The sensor coating is highly durable against chemical
substances and mechanical damages, e.g. dust.
The sensor surface is resistant against the following
chemicals: detergents (soap, Armor All (plastic
cleaner/preservative), Formula 409, etc.), Food &
Beverages (Cola, coffee, juice, etc.), alcohol, oil, grease,
petrol, brake fluid, etc., hand lotion.
Generally speaking, the finger scanner does not require any
maintenance.
The only exception is visible dirt on the sensor.
If this is the case, please clean the sensor area.
Recommendation: lean the finger scanner using a wet,
soft and not scratching rag.
Mounting Bracket
Sealing Flanch
(only for outdoor operation)
b) Before you start with the actual installation, hold on tight the finger scanner, inserts, spacer and
design frame, and the mounting bracket to check how to position the mounting bracket to level
the scanner with the design frame.
c) Tighten the mounting bracket
(1)
on the gang box
(2)
either in position A or position B.
A or B results from the installed position of the bracket
( ).
Position A: short distance | Position
B: large distance (i.e. distance between bezel and mounting bracket)
(4)
. For fine-tuning the final
position, please use one or more inserts.
IP33/43 is realized via spacers and design frames from different the producer of electric switches.
Using the frame supplied by ekey, you can reach IP44
(5)
.
d) Once you have decided on the final position, place the cable as shown in the drawing above and
tighten the finger scanner
(6)
using 2 screws to the mounting bracket.
e) Finally, clip the bezel
(7)
onto the finger scanner.
a) Use a gang box according to DIN49072.
Pay attention to the specified installation
height of either 155 cm or 100 cm from
ground level.
The gang box has to stick to the minimum
dimensions as outlined in the drawing above
(DIN49072).
The recommended installation height is
155 cm
from ground level to the lower
edge of the scanner (or higher)!
To safeguard proper operation by the user,
resulting in an acceptable rate of
recognition, pay attention to the specified
installation height!
Alternatively, you can also install the finger
scanner horizontally. The recommended
installation height is
110 cm
then!
Make sure to have enough space on both
sides of the finger scanner to allow proper
operation with all fingers.
Installation Height
Installation
a) ut out an area of W 39,5 mm H 85 mm D 6 mm in the door panel or door frame
(1).
b) Use the supplied screws (2 . 2,9 19 / 2 2,9 38) for mounting the finger scanner
(2)
. Attention! Do not tighten screws too much; otherwise the housing might
get damaged! By tightening the screws, the 3 clamps
( )
will move outwards securing the finger scanner.
c) Finally, clip the design element
(4)
onto the finger scanner.
For the installation into a solid wall you will require a mounting bracket. Please contact your ekey installer for further details!
Make sure to have enough space on both
sides of the finger scanner to allow proper
operation with all fingers.
The recommended installation height is
155 cm
from ground level to the lower
edge of the scanner (or higher)!
To safeguard proper operation by the user,
resulting in an acceptable rate of
recognition, pay attention to the specified
installation height!
Installation Height
Installation
design frame with all frames from different producers.
In this case, the ekey FS OM will stick out
on the front side.
The recommended installation height is
1 5 cm
from ground level to the lower
edge of the scanner (or higher)!
To safeguard proper operation by the user,
resulting in an acceptable rate of
recognition, pay attention to the specified
installation height!
sides of the finger scanner to allow proper
operation with all fingers.
a) To mount the ekey FS WM 2.0
(1)
, please use the supplied screws and plastic dowels.
(2)
Mark the drill holes on the wall
using the mounting bracket
( )
.
b) Drill two 5 mm wide holes and place the dowels into them. Afterwards, fasten the mounting bracket using the corresponding screws.
To establish the electrical connection, please refer to the wiring plan.
c) Finally, clip the ekey FS WM 2.0 into the mounting bracket and fix the scanner tightening the dedicated screw
(4)
.
Installation Height
integra (IN)
Outlet mounted (OM)
The sensor must not be touched using
object as it could destroy the sensor!!
Cleaning & Maintenance
This installation manual as well ast he information provided on the accompanying DVD is not subject to any
The latest valid version of this document is available under
Subject to optical and technical modifications, any liability for misprints excluded!
Installation
for ekey Finger Scanner (FS)
Description Unit Value
Power Supply VA 8-24
VD 8-24
Power Input W ca. 1
Temperature Range ° -25 up to +75
Memory Size Fingerprints home: 99
net: 40/200/2000
Security FAR 1x 10
IP class IP 44
Matching Speed S 1-4
Life Span Swipes ca. 10 Mio
Dimensions mm B: 45 H: 81,6 T: 60,
Technical Data
Spacer and
Design Frame
Insert
Finger Scanner
Gang Box according to
DIN49072 for installation in
walls
Dimension Gang Box
Description Unit Value
Power Supply VA 8-24
VD 8-24
Power Input W ca. 1
Temperature Range ° -25 up to +70
Memory Size Fingerprints home: 99
net: 40/200/2000
Security FAR 1x 10
IP IP33/44 depending on
frames
Matching Speed S 1-4
Life Span Swipes ca.10 Mio
Dimensions mm B: 50,4 H: 50,4 T: 0,1
Technical Data
The LED indicates a dirty sensor by blinking red-green
Description Unit Value
Power Supply VA 8-24
VD 8-24 (max. 30V)
Power Input W ca. 1
Temperature Range ° -25 up to +70
Memory Size Fingerprints home: 99
net: 40/200/2000
Security FAR 1x 10
IP class IP 54 (front end)
Matching Speed S 1-4
Life Span Swipes ca. 10 Mio.
Dimensions mm W: 4 ,6 H: 89 D: 17,
Technical Data
Opening for cable feed (RJ45)
Fixing Screw
Finger Scanner
Screw
Mounting Bracket
Finger Scanner
Screw Driver