Operating / Safety Instructions
Consignes de fonctionnement / sécurité
Instrucciones de funcionamiento y seguridad
model SKT05
SKT05L
IMPORTANTE:
Leer antes de usar
IMPORTANT
Lire avant usage
IMPORTANT:
Read Before Using

2
GENERAL SAFETY RULES
Working safely with this instrument is possible only when the operating and safety infor-
mation are read completely and the instructions contained therein are strictly followed.
The use of controls, adjustments, or the performance of procedures other than those
specied herein may result in hazardous radiation exposure.
DO NOT aim the telescopic tube at the sun directly,which will do harm to eyes.
DO NOT carry the instrument while attached to tripod.
DO NOT place the instrument in the sun for a long periods of time.
DO NOT disassemble the instrument or attempt to perform any internal servicing.
Laser class is indicated on the instrument. Repair and servicing of this laser are to be
performed only by SitePro or authorized service centers.
• When attaching the instrument to a tripod, make sure the instrument is securely
xed. The tripod leg clamps should be securely fastened. If not securely fastened
or tightened, the main unit could fall off or the tripod could fall over.
• The instrument should not be stored or used in extreme temperature or during
rapid temperature change.
• Store inside the carry case and place in a dry area not subject to vibration, dust
or high moisture. If the storage temperature and ambient temperature for usage
vary signicantly, leave the laser in its case until it can adjust to the ambient
temperature.
• The instrument should be transported or carried carefully to avoid impact or
vibration.
• The instrument should be stored in the carry case and packed with cushioning
material. Always handle the instrument with care.

www.SitePro.us.com 3
1
9
10
8
5
6
7
3
2
4
11
SKT05 Only
FEATURES
1. Handle
2. Objective Lens
3. Collimator
4. Vertical Adjustment Knob
5. Horizontal Adjustment Knob
6. Focus Knob
7. Eyepiece Lens
8. Battery Compartment
9. Display
10. Instrument Leveling Screws
11. Optical Plummet (SKT05)

4
Display Icon Description
%Vertical angle gradient percentage
Angle unit (GON)
Battery capacity
Slope distance
Horizontal distance
Height difference
Distance unit (meter)
distance unit(foot)
DISPLAY SYMBOLS AND KEY FUNCTIONS

www.SitePro.us.com 5
Key Primary Function Other Function
ON
1. Start to initial setting of
instrument
2. Start to index error set-
ting of instrument
3.Start to compensator set-
ting of instrument
Reticle, board illumination, for SKT05L: laser down
centering start-up button
and OFF
Horizontal angle
Return to zero
1. Start to initial setting of
instrument
2. Start to index error set-
ting of instrument
3. Start to compensator
setting of instrument
Horizontal right and left
angle choosing/gradient
choosing
1. Start to initial setting of
instrument
2. Start to compensator
setting of instrument
Horizontal angle memory
button
1.Start to initial setting of
instrument
2.Start to compensator
setting of instrument

6
INITIAL SETTING
The instrument has many functions. In order to be appropriate to different observation,
please do initial setting before observation.
SETTING ITEMS
Unit of angle setting: °(degree) ‘ (cent) “(second)
(360 degrees one circle)
GON (400G one circle)
mil (6400mil one circle)
Factory setting ° ‘ “
Vertical angle “0” way setting:
horizontal: 0 degree (zenith distance :90 degree)
zenith distance: 0 degree (horizontal: 90 degree)
factory setting: zenith distance: 0 degree
Power auto off function: 30 min or deactivate
Factory setting: 30 mins
Minimum unit of angle displayed: 1” or 5”
Factory setting: 1”
Vertical index zero compensation setting:
Auto compensation or uncompensated
Factory setting: Auto compensation
Horizontal angle reading passes through 0°, 90°m, 180°, 270°, with audible ON
or OFF
Factory setting: No beeps

www.SitePro.us.com 7
SETTING METHOD
Press key to turn power on and hold it until all the symbols displayed,then loose the
key. After three beeps, loose the key. The instrument will be into initial setting
mode.
Press key to move the cursor to the next gure.
Press key to change the gure.
When all the initial setting is nished, press [0SET] key to come back to measurement
mode.
Steps as follows:
1. Press key to turn power on,entering into initial setting status.
2. Buzzer prompt of horizontal angle position:
• ‘NO BEEP’ - no buzzer prompt in horizontal angle, Press key
and for choosing
• ‘90 BEEP’ - the horizontal angle is close to 0°, 90°, 180°,
270°, buzzer sound.
3. Unit of angle, Press key and for page turning.
• ‘UNITA’ 360°
• ‘UNITB’ 400G
• ‘UNITC’ 6400mil
4. Vertical angle “0” position, Press key and for page turning.
• ‘ZEN=0’ zenith angle is 0°
• ‘ZEN=90’ zenith angle is 90°
5. Auto power off time, Press key and for page turning.
• ‘NO OFF’ non auto power off
• ‘30 OFF’ auto power off after 30 mins without any pressing

8
6. Minimum unit of angle displayed, Press key and key for page turning.
• ‘DSP 1’ mini display 1”
• ‘DSP 5’ mini display 5”
7. Vertical compensator setting, Press key and key for page turning.
• ‘VTILT ON’ turn on compensator
• ‘VTILT OFF’ turn off compensator
8 . When the initial setting is nished, the key must be pressed to conrm and save
the setting. Otherwise, the setting will be the former setting before.
PREPARATION FOR SURVEYING
BATTERY
This series electrical theodolite adopt rechargeable lithium battery, The battery is
3.7v,1400mAh.
Insert and remove battery
Turn off power,press the top button of battery box and then remove battery.Insert the
battery box into the groove and then press the top button of battery.
Battery message
Fully recharged new battery can be used 15 to 20 hours continuously. Right down
message display consumption message. Each segment indicates about four hour’s
consumption energy.
• and indicate that battery level is abundant.
• indicates that the battery can be used only about two hours. Recharge the battery
or replace with a recharged battery.
• When ickers then disappears indicates the battery level is low and. The
instrument only can be used approximately 20 minutes. Stop operating and change
the battery as soon as possible.

www.SitePro.us.com 9
Battery recharging
• Battery should be recharged with the special charger. Insert the battery charger
into the power source with 220V or 110V, remove the on-board battery from the
main body, and connect the plug of the charger to the charging connector on the
battery. The indicating red lamp is on that indicates the battery is been recharging
and recharge will be completed after green lamp indicated. Then remove the plug
from the charging connector.
SETUP INSTRUMENT
• Adjust the tripod legs to obtain a suitable height.
• Make sure the surveyed point is under the centering hole of tripod head.
• Level the tripod head and lock.
• Put the instrument on the tripod head and lock with the screws.
LEVELING
Level the instrument with circular vial
• Turn B and C to let the bubble move to centre line.
• Turn knob A to let bubble stay at center of circular vial.
Level the instrument with plate vial
• Loose level clamping knob and turn knob B and C
to let bubble center.
• Rotate the instrument 90°and then turn knob A
to let bubble center
• Repeat above steps in each 90 degrees
rotating,and check if bubble have been centered
CENTERING THE INSTRUMENT
Turn on laser plummet, and make sure the laser
land mark can been seen clearly, make sure that
the land mark coincides with the center of the
reticule,then lock the instrument. Repeat above
steps and make sure the land mark denitely
coincides with the center of the reticule.

10
POWER ON INSTRUMENT
To turn power ON, Press red key and hold it until all the symbols are displayed. The
power is on.
SIGHT TARGET
Turn telescope to bright background,turn eyepiece knob until reticle can been seen
clearly.
• Use coarse sighting device to sight target.
• Rotate vertical and horizontal brake knob and focus knob of telescope until target
can be seen clearly.
• Rotate vertical and horizontal ne knob until center of reticle precisely aim at
target.
• Eliminate parallax. View the target in up and down,left and right position through
scope. If there is relative displacement between target and both cross line images,
rotate telescope focus knob until both images relative rest and can be seen clearly.
ANGLE MEASUREMENT
NORMAL/REVERSED POSITION TELESCOPE
“Normal position telescope” means that the shaft disc is on the left side of the telescope
when observers face eyepiece lens. “Reversed position telescope” means that the shaft
disc is on the right side of the telescope when observers face eyepiece lens.
Averaging the value of normal/reversed position can effectively eliminate the instrument
systematic errors. So when measure angle,please rotate telescope 180° and observe
with reversed position telescope after observing with normal position telescope.
HORIZONTAL ANGLE “0” SETTING
Sight the telescope at object A, press , set the horizontal angle reading as
0°00’00”.
Note: The key is valid only for horizontal angle. Horizontal angle can be set to 0 at
any time except when key is locked.