Elitech SVP-7 Manuel utilisateur

IntelligentVacuumPump
UserManual
SVP-7/SVP-9/SVP-12
NEW

Contents
Disclaimer ···························································································1
Product Features ···············································································2
Technical Parameters ·········································································2
Service Parts ······················································································3
Operation Guide ···············································································4
Care and Maintenance ·······································································9
App Operating Instructions ······························································11

Disclaimer
WarningSigns
• Thevacuumpumpisheavy.Becareful while handling topreventpersonalinjury.
• Use only ISO 46 mechanical oil to avoid vacuum pump damage.
• Do not cover the exhaust port during vacuum pump operation.
• Donotexposethesuctionportcontinuouslytoatmosphereformorethan3 minutes.
• The air inlet pressure should not exceed 27. 5 bar to avoid sensor damage.
-1-
Sign
Name
Content
Checkthe Oil
Level Add ISO46 mechanical oil
beforethefirstuseandkeeptheoillevel
betweenthemaximumandminimumlevel
WearGoggles
Weargoggleswhenworkingwithrefrigerants
.
Directcontactwith
refrigerantsmaycauseinjury
Bewareof High
Temperature
Burns
Thepumpsurfacebecomeshotduringnormaloperation. Donot
touchthepumpbodyormotorduringoperation
Avoid Electrical
Shock Hazards
Improperusemay causeelectricalshockhazards
Readandfollowtheinstructionscarefullyandtakeprecautionsto
avoidelectricalshockhazards . Confirmthatallassociateddevices
aregroundedcorrectlybeforepoweron
Danger
Pleaseremovetheexhaustcap beforestartingup
Checktheoillevelandprohibitrunningwithoutoil

ProductFeatures
TechnicalParameters
• Intelligent Control of Motor and Solenoid Valve
• Leakage Level Judgment
• Vacuum Change in Graph
• 4" Touch Screen Display
• Estimated Job Completion Time
•Data Logging and Storage via App
-2-
Models
SVP-7 SVP-9 SVP-12
Stage
2 stages
PowerSupply
110V / 60HZ; 220V/50HZ
Motor
AC induction motor
SpeedRegulation
Fixed speed
VacuumAccuracy
1-10000microns ±10% of Reading / ±10microns
10000-19000 microns ±20% of Reading
OperatingTemperature
5°C~40°C(41°F~104°F)
Transmission
Distance
30ft / 10m
LimitVacuum
15 microns
PumpingRate
7 CFM (3L/S) 9 CFM (4L/S) 12 CFM (5L/S)
MotorPower
3/4 HP ( 550 W ) 1 HP ( 750 W ) 1 HP ( 750 W )
FuelVolume
22oz /(650ml) 22 oz /(650ml) 25.3 oz(750ml)
OverallDimension
18.5in×10.5in×14.8in / (470mm*267mm*380mm)
Weight
34.2lbs / 14.8kg 35.3lbs / 15.3kg 36.8lbs / 16kg
AirInlet
1/4 SAE ;3/8 SAE

ServiceParts
① Display screen
② Handle
③ Air inlet
④ Solenoid valve
⑤ Catcher
⑥ Oil tank
⑦ Base
⑧ Motor
⑨ Motor housing
⑩ Power button
⑪ Vacuum sensor
⑫ Oil window
⑬ Oil drain plug
-3-
1
9
8
7
6
5
2
43
12
13
10 11

OperationGuide
InterfaceIntroduction
Conditions that must be met
1. Place on a flat surface.
2. Confirm the voltage and frequency at the outlet match with the vacuum pump
specifications.
3. Confirm the oil level is within the Min and Max level.
4.Remove the air inlet cap(1/4 SAE fitting as shown in the
right image), connect the pumped system(make sure the pipe
fitting is fit with the air inlet fitting). Tighten the air inlet and
make sure the system and hoses are sealed with no leakage.
5. Plug in the power cordand open the exhaust port.
Maininterface
-4-
SVP-7 (110V)
Measure Graph Sengs System
16:22:34 Record: OFF
Start
1/4 SAE

(1) Thestatusbarontop ofthepageshowsthe product model,time,Bluetoothstatus
andrecordstatus.
①Model numbers varies depending on the product models.
② Bluetooth not connect; Bluetooth connected.
③During operation, appear when temperature exceeds the upper alarm limit,
and appear when temperature below the lower alarm limit.
④Record: close means no data is recorded.Record: Open means that data is
being recorded.
(2) The middle part of the page is the sub-interface button.
① : Real-time measurement interface
② : Graph
③ : Vacuum parameter setting
④ : System parameter display and setting
(3) Thebottompartisthe “Start” and“Stop”button. Themotoriso bydefaultafter
power-on. Click “Start” to start the motor. Button will be locked (within 3 sec);
Click “Stop” to stop the motor. Button will be locked (within 10 sec).
After the motor stops, in order to prevent frequent start and stop, the button is
invalid within 10 seconds.
When the motor starts, the solenoid valve automatically opens instantly. The
solenoidvalveclosesautomaticallyafter the motor stopstoavoidtheoilbesuck to
vacuum sensor.
1. Real time measurement interface
Clickthe“Measure”buttononthemaininterfacetoenterthereal-timemeasurement
interface.
-5-

(1) Motor Status: show the current status of the motor.
(2) Motor Temp/Limit: show the surface temperature of the pump chassis and set
the alarm temperature.
(3) OilTemp/Limit:show vacuumpumpoiltemperatureandsetthealarmtemperature.
(4) Vacuum Status: display the current vacuum value status, "Decrease", "Stable",
"Rise", "--".
(5) Estimated End Time: when the vacuum is stable, it shows the estimated job
completiontimeincludingholdingtime.
(6) Vacuum Reading Display: Vacuum readings shows when the vacuum of the
system in real-time is below 60000microns. The waiting time for the vacuum
reading is longer for a larger system.
Note: The vacuum reading varies due to the sensor placement dierent. The reading
variances is caused by the uneven air flow during the vacuuming process. The farther
the air from the pump, the higher the air density is thus the vacuum reading is higher.
(7)Leakagelevel: when the vacuum is stable, checktheleakage possibility from 0 to
100 levels. 0 represent uncertain leakage. The larger the number, the greater the
possibility of the leakage.
(8) Key: return to the main interface.
2. Graph
Clickthe“Graph”buttononthe maininterfaceto viewthevacuumchangeinrealtime.
(1) When the vacuum value drops below 60000microns, the vacuum change graph
is displayed.
(2) The X axis represent time. Y axis represent vacuum. The vacuum value is from
0-60000microns.
(3) Key:return tothemaininterface.
-6-
Return
Return

3. Settings
Click the “Settings”button on the main menu to enter the setting interface.
Unit(P/T)
SelectUnitto settheunitforvacuumand temperature.Theselectedunits areingreen.
Vacuum
Set the minimum vacuum value, logging interval, and recording status.
(1) MinimumVacuum:setthetargetvacuumvalue.Therangeof theminimumvacuum
valueis8-750microns.Clickthechangebuttontoswitchtheminimum vacuumvalue;
the display unit changes according to the selected unit.
(2) Logging Interval (S):1, 5, 10, 30, 60, 120, 300.
(3) Recording Status: The logging can be turned on and o. The upper right corner
shows the logging/recording status.
-7-

Time
(1) Set and save the time then it shows at the top of the screen.
(2) : Change key.
(3) : return to the main interface.
SVP-7 (110V) 16:22:34 Record: OFF
Return
Unit(P/t) Vacuum Time
M D Y
9 / 12 / 20 HMin
16 : 22
-8-
Return
SVP-7 (110V)
Running Time:
Holding Time:
Flow Rate:
3 Min
0 Min
7 CFM
16:22:34 Record: OFF
Return
4. System
In the main menu, click the “ System” button to enter the system interface.
(1) Running Time: refer to theaccumulatedrunning time of themotor.
(2) Holding Time: refer to the time for the vacuum pump to continue vacuuming
after the target vacuum value is stable.
(3) Flow Rate: refer to the pumping speed of the vacuum pump.
(4) : Change key.
(5) : return to the main interface.
Return
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Elitech Pompe à eau
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur