ : System parameter display and setting
(3) The motor is o by default after power-on. Click " " to start the motor. Click " "
to stop the motor.
When the motor starts, the solenoid valve automatically opens instantly. The solenoid
valve closes automatically after the motor stops to avoid the oil be suck to vacuum sensor.
1. Real time measurement interface
Click the“Measure” button on the main interface to enter the real-time measurement
interface.
Measure
Graph
Settings
System

(1) Motor Status: show the current status of the motor.
(2) Motor Temp/Limit: show the surface temperature of the pump chassis and set
the alarm temperature.
(3) Oil Temp/Limit: show vacuum pump oil temperature and set the alarm temperature.
(4) Vacuum Status: display the current vacuum value status, "Decrease", "Stable",
"Rise", "--".
(5) Estimated End Time: when the vacuum is stable, it shows the estimated job
completion time including holding time.
(6) Vacuum Reading Display: Vacuum readings shows when the vacuum of the
system in real-time is below 8000Pa. The waiting time for the vacuum reading
is longer for a larger system.
Note: The vacuum reading varies due to the sensor placement dierent. The reading
variances is caused by the uneven air flow during the vacuuming process. The farther
the air from the pump, the higher the air density is thus the vacuum reading is higher.
(7) Leakage level: when the vacuum is stable, check the leakage possibility from 0 to
100 levels. 0 represent uncertain leakage. The larger the number, the greater the
possibility of the leakage.
(8) Key: return to the main interface.
2. Graph
Click the “Graph” button on the main interface to view the vacuum change in real time.
(1) When the vacuum value drops below 8000 Pa, the vacuum change graph is displayed.
(2) The X axis represent time. Y axis represent vacuum. The vacuum value is from 0 Pa
to 8000 Pa.
(3) Key: return to the main interface.
-6-
STOP

3. Settings
Click the “Settings”button on the main menu to enter the setting interface.
Unit(P/T)
Select Unit to set the unit for vacuum and temperature. The selected units are in blue.
Vacuum
Set the minimum vacuum value, logging interval, and recording status.
(1) Minimum Vacuum: set the target vacuum value. The range of the minimum vacuum
value is 1Pa-100Pa. Click the change button to switch the minimum vacuum value;
the display unit changes according to the selected unit.
(2) Logging Interval (S):1, 5, 10, 30, 60, 120, 300.
(3) Recording Status: The logging can be turned on and o. The upper right corner
shows the logging/recording status.
-7-

Time
(1) Set and save the time then it shows at the top of the screen.
(2) : Change key.
(3) : return to the main interface.
-8-
4. System
In the main menu, click the “ System” button to enter the system interface.
(1) Running Time: refer to theaccumulatedrunning time of themotor.
(2) Holding Time: refer to the time for the vacuum pump to continue vacuuming
after the target vacuum value is stable.
(3) Flow Rate: refer to the pumping speed of the vacuum pump.
(4) : Change key.
(5) : return to the main interface.
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Elitech Pompe à eau
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur