Dolby Laboratories Program Optimizer DP600 Manuel de la liste des pièces

Dolby DP600
Hard Drive
Replacement Guide
Issue 1 Part Number 9110440
®

ii Dolby®DP600 Hard Drive Replacement Guide
Dolby Laboratories, Inc.
Corporate Headquarters
DolbyLaboratories,Inc.
100PotreroAvenue
SanFrancisco,CA 94103‐4813 USA
Telephone415‐558‐0200
Fax415‐863‐1373
www.dolby.com
European Headquarters
DolbyLaboratories,Inc.
WoottonBassett
Wiltshire SN48QJ England
Telephone44‐1793‐842100
Fax44‐1793‐842101
DISCLAIMEROFWARRANTIES:
EQUIPMENTMANUFACTUREDBYDOLBYLABORATORIESISWARRANTEDAGAINSTDEFECTS
INMATERIALSANDWORKMANSHIPFORAPERIODOFONEYEARFROMTHEDATEOF
PURCHASE.THEREARENOOTHEREXPRESSORIMPLIEDWARRANTIESANDNOWARRANTY
OFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE,OROFNONINFRINGEMENT
OFTHIRD‐PARTYRIGHTS(INCLUDING,BUTNOTLIMITEDTO,COPYRIGHTANDPATENT
RIGHTS).
LIMITATIONOFLIABILITY:
ITISUNDERSTOODANDAGREEDTHATDOLBYLABORATORIES’LIABILITY,WHETHERIN
CONTRACT,INTORT,UNDERANYWARRANTY,INNEGLIGENCE,OROTHERWISE,SHALLNOT
EXCEEDTHECOSTOFREPAIRORREPLACEMENTOFTHEDEFECTIVECOMPONENTSOR
ACCUSEDINFRINGINGDEVICES,ANDUNDERNOCIRCUMSTANCESSHALLDOLBY
LABORATORIESBELIABLEFORINCIDENTAL,SPECIAL,DIRECT,INDIRECT,OR
CONSEQUENTIALDAMAGES(INCLUDING,BUTNOTLIMITEDTO,DAMAGETOSOFTWAREOR
RECORDEDAUDIOORVISUALMATERIAL),COSTOFDEFENSE,ORLOSSOFUSE,REVENUE,OR
PROFIT,EVENIFDOLBYLABORATORIESORITSAGENTSHAVEBEENADVISED,ORALLYORIN
WRITING,OFTHEPOSSIBILITYOFSUCHDAMAGES.
.
Dolbyandthedouble‐DsymbolareregisteredtrademarksofDolbyLaboratories.
©2009DolbyLaboratories.Allrightsreserved.
PartNumber9110440
Issue1
S09/21035

Dolby®DP600 Hard Drive Replacement Guide 1
DP600 Hard Drive
Replacement Instructions
ThisdocumentexplainshowtoreplaceaDP600harddrive.Beforeyoubegin,besureyou
havethefollowing:
• Phillipsscrewdriver
•Harddrivereplacementkit(DP600HD‐SPK)withharddrive(Cat.No.898‐7‐P)
Pleasereadthisentiredocumentbeforeyoubegintheprocedure.Theprocedurewilltake
approximately30minutes.
Replacing a Hard Drive
TheDP600hasfivephysicalinternalharddrives.Drives1and2arearrangedinaRAID1
configurationtoprovideprotectionfortheoperatingsystemandlocalstorage.The
remainingthreeharddrivesareconfiguredasseparatedrivestoprovidelocalstorage.This
configurationofoneRAIDpairandthreeseparatedrivesrepresentsfourlogicaldrives.
TherearefourbicolorLEDsonthefrontpanel,labeled1,2,3,and4.TheseLEDsindicate
thestatusoftheDP600’sfourlogicalinternalharddrives.ThedriveLEDsfunctionas
follows:
•Off(nonilluminated):Indicatesafunctionaldrivewithnocurrentdiskaccessactivity
•Green:Indicatesnormaldriveactivity
•Red:Indicatesadrivefailure
LED1 showsthestatusofthetwo‐driveRAID1configuration.Theoperatingsystemis
installedonthesemirroreddrivestopreventaphysicaldrivefailure,resultinginan
inoperablesystem.Ifeitherofthemirroreddrivesfails,theotherRAIDdriveenablesthe
systemtooperatenormallyuntilthefaileddriveisreplaced.
LEDs2,3,and4indicatethestatusoftheotherthreephysicaldisks.Thesedisksare
configuredasseparatedrivesanddonothaveRAIDbackupcapability.Ifanyofthese
drivesfail,thefaileddrivesmustbereplaced,andanyworkordersinprogressduringthe
failuremustberestarted.
Note: Youcanpowerdowntheunitbeforebeginningthisprocedure,butitisnot
necessary.

2Dolby®DP600 Hard Drive Replacement Guide
Replacing a Hard Drive
IfoneofthedriveLEDsturnsred,refertoTable 1todeterminewhichphysicaldrivefailed.
Typically,theDP600automaticallyrebuildstheRAIDarraywhenoneoftheRAIDdrives
hasaproblemorisreplaced(withthepoweron).DuringtheRAIDrebuildprocess,LED1
blinksinredinhalf‐secondintervals.Whentherebuildprocessiscomplete,LED1stops
blinking.
Insomeinstances,youmustinitiatetherebuildprocessmanually,asdescribedattheend
ofthisprocedure(forexample,ifyoureplaceanon‐RAIDdrive).
IfyoureplacebothRAIDdrives,youalsoneedtoreinstalltheDP600software.Insucha
case,followtheinstructionsforacleaninstallationinSection3ofyourDolby®DP600
ProgramOptimizerManual.Whenyoureinstallthesoftware,thesystemautomatically
synchronizesthetwoRAIDdrives,re‐creatingtheoriginalmirroredRAIDarray(manual
rebuildnotrequired).
Table 1showstheLEDconditionsthatspecifythefaileddrive.
Toreplaceaharddrive:
1. Lookatthefront‐paneldriveLEDs,thenrefertoTable 1todeterminewhichdrivehas
failed.TheexampleinFigure 1showsthatdrive3hasfailed.
Figure1
Figure 1 Red LED Indicates Failed Disk Drive
Table 1 Local Storage LED Conditions
Front-Panel LED Condition Failed Physical Drive
1Solidred 1
1Blinksinredin
two‐secondintervals
2
1Blinksinredin
half‐secondintervals
RebuildingRAID
2Solidred 3
3Solidred 4
4Solidred 5
!
4
3
2
1
Failed drive
red LED
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
Please refer to the Addendum at the end of this document for the replacement text for this section.

Replacing a Hard Drive
Dolby®DP600 Hard Drive Replacement Guide 3
2. Swingthetouch‐screenpanelouttotheleft,asshowninFigure 2.
Figure2
Figure 2 Swing Out Touch-Screen Panel
3. Locatethesmallpryareasontherightpanel,asshowninFigure 3.
Figure3
Figure 3 Locate Pry Areas Behind Right Panel

4Dolby®DP600 Hard Drive Replacement Guide
Replacing a Hard Drive
4. Usingyourfingersoracushionedscrewdriver,gentlypryofftherightpanelfromits
leftside(theothersideisaslottedlock),asshowninFigure 4.
Becarefulnottodropit,asthepanelisdeceptivelyheavyandwillcomeoffsuddenly
oncethelockingmechanismdisengages.
Figure4
Figure 4 Remove Right Panel
Theharddrivebayisnowexposed,asshowninFigure 5.
Startingfromtheleftsideofthedrivecage,thefirstslotcontainsphysicaldrive1
(RAIDdrive1).Thesecondslotcontainsphysicaldrive2(RAIDdrive2).Startingwith
thethirdslot,physicaldrives3,4,and5areinstallednext,inthatorder.Figure 5shows
howthedrivesarenumberedfromlefttoright(numbersdonotappearontheactual
unit).
Figure5
Figure 5 Hard Drive Bay Exposed
12345

Replacing a Hard Drive
Dolby®DP600 Hard Drive Replacement Guide 5
5. Loosen(donotremove)thefourPhillips‐headscrewssecuringtheretainingbracket,
thenslidethescrewsinward,freeingthebracket.
Asviewedlefttoright,thefirsttwoscrewsmovetotherightandthesecondtwo
screwsmovetotheleft,asindicatedbytheredarrowsshowninFigure 6(thearrows
donotappearontheunit).
Figure6
Figure 6 Loosen Retaining Bracket Screws
6. Removetheretainingbracket,asshowninFigure 7.
Figure7
Figure 7 Remove Retaining Bracket
><

6Dolby®DP600 Hard Drive Replacement Guide
Replacing a Hard Drive
7. Matchthefaileddrive’snumber(determinedinstep1)withthecorresponding
physicaldrive,graspthedrive’shandle,thenpressthedrive’sfingertabandslideit
outofitsslot,asshownintheexamplesinFigure 8andFigure 9.
Figure8
Figure 8 Press on Failed Drive’s Finger Tab
Figure9
Figure 9 Slide Failed Drive out of Slot

Replacing a Hard Drive
Dolby®DP600 Hard Drive Replacement Guide 7
8. Besurethatnoworkorderisrunning,thenpressthereplacementdrive’sfingertab,
andfirmlybutgentlyslidethedriveintoitsslotuntilyoufeelresistance,which
indicatesthatthedriveisseatedinitssocket(seeFigure 10andFigure 11).
Youcanreplaceadrivewithahighercapacityunitbutnotwithalowercapacityunit.
Figure10
Figure 10 Grasp Replacement Drive’s Finger Tab
Figure11
Figure 11 Slide Replacement Drive into Slot

8Dolby®DP600 Hard Drive Replacement Guide
Replacing a Hard Drive
9. Repositiontheretainingbracket,slidethescrewsoutwardtotheiroriginalposition,
thentighteneachscrewtosecurethedrivesinplace,asshowninFigure 12.
Figure12
Figure 12 Reinstall Retaining Bracket
10. Replacetherightpanelbyfirstengagingtheright‐sideslottedhinge,andthen
pressingonthesecuringmechanismontheleft‐sideofthepanel,asshownin
Figure 13andFigure 14.
Figure13
Figure 13 Replace Right Panel Step A
Figure14
Figure 14 Replace Right Panel Step B
Autres manuels pour Program Optimizer DP600
4
Table des matières
Manuels Stockage populaires d'autres marques

Spectra Logic
Spectra Logic T-Series Spectra T50e Manuel utilisateur

Panasonic
Panasonic LKM-F931-1 Manuel utilisateur

Tabernus
Tabernus Enterprise Erase E2400 Manuel utilisateur

Rocstor
Rocstor COMMANDER 3F series Manuel utilisateur

HP
HP P9000 Manuel utilisateur

Western Digital
Western Digital Ultrastar Data60 Manuel utilisateur