DirectOut Technologies D.O.TEC M.1k2 Instructions d'installation

M.1K2
Hardware Guide
Version 1.3

page 2 of 44
M.1k2 Hardware Guide - Version 1.3
Copyright
All rights reserved. Permission to reprint or electronically reproduce any document or
graphic in whole or in part for any reason is expressly prohibited, unless prior written
consent is obtained from the DirectOut GmbH.
All trademarks and registered trademarks belong to their respective owners. It cannot
be guaranteed that all product names, products, trademarks, requisitions, regulations,
guidelines, specifications and norms are free from trade mark rights of third parties.
All entries in this document have been thoroughly checked; however no guarantee for
correctness can be given.
DirectOut GmbH cannot be held responsible for any misleading or incorrect
information provided throughout this manual.
DirectOut GmbH reserves the right to change specifications at any time without notice.
DirectOut Technologies® is a registered trademark of the DirectOut GmbH.
© DirectOut GmbH, 2016

page 3 of 44
M.1k2 Hardware Guide - Version 1.3
Table of contents
About This Document 5
How to Use This Document.......................................................................... 5
Conventions .................................................................................................. 5
CHAPTER 1: Overview 6
Introduction ................................................................................................... 6
Feature Summary.......................................................................................... 7
Applications................................................................................................... 7
CHAPTER 2: Legal issues & facts 8
Before Installing This Device......................................................................... 8
Defective Parts/Modules ............................................................................. 8
First Aid (in case of electric shock)................................................................ 9
Updates ....................................................................................................... 10
Conditions of Warranty ............................................................................... 10
Intended Operation .................................................................................... 10
Conformity & Certificates ........................................................................... 11
Contact ........................................................................................................ 11
Contents...................................................................................................... 12
CHAPTER 3: Installation 13
Installing the Device .................................................................................... 13
Network integration..................................................................................... 16
CHAPTER 4: Operation 18
Introduction ................................................................................................. 18
Global Control.............................................................................................. 18
Device State & RESET ................................................................................ 19
User data (Serial, MIDI, GPO) ..................................................................... 20
Clocking....................................................................................................... 21
Remote Operation....................................................................................... 22
CHAPTER 5: Troubleshooting and Maintenance 23
Troubleshooting........................................................................................... 23
Maintenance................................................................................................ 23
CHAPTER 6: Technical Data 24
Appendix A - Emergency recovery 26
Appendix B - DSUB-9 Pin assignments 27
RS-232 ........................................................................................................ 27
RS-4xx......................................................................................................... 27
GPO............................................................................................................. 27

page 4 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix C - Installing / Replacing I/O modules 28
Modules ...................................................................................................... 29
Appendix D - How to - Network 30
Appendix E - Firmware Update Instruction 32
Appendix F - USB Serial Driver Installation 36
Index 39

page 5 of 44
M.1k2 Hardware Guide - Version 1.3
About This Document
About This Document
How to Use This Document
This document guides you through the installation and operation of the M.1K2. For
information about the graphical user interface (GUI) please consult the offline help
available from our website or use the online help within the gui.
Use the Table of Contents at the beginning of the manual or Index Directory at the
end of the document to locate help on a particular topic. You can access more
information and latest news by visiting on the DirectOut website at
www.directout.eu.
Conventions
The following symbols are used to draw your attention to:
TIPS!
indicate useful tips and shortcuts.
NOTES!
are used for important points of clarification or cross references.
WARNINGS!
alert you when an action should always be observed.

page 6 of 44 M.1k2 Hardware Guide - Version 1.3
CHAPTER 1: Overview
CHAPTER 1: Overview
Introduction
The M.1K2 is a 16 port MADI Routing System. It provides routing of whole ports
down to single channel level offering a 1024 by 1024 crosspoint matrix.
You can distribute MADI signals en bloc in a port matrix and you may also create
your own MADI stream using the channel matrix. PolySync™ provides the ability
to use different clock sources on individual ports. So the router may be divided into
single ‘clock groups’ that can run at different sample rates.
Port redundancy may be applied to have a spare signal that will be used when an
input signal breaks. Two extra matrices may route serial data and MIDI data- that is
embedded into the MADI signal- independently from the audio signal.
Doppelganger (Device Mirroring) allows one (or more) M.1K2s to be configured
to act as a slave to one master device. All configuration data (crosspoints, port
configuration, labels etc.) is synchronized continuously.
SNMP Simple Network Management Protocol (v1/v2) allows for monitoring of
essential device information such as power supply state; temperature; MADI
signal/synchronization state.
More features such as I/O labelling, snapshot and user management offer the
chance to personalize your setup all-embracing.

page 7 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 1: Overview
Feature Summary
MADI I/Os 2 x slots with eight MADI ports each
Module types: coaxial (BNC), optical SC (multi-mode)
and SFP (multi-mode)
single-mode upon request
MADI Formats 56/64 channel, 48k/96k Frame, S/MUX 2/4
Sample Rates 30 kHz to 50 kHz
(and their multiples- 2FS, 4FS)
Clock Inputs 1 x Word clock coaxial BNC
75 Ω termination switchable
1 x Video coaxial BNC
75Ω termination switchable
Black Burst (PAL, NTSC)
Clock Outputs 2 x Word clock coaxial BNC
Serial Data / MIDI 1 x RS232 DSUB-9
1 x RS422/485 DSUB-9
1 x MIDI in/out (DIN)
GPO 4 x GPO DSUB-9
Device Monitoring SNMP v1/v2
Device Mirroring Doppelgaenger Mode
Control Plug-Ins Telnet,Pro-Bel SWP-08 (network and serial), MIDI,
Jupiter, JSON
USB Port USB 2.0 port for virtual COM port (RS 232)
Power Supply This device is equipped with two wide range power
supplies (84 V to 264 V AC / 47 Hz to 63 Hz / safety
class 1)
Applications
M.1K2 can be used for distribution and creation of whole MADI streams, routing
of single audio channels between MADI streams and independent routing of
embedded serial data and MIDI data.
Typical applications include:
• distribution of audio signals in OB van with integrated switching protocol (e.g.
SWP08)
• central switch in studio environments- PolySync™ and browser control
• connection between remote mic preamps and mixing consoles (serial matrix)
• show control using snapshots
• fallback system- port redundancy, device mirroring
• ...

page 8 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 2: Legal issues & facts
CHAPTER 2: Legal issues & facts
Before Installing This Device
WARNING!
Please read and observe all of the following notes before installing
this product:
• Check the hardware device for transport damage.
• Any devices showing signs of mechanical damage or damage from the
spillage of liquids must not be connected to the mains supply, or
disconnected from the mains immediately by pulling out the power lead.
• All devices must be grounded. The device is grounded through its
IEC power connections.
• All devices must be connected to the mains using the three-cord power
leads supplied with the system. Only supply electrical interfaces with the
voltages and signals described in these instructions.
• Do not use the device at extreme temperatures. Proper operation can
only be guaranteed between temperatures of 5ºC and 45ºC and a
maximum relative humidity of 80%, non-condensing.
• The cabinet of the device will heat up. Do not place the device close
to heating sources (e.g. heaters). Observe the environmental conditions.
Defective Parts/Modules
WARNING!
This device contains no user-serviceable parts. Therefore do not open the device.
In the event of a hardware defect, please send the device to your DirectOut
representative together with a detailed description of the fault.
We would like to remind you to please check carefully whether the failure is
caused by erroneous configuration, operation or connection before sending parts
for repair.

page 9 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 2: Legal issues & facts
First Aid (in case of electric shock)
WARNING!
• Do not touch the person or his/her clothing before power is turned off,
otherwise you risk sustaining an electric shock yourself.
• Separate the person as quickly as possible from the electric power source
as follows:
- Switch off the equipment.
- Unplug or disconnect the mains cable.
• Move the person away from the power source by using dry insulating
material (such as wood or plastic).
• If the person is unconscious:
- Check their pulse and reanimate if their respiration is poor.
- Lay the body down and turn it to one side. Call for a doctor immediately.
• Having sustained an electric shock, Always consult a doctor.

page 10 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 2: Legal issues & facts
Updates
DirectOut products are continually in development, and therefore the information
in this manual may be superseded by new releases. To access the latest
documentation, please visit the DirectOut website:
www.directout.eu.
WARNING!
No compensation can be claimed for damages caused by operation of this unit
other than for the intended use described above. Consecutive damages are also
excluded explicitly. The general terms and conditions of business of DirectOut
GmbH are applied.
Conditions of Warranty
This unit has been designed and examined carefully by the manufacturer and
complies with actual norms and directives.
Warranty is granted by DirectOut GmbH over the period of two years for all
components that are essential for proper and intended operation of the device. The
date of purchase is applied for this period.
Consumable parts (e.g. battery) are excluded from warranty claims.
WARNING!
All claims of warranty will expire once the device has been opened or modified, or
if instructions and warnings were ignored.
For warranty claims please contact the dealer where your device was acquired.
Intended Operation
M.1K2 is designed for distribution of MADI signals (AES10) and routing of serial
data (RS-232 and RS-422/485) and MIDI data.
Table des matières
Autres manuels DirectOut Technologies Routeur réseau
Manuels Routeur réseau populaires d'autres marques

NETGEAR
NETGEAR FS526T - Switch Manuel utilisateur

Korenix
Korenix JetNet 5710G Series Manuel utilisateur

Automated Logic
Automated Logic ZN551 Manuel du propriétaire

Cisco
Cisco ASR 1000 Series Manuel de l'opérateur

EnGenius
EnGenius ESR-9710 Manuel utilisateur

Cisco
Cisco 805 Series Instructions d'utilisation et de sécurité