Ⓒelero GmbH EN | 98 | EN Ⓒelero GmbH
NOTICE
• Exchange components between dierent systems
only after consultation with the manufacturer or
your supplier.
• When replacing a component, check whether the
type description of the new component matches the
one being replaced.
2.5 Repairs
Damaged ExitSafe components may only be repaired
by the manufacturer. If necessary, contact your supplier.
2.6 Warranty
• The warranty period for ExitSafe is 12 months
from the date of purchase. Damages caused due
to improper use are excluded.
• Never open the device without authorisation. Opening
the housing renders the warranty null and void.
• No warranty claims may be made for damage caused
to the ExitSafe due to improper operation resulting
from non-observance of the operating instructions or
due to a disregard of these instructions.
• There is no liability for consequential damages.
3 System description
3.1 Application area
ExitSafe enables mains-buered operation for electrically
powered roller shutters, venetian blinds and rolling doors.
ExitSafe may be used if the function of one tubular motor
has not yet been enabled, even in the event of a failure in
the 230 V mains supply of a building.
3.2 General overview of functions
The ExitSafe receives the commands UP and DOWN/
CLOSE from a local operator position (individual control)
or from the building automation (master control) via
potential-free contacts at the inputs. ExitSafe controls
the connected DC drive with the corresponding sense
of rotation accordingly. The drive is powered by the
ExitSafe battery pack. The battery pack is then slowly
recharged via the mains supply.
The ExitSafe monitors the charging status of the battery
pack. If the charging status has fallen to the point that
only one complete UP movement of the drive can be
guaranteed, then a warning signal will sound. For this
case, the ExitSafe can be set to allow automatic control
of the drive.
The performance of the ExitSafe battery pack decreases
over time. For this reason, the battery pack should be
replaced after two years or 500 charging cycles.
A warning signal can be set in ExitSafe to sound
when that this time period has been reached.