Doro CareIP Mobile Manuel utilisateur

Doro CareIP® Mobile
User Guide
English

2
www.doro.com/care Doro CareIP®
Table of contents
1. Read first: Safety information ................................................ p.2
2. Important information........................................................... p.3
3. Package contents................................................................... p.3
4. Parts and descriptions ........................................................... p.4
5. Description of functions ........................................................ p.6
6. Installation............................................................................ p.7
7. Communication path ............................................................. p.9
8. Pairing................................................................................. p.10
9. Radio trigger Elliot .............................................................. p.12
10. General information ............................................................ p.14
11. Maintenance ....................................................................... p.14
12. Technical data ..................................................................... p.15
1. Read rst: Safety informaon
Always read and follow the safety informaon accompanied by this symbol.
• User’s should pay parcular aenon to the potenal for interference from other
systems operang in the same or adjacent bands.
• The compartment covers on the backside may be opened only by authorised
persons in accordance with the instrucons in the service manual.
• Baery replacement may be performed only by authorised persons in accordance
with the instrucons in the Maintenance secon. Only use recommended baery
type as stated in the Technical Data secon.
CAUTION
Only use baeries, power supply and accessories that have been
approved for use with this parcular model. Connecng other
accessories may be dangerous and may invalidate the type approval and
guarantee.
• The antenna shall always be mounted if the unit is in operaon.
• Only use recommended power supply as stated in the Technical Data secon.
• The power supply can be used as a disconnecng device. The wall socket shall be
installed near the equipment and shall be easily accessible.

3
Doro CareIP®www.doro.com/care
2. Important informaon
All systems using radio and network communicaon are subject to interference
beyond the user’s control.
Products from Doro are designed to minimise the impact of such interference.
Nevertheless, the user must be aware that system components can be subjected to
interference or other inuences that may cause malfuncon.
It is therefore important to regularly check that every part of the system works in all
areas, especially radio communicaons. Contact your supplier immediately in case of
any suspected malfuncon.
Users should pay parcular aenon to the risk of disrupon from products which
communicate using the same or adjacent frequencies.
For further informaon, please contact your supplier or refer to the service manual or
the documentaon at www.doro.com/care.
3. Package contents
Doro CareIP® Mobile carephone
(arcle number 100007, DE Art,-Nrn: 1-9300-210)
• Network cable (cat5E UTP TIA568B)
• Power supply
• Antenna
• User guide
• Elliot radio trigger with accessories:
• Wristband
• Wristband aachment
• Neckband
• Neckband aachment
• Pocket clip
• Easy press concept (EPC) accessory

4
www.doro.com/care Doro CareIP®
4. Parts and descripons
Indicator lights:
1ALARM RED
Steady light Idle mode
Flashing light Alarm state
2ON GREEN
Steady light Mains power
Flashing light Mains failure or pairing mode
3ERROR RED
O Normal operaon
Steady light Problem with Ethernet link* or
IP conguraon
* If only Mobile interface is used it will lit as
Ethernet isn´t connected, the Ethernet link
supervision can be disabled by conguraon
Slow ashing Registraon to SIP server failed
4STATUS RED / GREEN
O Normal operaon
Steady red light No connecon to GSM network
Alternang red and green Away mode
Antenna:
5Antenna
Aach the supplied antenna to the antenna connector, see Connecons
overview on p. 5.
Buons (with the following standard funcons):
6Green buon
Stops the alarm
7Yellow buon
Funcon buon
8Red buon
Acvates the alarm
Note! The yellow buon has no funcon upon delivery but is programmable for
special funcons.

5
Doro CareIP®www.doro.com/care
Connecons overview
1Volume control Loudspeaker volume adjustable in eight levels.
2PC (Pull cord) Aachment for pull cord when wall mounted. The
pull cord can be ordered separately.
3Holes for wall mounng -
4Baery compartment -
5I/O connectors Terminals for wire outputs and inputs.
6Ethernet port Connecon for Ethernet cable from broadband/
network.
7DC in Connecon for power supply 7,5 VDC.
8Power switch Turns Doro CareIP® Mobile on and o.
9Antenna connector A standard antenna is delivered, if other antenna
will be used it must be adapted for use with
Doro CareIP® Mobile
10 SIM card Ssee Install the SIM card on p. 7.
CAUTION
Only authorised persons may open the compartment covers and
perform wiring in accordance with the instrucons in the service
manual.

6
www.doro.com/care Doro CareIP®
5. Descripon of funcons
Doro CareIP® Mobile is a digital alarm unit with a built in GSM module, the unit
has possibility to transfer alarms over broadband/network connecons and mobile
telephone networks. The unit oers the user the possibility of two way voice
communicaon using exisng standard for VoIP (Voice over Internet Protocol) calling.
The unit uses SIP, a standard protocol to iniate speech and video over broadband
connecons. In addion to voice connected alarm calls, Doro CareIP® Mobile oers
a plaorm for transfer of detailed alarm informaon, speech messages, online status
etc.
The Doro CareIP® Mobile is assigned an unique idencaon number (ID) that is
transferred and corresponding to personal informaon stored in the alarm receiving
centre (ARC).
The Elliot radio trigger is adapted for use with the unit, see 9. Radio trigger Elliot on p.
12.
Acvate the alarm
The assistance alarm can be acvated:
1. by pressing the buon on a radio trigger.
2. by pressing the red buon on the Doro CareIP® Mobile.
3. by pulling the pull cord (only available when Doro CareIP® Mobile is wall
mounted). The pull cord can be ordered separately.
On acvaon, the Doro CareIP® Mobile calls an alarm receiver to summon help. There
is a possibility to aach up to four (4) dierent wired alarm triggers.
Alarm transmiers
Ten (10) radio transmiers can be programmed with the Doro CareIP® Mobile, e.g. a
radio trigger. In the event of an alarm from a radio transmier, the baery status of
the radio transmier is tested.
Alarm receivers
Up to ten (10) alarm receivers can be programmed. The alarm is idened using an
alarm code which is programmed into the Doro CareIP® Mobile. An alarm placed to a
private receiver is idened by a recorded voice ID.
The person receiving the alarm can then speak directly with the person raising the
alarm and take appropriate acon.
Other funcons
Addional funcons can be acvated or modied – refer to the service manual or
contact your supplier for further informaon.

7
Doro CareIP®www.doro.com/care
6. Installaon
Install the SIM card
IMPORTANT
Turn o the phone and disconnect the charger before removing the
baery cover.
• Ensure that the Doro CareIP® Mobile is switched o before.
• Unscrew the safety screw for the SIM card compartment cover.
• Remove the compartment cover.
• Install the SIM card according to picture , note the markings.
• Mount the cover and the safety screw for the SIM card compartment.
CAUTION
1234 or 0000 are not appropriate PIN codes for the SIM card, if any
of these PIN codes are used, the code should be changed before
installaon. Change of PIN code is preferably done using a mobile phone.

8
www.doro.com/care Doro CareIP®
Connecon
The Doro CareIP® Mobile is easy to install, if broadband/network connecon
shall be used, connecon is made with the enclosed network cable. Normally the
Doro CareIP® Mobile is set to use DHCP, which means that the unit automacally will
be assigned an IP address when connected to a network. The Doro CareIP® Mobile
should always be connected to the network as near the router (or Ethernet
connecon) as possible.
1. Connect the power supply (1) to the wall socket and the power supply lead to
the DC input socket.
2. Connect the network cable (2) from the broadband/network to the Ethernet
socket on Doro CareIP® Mobile.
• Turn the power switch to the I posion
• Check that the On !indicator lamp has a steady green light
• The status light shall go o within 60 seconds if GSM network is detected
• Carry out a test alarm from the Doro CareIP® Mobile
Note! The power supply shall be placed so that the informaon scker Do not unplug is
visible. For further advice regarding installaon, contact your supplier.
CAUTION
Installaon must be performed only by authorised persons in accordance
with the instrucons in the service manual.

9
Doro CareIP®www.doro.com/care
7. Communicaon path
Example of a simplied communicaon path
1.
ARC
Elliot
4
CareIP®
Mobile
Internet
i-care
online
SRD Radio, social alarm frequency
2.
a. Mobile connecon to GSM/GPRS, Voice, IP alarm protocol and addional
data
b. IP on Ethernet, VoIP, IP social alarm protocol and addional data
3. IP connecon through GPRS
4. Voice connecon through GSM*
5. IP connecon to a digital Alarm Receiving Centre (ARC)
6. Oponal connecon to i-care online system
* Can also carry alarm data to an analogue Alarm Receiving Centre (ARC).

10
www.doro.com/care Doro CareIP®
8. Pairing
Contacts, alarm codes and sengs are programmed using www.icareonline.com or by
using a computer and the Doro Care CS2 soware.
In some cases, the Doro CareIP® Mobile can be delivered pre-programmed by the
supplier. For help with pairing, please refer to the service manual or contact your
supplier.
Pairing radio triggers
Up to ten (10) radio triggers or other radio-alarm transmiers can be paired to
Doro CareIP® Mobile.
Pairing radio transmiers:
• Hold down the green buon for approximately four seconds unl the unit emits a
beep, release the buon. The indicator light On ! ashes green.
• Press the radio trigger. Once the Doro CareIP® Mobile receives the radio signal, you
will hear a disnct tone signal.
• Conrm by pressing the red buon, you will hear a conrmaon tone.
Check the radio coverage
Always check the funcon aer installaon and pairing.
• Hold down the green buon for approximately four seconds unl the unit emits a
beep, release the buon. The indicator light On ! ashes green.
• Press the radio trigger. Once the Doro CareIP® Mobile receives the radio signal, you
will hear a tone.
Autres manuels pour CareIP Mobile
1
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Doro Système de sécurité
Manuels Système de sécurité populaires d'autres marques

EDM
EDM Solution 6+6 Wireless-AE Manuel utilisateur

Highway Safety Group
Highway Safety Group EA401 Manuel utilisateur

Siren
Siren LED GSM Manuel utilisateur

Detection Systems
Detection Systems 7090i Instructions de montage

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuel utilisateur

Siemens
Siemens FDM273 Manuel utilisateur