DOSPEL luna 200 Manuel utilisateur

snapchat: dospel.com
www.dospel.com
twitter.com/dospel_com
facebook.com/Dospel.Wentylacja
Below documentation shall be kept by user!
In case of not following the conditions of this document, the warranty expires.
MAINTENANCE MANUAL
WARRANTY CARD
AIR HANDLING UNIT
luna 200
rew. 2.02.2018
EN

1. GENERAL INFORMATION......................................
1.1. Purpose......................................................
1.2. Technical specification....................................
2. ASSEMBLY.......................................................
2.1. Required exploitation conditions.........................
2.2. Assembly of siphon out condensate.....................
2.3. Connecting to power grid.................................
3. STARTING THE UNIT..........................................
3.1. General remarks............................................
3.2. Starting the unit............................................
3.3. Summer mode.............................................
3.4. Exploitation recommendation..........................
3.5. Controller maintenance manual........................
4.WARRANTY.....................................................
3
3
3
5
5
6
7
9
9
9
10
11
12
12
luna 200
EN

1. BASIC INFORMATION
1.1 Purpose
Luna 200 air handling unit is designed to assure air exchange in residential buildings.
The unit's puprose it to supply fresh air from the outside and dispose used air from
the rooms with simultaneous recovery of thermal energy. As standard, the unit
is equipped with with bypass which can be switched on without opening the casing.
1.2 Technical data
Chart 1. Technical specification
148 [mm]
1108 [mm] x 564 [mm] x 494 [mm]
Dimension
Connection diameter
Air flow (100Pa)
Disposal compression
Max. power consumption
Heat recovery efficiency
Power supply voltage
Power / Motor supply voltage
Motor rotational speed
Type of motor's bearing Roller
Acoustic pressure
Insulation class
International Protection Rating
Weight
LUNA 200
3
200 [m /h]
0-350 [Pa]
maks. 140 [W]
do 95%
230 VAC/50Hz
2x68[W] / 230 [VAC]
2400 [obr./min]
51 [dB]
II
IP44
20 [kg]
luna 200
EN

WARNING!
Luna 200 should be lifted by holding the casing. It is forbidden to lift
by holding the connectors. It may result in leakage and damage to the
device.
Fig.1. Nominal dimensions LUNA 200
1108
564
459,8
171,4
Ø148
494
450
870
Fig. 2. Flow efficiency characteristics LUNA 200
3
Airlfow [m /h]
Pressure [Pa]
50
0
100
150
250
200
300
350
400
0 100 200 300 400 500
luna 200
EN

2. Assembly
2.1. Required exploitation conditions
The unit and ducts should be assembled in rooms with temperature above 5°C and heat-
separated form surroundings.
Not following above conditions will cause liquefaction of condensate and cumulate
it inside and outside of the unit which may cause dampness in the room or damage
to the unit.
WARNING!
1. Ventilation installation and other belonging elements must be in accordance with
Polish Norms referring to ventilation in residential buildings.
2. The unit is not destined for drying the unseasoned houses.
3. In case of damage to elements arising from not following the above instructions,
they will be not repaired under warranty.
4. Due to design reasons there is a possibility of mixing the air inside the unit with
amount not exceeding 2%.
luna 200
EN

2. Assembly of condensation dreinage system
Steam condensation can be observed during unit's work. It is completely normal
and it does not mean abnormality in working. In order to siphon out condensate the unit
is equipped with stub pipe placed on the right side. It is essential to properly connect
the pipe siphoning out the condensate.
Exemplary way of conneting the pipe is shown below. The pipe should have adequate
diameter to the stub-pipe (16 mm). It shoud be bent into letter "U" and suffused
with water until stabilizing its level. Shipon should be palced around 120 mm from the
unit and radius should not be less than R=30 mm. Given measures should be taken
as minimal. Unit is sold with siphon and pipe,
Fig.3. Connection of ventilation ducts
To launcher
From air inlet
From rooms
To rooms
luna 200
EN

2.5. Conneting to power grid
Unit should be connected directly to one phase outlet 230V/50Hz in the most accessible place.
2 2
Unit comes with 2 m power cord and connection box to which 5x1mm or 5x1,5mm power cord
and 3-gear controller shoud be connected. Power cord should be properly led
to connection box with (in accordance with schemes). Such installation should be secured with
proper fuse (overcurrent braker, etc.). All electrical matter should be perfomed by authorized
person.
WARNING!
Prior to maintenance work or repairs, unit should be disconnected from the power outlet
by pulling the plug out.
In case of damaging the wire, replacement can only be performed by authorized person.
rev: 22.01.18
Fig. 4. Connection boxFig. 4. Place of pipe
Siphon
luna 200
EN

Manner of connecting 3 gear controller
Power cord
2
3x1,5mm
Control - power supplying cord
2
5x1mm
Switchboard
supplying the building
Main power supply
230V AC 50Hz
Luna 200
5x0,5
5x0,5
5x1
OFF
HI LO
MED
DOSPEL
L
L
LL
LL
LL
LL
N
N
N
N
PE
PE
PE
PE
C
C
LM
LM
LM
LM
LH
LH
LH
LH
NPE
LO M H
OFF
M
exhaust
~230,
max. 70W
M
intake
~230,
max. 70W
3 gear controller
WARNING!!!
Supply voltage VAC, 50Hz
(the current protection should be selected based on the device's power)
3 gear controller
connection box
connection
box
luna 200
EN

3. STARTING THE UNIT
3.1. General remarks
1.Prior to starting the unit read the manual.
2.Check if there is no objects present in the ducts which may damage the unit
or endanger health.
3.It is recommended to test the working mode of the unit prior to connecting
it to ventilation.
WARNING!
While testing the installation follow the safety rules in order to avoid improper
direction of airflow, i.e. open chimney duct or other devices with open fire towards
room.
3.2. Starting the unit
1.Read the manual
2.See if there is no damage
3.Place unit in wanted place
4.Connect 3 gear controller
5.Connect connection cord to connection box (in accordance with schemes) then
to 3 gear controller
6.With 3x1,5 mm2 (secured by fuse) 230v/50Hz connect to 3 gear controller.
7.Turn on the unit switching to wanted gear (LO, MED, HI)
8.Turn off the unit (OFF)
Once all above is performed, the unit can be used.
Usage and maintenance
When proprely installed, unit does not require special maintanance work during use. It is
recommended to control filters at least once per quarter and change filters. It is
essential for keeping unit's high efficiency. When high intake air purity of is required, it is
recommended to use external duct filter.
rev: 22.01.18
luna 200
EN

In order to replace filters, remove securing screws, take off one part of casing, remove
used filters and replace with new ones. After replacing filters timer needs to be reset.
WARNING!!!
Unit should not work without filters. It is only recommended for testing,
but no longer than 10 minutes.
3.3. Summer mode
Luna 200 is equipped with baypass which is activated by lever placed on the casing.
The moment when bypass is opened, heat exchange does not take place. To open bypass
turn lever by 90 degree counterclockwise. Bypass helps to cool ventilated rooms with
use of i.e GWC.
Fig.5. Manner of replacing filters
Exchanger Filters
Casing
luna 200
EN