Dräger Polytron 5000 Manuel utilisateur

Docking Station for Ex e version of
Polytron® 5000/8000
Assembly instructions
enUS · de · fr · es · bg · cs · da · el · et · fi · hr · hu · it · lt · lv · nl · no · pl · ptBR · ro · ru · sk · sl · sv · tr · zh

enUS Assembly instructions.............................................................8
de Montageanweisung...............................................................13
fr Notice de montage................................................................18
es Instrucciones de montaje......................................................23
bg Инструкция за монтаж ........................................................28
cs Montážní návod ....................................................................33
da Monteringsvejledning............................................................38
el Οδηγίες τοποθέτησης ...........................................................43
et Paigaldusjuhend ...................................................................48
fi Asennusohje .........................................................................53
hr Uputa za montažu.................................................................58
hu Összeszerelési útmutató ......................................................63
it Istruzioni di montaggio..........................................................68
lt Montavimo instrukcija ...........................................................73
lv Montāžas instrukcija .............................................................78
nl Montage-instructie ................................................................83
no Monteringsanvisning.............................................................88
pl Instrukcja montażu................................................................93
ptBR Instruções de montagem ......................................................98
ro Instrucţiuni de montaj..........................................................103
ru Инструкция по сборке.......................................................108
sk Návod na montáž................................................................113
sl Navodila za sestavljanje .....................................................118
sv Monteringsanvisning...........................................................123
tr Montaj ve kurulum kılavuzu ................................................127
zh 安装说明 .............................................................................132
Docking Station for Ex e version of Polytron® 5000/8000

36808
A2
1
2
3
red (+)
black (-)
brown (4-20mA)
(4-20mA)
-
+
12 3
1 2 3
~12 mm
~45 mm
ab
cd
AA1
B C
Without relay:

36809
PWR+
PWR-
PWR-
4-20 mA
PE
VDC
+
-
mA
4-20 mA / HART (Current source)
Analog, relay
PWR+
PWR-
PWR-
4-20 mA
PE
Stand-alone, relay only
VDC
+
-
4-20 mA / HART (Current sink)
PWR+
PWR-
PWR-
4-20 mA
PE
VDC
+
-
4-20 mA / HART (separate power supply)
mA
PWR+
PWR-
PWR-
4-20 mA
PE
VDC
+
-
mA
D4
D3
D2
Common
Normally Open
PE
4-20 mA
PWR-
PWR-
PWR+
D1
D2
D3
D4
A1
A2
FAULT
PE
D
D1

36810
PWR+
PWR-
SCR
Digital: Fieldbus FF / Profibus PA, Modbus RTU
Power
VDC
+
-
FIELDBUS (X2)
PWR+
PWR-
SCR
E1
FB+
FB-
COM
SCR
E2
E3
E2 Fieldbus FF / Profibus PA
E3 Modbus RTU
FB +
FB -
COM
SCR
FB +
FB -
COM
SCR
FB+ / Data A
FB- / Data B
+ / Data A
- / Data B
Ground
E
E1

36896
S1 / PE
S2 / 5
S3 / 4
S4 / 2
S5 / 1
F2
F F2
PIR 7x00
F1
Field wiring
PIR 7x00 + Docking Station
C1
C1
S1S1
S2S2
S3S3
S4S4
S5S5
PE YellowPE Yellow
5 White5 White
4 Brown4 Brown
2 Black2 Black
1 Red1 Red
S1 S3 S5S1 S3 S5
S2 S4S2 S4
7
POWER FAULT
7
POWER FAULT
44 5533
22
11 PEPE
RR BLKBLK BRBR WW YY

36807
GG2
DD, DQ, LC
DSIR
G1
3 - core field wiring
(Sensors: DSIR, DD, DQ, LC)
5 - core field wiring
(Sensors: DSIR, DD, DQ, LC)
Ferrit (Sensors: DD, DQ, LC)
C1
C2
2
1
1
G4
C1
G3
C1
S2 S4S2 S4
S1 S3 S5S1 S3 S5
S2 S4S2 S4
S1 S3 S5S1 S3 S5
3
2
1
3
2
1
BLKBLK
Y
BRBR
BLKBLK
Y
BRBR
G4G4

8 Assembly instructions | Docking Station for Ex e version of Polytron® 5000/8000
en | Safety information
Docking Station for Ex e version of Polytron® 5000/8000
1 Safety information
Any use of the Docking Station for the e-version of Polytron1) 5xx0/8xx0
requires full understanding and strict observance of the instructions for use of
the respective Dräger Polytron instrument (e. g. Dräger Polytron 5000/8000
instructions for use).
2 Conventions in this document
2.1 Meaning of the warning notes
The following warning signs are used in this document to indicate and highlight
areas of the associated text that require particular attention by the user. A
definition of the meaning of each sign is as follows:
3 Functional description
The Docking Station is required for the electrical installation in any area with an
"increased safety" explosion protection rating.
● Instrument for increased safety (Ex e)
The instrument is extended by an increased safety terminal box (docking
station) that provides up to four 20 mm openings, which can be used for field
wiring or wiring of a remote sensor. The permissible cable diameter range is
7 to 12 mm.
The Docking Station can be pre-mounted, wired and sealed with the supplied
cover. Once the site is ready for commissioning, the instrument is then hooked
up to the Docking Station and taken into operation; avoiding that the instrument
is damaged during the construction phase.
The connection between the Docking Station and the main instrument is
realized via a ‘feedthrough’. Depending on the instrument selected, there are 3
types of feed-through.
– feedthrough 3 wires for power
– feedthrough 9 wires for power and relay
– feedthrough 14 wires for power, interface connections or relay and remote
sensor (not for Polytron® 8100 EC)
4 Intended use
The Docking Station is intended for installation either in hazardous areas of
zone 1, 2 or 21, 22 according to device categories 2G, 3G or 2D, 3D.
The Docking Station is suitable for wall, ceiling and duct mounting.
Duct mounting requires additional mounting kits.
5 Assembly
The gas detector can be used to measure gases in the ambient air or in a
pipe/duct.
1. Attach the Docking Station to one of the following options.
1) Polytron® is a registered trademark of Dräger.
Alert icon Signal word Consequences in case of nonob-
servance
WARNING Indicates a potentially hazardous situa-
tion. If not avoided, it could result in
death or serious injury.
CAUTION Indicates a potentially hazardous situa-
tion. If not avoided, it could result in
physical injury. It may also be used to
warn against unsafe practices.
NOTICE Indicates a potentially hazardous situa-
tion. If not avoided, it could result in
damage to the product or environment.
Option
Mounting on a flat surface Use a drilling template (part number
45 44 299) and attach it using 4
screws (M6 x 10).
Mounting to a bar or beam Mount kit (part number 45 44 198)

Installation | en
Assembly instructions | Docking Station for Ex e version of Polytron® 5000/8000 9
2. Pull the hinge pin out of the Docking Station.
3. Align the gas detector hinge with the Docking Station hinge and reinsert the
hinge pin.
The gas detector is attached and can be opened to gain access to the
wiring.
4. Connect the cable bushings of the gas detector to the Docking Station.
In the case of a cable bushing with stranded wires, observe the terminal
assignment .
The plug locks must engage.
5. Connect the ground wire to the ground connection (torque 1.2 Nm).
6. Wire the Docking Station as described in Installation chapter.
7. Check the electrical installation to ensure that all conductors are properly
connected.
8. Screw the gas detector onto the Docking Station with 4 screws and a torque
of 8 Nm (70 LB IN.). The 4 screws are included in the delivery (M6 1/4 "
hexagon socket head cap screws).
6 Installation
WARNING
The electrical installation must only be carried out by experts. During
installation, all wiring must conform to the relevant, applicable national
regulations relating to the installation of electrical equipment and, where
applicable, the regulations for installation in potentially explosive areas. In case
of any doubt, obtain the relevant information from the appropriate official body
before executing the installation.
CAUTION
Do not apply power before the electrical installation is complete and has been
checked. Do not pull on cables to unplug!
NOTICE
For installation of the conductors onto the terminal block, a screwdriver or the
special enclosed tool is required.
Observe the following during installation:
– When installing at locations exceeding ambient temperatures of 55 °C
(149 °F), use only appropriate wiring specified for at least 25 K above the
maximum ambient temperature.
– Strip wire insulation by 5-7 mm (0.2 - 0.25“).
– Minimum wire size:
– Polytron SE EX sensing heads: 0.7 mm2 (AWG 21).
– Relay connection: 1 mm2 (AWG 18)
– Limitations for daisy-chaining gas transmitters (HART multi-drop): 2 flexible
wires, wire size 1 mm2 (crimped together with ferrule within a cage clamp).
– For remote installations, the maximum permissible distance between the
gas detector and the sensors is 30 m (100 ft).
– For the fieldbus version, only shielded cables may be used.
6.1 Terminal assignment
6.1.1 Version: Cable bushing with stranded wires, Figure A1
Power supply and signal output only
Terminal block for power supply and analog signals
Only for Polytron 5100 EC:
Terminal block for power supply for 2-wire installation
Mounting in a tube/duct Duct mount kit (part number
68 12 725)
For Polytron® 57x0 IR / 87x0 IR Part
number: 68 12 300
Option
Terminal 1 2 3
Assignment + - 4-20 mA signal
Terminal 1 2 3
Assignment ± open 4-20 mA signal

10 Assembly instructions | Docking Station for Ex e version of Polytron® 5000/8000
en | Installation
6.1.2 Version: Cable bushing with plugs, Figure A2
Power supply, connection of sensing heads, relay, digital or analog signals
Terminal block for power supply and analog signals, Figure D
Terminal block for relays, Figure D
The outputs of the relay terminal are factory-set to normally open (NO) and
common (COM).
Terminal block for connecting sensing heads, Figures F and G
Terminal block for power supply of fieldbus connection, Figure E1
Terminal for Modbus RTU connection, Figures E2
Terminal 1 2 3 4 5
Assignment + - - 4-20 mA
signal
PE
Terminal 1 2 3 4 5 6 7
Assign-
ment
Fault Fault Alarm
2
Alarm
2
Alarm
1
Alarm 1 PE
Terminal1) 1 2 3 4 5
Dräger PIR 7000 Type 334
(M25) complete set 6811825
Green/
yellow
White Brow
n
Black Red
Dräger PIR 7000 Type 340
(M25) complete set 6811819
Dräger PIR 7200 (M25)
complete set 6812290
Sensing Head Polytron SE
Ex PR M1 DD/DQ 6812711
Black Bridge
terminal
2 with
terminal
12)
Yel-
low
Bridge
terminal
4 with
terminal
52)
Brow
n
Sensing Head Polytron SE
Ex PR M2 DD/DQ 6812710
Sensing Head Polytron SE
Ex HT M DD/DQ 6812720
Sensing Head Polytron SE
Ex LC M1 DD/DQ 6812722
Sensing Head Polytron SE
Ex LC M2 DD/DQ 6812721
Sensing Head DrägerSensor
IR, complete set e 6811165
Sensing Head DrägerSensor
IR, complete set e 6811265
1) The numbering of the terminal block on the Docking Station does not always correspond to the
numbering on the sensor or the complete set. The color coding is crucial.
2) The operator must ensure the correct version by using suitable cable cross-sections/ferrules.
Terminal PWR + PWR - SCR
Assignment Voltage + Voltage - Shield
Terminal FB + FB - COM SCR
Assignment Signal line
A
Signal line B Grounding Shield
Terminal1) 1 2 3 4 5