Dux Ecosmart 250DPM36 Manuel utilisateur

Electric Boosted Models:
Gas Boosted Models:
Specications and materials may change without notice.
Effective for the above models of Dux Solar Water Heaters manufactured and sold after 1st November 2018.
Owner’s Manual
250DPM36 | 315DPM36 | 400DPM36
250DP0 | 315DP0 | 400DP0
H3165 029664 Rev. B
For advice, repairs and service, call:
1300 365 115 (Australia)
0800 729 389 (New Zealand)
Carefully remove all packaging and
transit protection from the water heater
before installation. Dispose of the
packaging responsibly using re-cycling
facilities where they exist.
Installation Details
Owner’s Information
Warranty
Solar Water Heaters With Electric Or Gas Boosting

Owner’s Manual – Solar Water Heaters
H3165 029664 Rev. B
Important Safety Information
WARNING – THIS APPLIANCE
MAY DELIVER WATER AT HIGH
TEMPERATURE. REFER TO THE
PLUMBING CODE OF AUSTRALIA
(PCA), LOCAL REQUIREMENTS
AND INSTALLATION INSTRUCTIONS
TO DETERMINE IF ADDITIONAL
DELIVERY TEMPERATURE CONTROL
IS REQUIRED.
WARNING – FOR CONTINUED
SAFETY OF THIS APPLIANCE IT
MUST BE INSTALLED, OPERATED
AND MAINTAINED IN ACCORDANCE
WITH THE MANUFACTURER’S
INSTRUCTIONS.
General:
This water heater is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision
or instruction concerning use of the water
heater by a person responsible for their
safety.
Children should be supervised to ensure they
do not play with the water heater.
Animals should be supervised to ensure they
do not interfere with the water heater.
DO NOT store chemicals or ammable
materials, or spray aerosols near this water
heater.
DO NOT modify this water heater.
DO NOT operate the water heater with any
panels or covers removed.
Installation Precautions:
The water heater is intended to be
installed by properly trained and licensed
tradespersons.
The installer should carry out a risk
assessment prior to the installation of the
water heater. The risk assessment should
consider at least the hazards associated
with:
• Heavy components.
• Work at heights.
• Electricity
• Gas
• Water under pressure.
User Maintenance Precautions:
Stand clear of the relief valve discharge pipe
outlet when lifting the easing lever on the
valve.
Stand clear of the solar collector drain pipe
when purging or draining the solar collectors.
Do not attempt to clean the solar collectors
unless they can be safely accessed.
Draining the Water Heater:
The method of draining the storage tank and
the solar collectors is described on pages 20
and 21.
i

Owner’s Manual – Solar Water Heaters
H3165 029664 Rev. B
Important Safety Information
Relief Valve:
The Pressure & Temperature Relief (PTR)
Valve must be installed directly into the
RP½”(DN15) socket marked “RELIEF
VALVE”.
The PTR Valve rating is 1,000 kPa and is
also shown on the compliance plate.
The valve must not be tampered with or
removed. The water heater must not be
operated unless this valve is tted and in
working order.
The PTR Valve should be checked by
a licensed tradesperson for adequate
performance, or replaced at intervals not
exceeding ve years, or less in areas where
local regulations apply.
The PTR Valve is to be operated regularly to
remove lime deposits and to verify it is not
blocked.
DANGER – FAILURE TO OPERATE
THE PTR VALVE EASING LEVER AT
LEAST ONCE EVERY SIX MONTHS
MAY RESULT IN THE WATER HEATER
EXPLODING.
Continuous leakage of water from the PTR
Valve may indicate a problem with the water
heater. This may be caused by excessive
water supply pressure, a faulty PTR Valve or
a faulty thermostat.Turn off the water heater
and contact Dux After Sales and Service.
Relief Valve Discharge Pipe:
The discharge pipe connected to the PTR
Valve is to be installed in a continuously
downward direction and in a frost-free
environment.
It is normal for water to drip from the
discharge pipe of the PTR Valve during
heating cycles. The discharge pipe must be
left open to be atmosphere.
Permanent Water Connection:
The water heater is intended to be
permanently connected to the water supply
main, and not connected by a hose-set.
Water Supply Pressure:
This water heater is designed for direct
connection to water supply pressures of up
to 800 kPa.
Where the mains pressure can exceed or
uctuate beyond this pressure, a pressure
reducing valve must be tted in the cold
water inlet supply.
Temperature Protection:
Water heaters can produce very hot water.
To reduce the risk of scald injury, it is
mandatory that an approved temperature
control device (such as a tempering valve)
is tted to the hot water supply to outlets
used primarily for the purposes of personal
hygiene. This device should be checked at
regular intervals to ensure its operation and
settings remain correct.
ii

Owner’s Manual – Solar Water Heaters
H3165 029664 Rev. B
Electrical Safety:
This water heater is designed for single
phase 240V a.c. supply only. The electrical
connection must comply with Local Supply
Authority Regulations and AS/NZS 3000.
Any electrical covers including the solar
module cover, should be removed only by
a licensed tradesperson, and only after the
electrical supply to the water heater has
been isolated.
In addition to the PTR Valve and the Solar
Controller, electric boosted models are tted
with a combination thermostat and over-
temperature energy cut-out.
These devices must not be tampered with
or removed. Replacement of these devices
must only be carried out by a licensed
tradesperson or the manufacturer.
The water heater must not be operated
unless these devices are tted and in
working order.
Electric Booster Connection:
The electric booster is to be connected
to the power supply using xed wiring.
A means for disconnection must be
incorporated in the xed wiring in
accordance with the Wiring Rules.
When the supply wiring has been
connected, ensure the wires are kept
away from the inner tank, thermostats
and heating elements.
The thermostat controlling the electric
booster is pre-set to 60°C and should not
be adjusted.
Gas Booster Temperature Setting:
The instantaneous gas water heater must
be set to 75°C as described on page 19. A
remote controller must not be connected to
the water heater.
Solar Controller Installation and
Setting:
The solar collector temperature sensor is to
be connected to the terminal block located
under the solar module cover as described
on page 11.
The temperature settings of the solar
controller are pre-set and are not user
adjustable.
Solar Controller Supply Cord:
If the solar controller supply cord is
damaged, it must be replaced by the
manufacturer, its service agent or similarly
qualied persons in order to avoid a hazard.
Not Using Hot Water?
If the water heater is not used for two weeks
or more, a quantity of hydrogen (which is
highly ammable) may accumulate inside the
water heater tank.
The procedure to dissipate this gas is
described on page 25.
Power Failure or Disconnection:
WARNING: Do not turn off the power
supply to the solar controller. The solar
controller is designed to be continuously
powered.
The procedure to disconnect is on page 25.
Important Safety Information
iii

Owner’s Manual – Solar Water Heaters
H3165 029664 Rev. B
INSTALLATION REQUIREMENTS
General:
The water heater must be installed by a
licensed tradesperson, and in accordance
with:
• In Australia, the Plumbing Code of
Australia (PCA);
• Clause G12 of the NZ Building Code (in
New Zealand).
• AS/NZS 3000 Electrical Installations
(known as the Australian / New Zealand
Wiring Rules).
• AS/NZS 5601.1 Gas Installations –
General Installations (for Gas Boosted
Models).
• Local authority regulations.
• Outside Australia and New Zealand,
please refer to local plumbing and building
codes and regulations.
Failure to comply with these requirements
will affect the warranty.
AS/NZS 3500.4 Plumbing and Drainage –
Heated Water Services provides a Deemed-
to-Satisfy solution for the PCA and a
Verication Method for Clause G12 of the
NZBC. Other methods of compliance are
available. Dux recommends that installations
conform with AS/NZS 3500.4."
Note for Victoria:
The water heater must be installed by a
licensed person as required by the Victorian
Building Act (1993).
Only a licensed person will provide a
compliance certicate, showing that
the work complies with all the relevant
Standards. Only a licensed person will have
insurance protecting their workmanship.
Water Heating System:
This solar water heater is designed and
certied to be installed as part of a water
heating system.
Please read this manual in conjunction with
the manuals for the:
• Solar Collectors.
• Tempering Valve.
• Instantaneous Gas Water Heater
(for Gas Boosted Models).
Frost-Prone Areas:
This solar water heating system may not
be suitable for installation in all frost-prone
areas. Installations in regions identied by
Dux as unsuitable will affect the system's
warranty.
Please consult www.dux.com.au/installation-
areas or Dux After Sales and Service for
further information.
Pool Heating:
The water heater must not be used for pool
heating.
Circulated Hot Water Systems:
This water heater is not designed to be
installed as part of a circulated hot water
ow and return system.
If a circulated ow and return system is
required, please consult Dux After Sales and
Service for advice.
Important Safety Information
iv

Owner’s Manual – Solar Water Heaters
1H3165 029664 Rev. B
© Dux Manufacturing Limited 2020. All rights reserved.
This page is intentionally blank

Owner’s Manual – Solar Water Heaters
2H3165 029664 Rev. B
Contents
Important Safety Information i
Installation Requirements iv
Introduction 3
Specications 4
Location 5
Water Supply 6
Solar Collector Pipework 7
Solar Module Cover 10
Solar Controller Connection 11
Cold Water Connections 12
Hot Water Connections – Electric Boosted Models 13
Hot Water Connections – Gas Boosted Models 15
Relief Valve 17
Electric Booster Connection 18
Gas Booster Installation 19
Fill, Flush and Drain – Storage Tank 20
Fill, Flush and Drain – Solar Collectors 21
Commissioning 22
System Maintenance 23
Non-Continuous Operation 25
Considering a Service Call? 26
Warranty 28

Owner’s Manual – Solar Water Heaters
3H3165 029664 Rev. B
Introduction
General:
This Owner’s Manual applies to the Dux
Ecosmart range of Electric and Gas Boosted
Solar Water Heaters.
Electric Boosted Solar Water Heaters:
Solar water heaters heat water by pumping it
through the solar collectors when conditions
are suitable.
During the winter months or when it is
cloudy, there may not be enough solar
energy gain available to heat the required
quantity of water. An electric element is
installed in the storage tank of the water
heater to boost the water temperature as
required. The electric element is controlled by
a separate thermostat.
The plumbing and electrical connections to
the solar collectors are the same for both
electric and gas boosted models. The hot
water plumbing connection and the electrical
connection to the boost element are specic
to the electric boosted models.
Throughout this manual, most pages are
common to both electric and gas boosted
models while some pages are specic to
electric boosted models. Those pages that
are specic to electric boosted models are
clearly identied.
Electric Boosted Solar Water Heater Models
are:
• 250DPM36
• 315DPM36
• 400DPM36
Gas Boosted Solar Water Heaters:
Solar water heaters heat water by pumping it
through the solar collectors when conditions
are suitable.
During the winter months or when it is
cloudy, there may not be enough solar
energy gain available to heat the required
quantity of water. An instantaneous gas
water heater is installed between the storage
tank of the water heater and the hot water
outlets to boost the water temperature as
required. The instantaneous gas water heater
is controlled separately.
The plumbing and electrical connections to
the solar collectors are the same for both gas
and electric boosted models. The hot water
plumbing connection and the gas connection
to the instantaneous water heater are specic
to the gas boosted models.
Throughout this manual, most pages are
common to both gas and electric boosted
models while some pages are specic to
gas boosted models. Those pages that are
specic to gas boosted models are clearly
identied.
Gas Boosted Solar Water Heater Models are:
• 250DP0
• 315DP0
• 400DP0

Owner’s Manual – Solar Water Heaters
4H3165 029664 Rev. B
Specifications
Nominal Dimensions 250L 315L 400L
A – Overall Height (mm) 1440 1760 1700
B – Overall Diameter (mm) 730 730 820
C – Outlet Height (mm) 1210 1530 1445
D – Solar Return Height (mm) 640 845 645
E – Pump Outlet Height (mm) 520 520 545
F – Inlet Height (mm) 195 195 220
G – Electrical Entry Height (mm)
(Electric Boosted Models Only) 680 880 695

Owner’s Manual – Solar Water Heaters
5H3165 029664 Rev. B
Location
General:
Solar water heater storage tanks are
normally installed outdoors. The storage tank
should be located as close as possible to
the most frequently used hot water outlet.
Consideration should be given to the route
taken by solar collector piping and drain
lines.
Ensure the compliance plate and associated
warnings are clearly visible.
The storage tank must be accessible without
the use of a ladder or scaffold. Adequate
clearance must be available for service to the
solar controller, circulation pump, relief valve,
sacricial anode, and the electrical cover of
electric boosted models.
Indoor Installation:
Solar water heater storage tanks may be
installed indoors. A properly drained safe tray
must be installed where property damage
could occur from water spillage. Refer to
AS/NZS 3500.4 for further information.
Note - the warranty will not cover damage
due to leakage of the water heater if a
properly drained safe tray has not been
installed.
Refer to local regulations before installing the
storage tank in a roof space.
Water Heater Support:
The water heater storage tank must be
installed on a at, solid supporting surface.
The pipework must not be used to support
the water heater. The installation of the
storage tank must not compromise the
structural integrity of the building.
Where the storage tank is subjected to wet
conditions, a plinth should be installed under
the storage tank.
Gas Boosted Models:
The instantaneous gas water heater must be
installed outdoors. It must also be located
to ensure that the connection pipe to the
storage tank is no more than 2 metres in
length.
The location of the ue terminal must comply
with the requirements of AS/NZS 5601.1
or local rules and regulations. Refer to the
instantaneous gas water heater Installation
Manual for further information.
Solar Collectors:
For maximum solar gain, solar collectors
should face no greater than 45° east or west
of true north.
Please refer to AS/NZS 3500.4 for further
information relating to solar collector
positioning.
Ce manuel convient aux modèles suivants
5
Table des matières
Manuels Système d'eau populaires d'autres marques

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuel utilisateur

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuel utilisateur

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuel utilisateur

Microline
Microline T.F.C.-4 Manuel

Eureka Forbes
Eureka Forbes Aquaguard Select Manuel utilisateur

Cetetherm
Cetetherm AquaEfficiency Manuel utilisateur











