DiFluid Omni Manuel utilisateur

DiFluid Omni
User Manual
English 简体中文 日本語

1. Know Your Omni
Buttons
(Power / Test / Calibration)
Touchscreen
Omni Main Unit
1

USB-C Charging Port
Deeper side for
coffee beans
Shallower side
for coffee ground
Magnetic Connector
Reverse
Tray
Roast Analysis Tray
Particle Analysis Tray
2

Name
Model
Dimensions (Main Unit)
Screen
Weight (Main Unit)
Battery
Light Source (Roast Analysis)
Optical Sensor
Data Records
Operating Temperature
Professional Roast / Particle Analyzer (2-in-1)
DFT-SD101
109*79*72mm(L*W*H)
2.8-inch HD touchscreen
290g
2500mAh rechargeable lithium battery
Multi-band NIR light source (850nm, 940nm)
Two-dimensional imaging sensor
500 Roast Analysis Records / 500 Particle Analysis Records
0-45℃
USB-C
5V 1A
Charging Port
Charging Parameters
2. Product Parameters
Specs
3

500 Roast Analysis Records / 500 Particle Analysis Records
3. Preparation Before Use
APP Download
Particle Analysis Tray *1
Roast Analysis Tray *1
Tray *1
Calibration Plate *1
USB-C Charging Cable *1
Omni Main Unit *1
Coffee Spoon *1
Brush*1
Scraper *1
Coffee Ground Spoon *1
Velvet Bag *1
Protective Film*1
Toolbox*1
Test Report *1
Manual (including warranty card)*1
Accessories
Scan the QR code below to download the DiFluid Café App
.
4

Charging: Please ensure that the battery is fully charged. Attach the Omni Main Unit to the
Particle Analysis Tray and connect the included charging cable to the USB-C port
of the side of the Particle Analysis Tray for charging.
Note: If you turn on the device during charging, the device will rst display the"DiFluid"
page, and then enter the charging status page.You need to short press the button again
to enter the "READY" page.
!
Charging and Icons
Attach the Omni Main Unit to the
Particle Analysis Tray. Plug charging wire into the port of
particle tray.
1 2
5

4. Basic Operation
Power-off State
Press the button once to start the device. When the screen displays "READY", the device
has nished booting up.
Power-on State
Short click: Perform the test.
A short click followed by a long press: Roast degree calibration.
Quick double-click: View device information.
Long press: Press and hold the button, and the screen will display "Power Off". Release
the button to complete the shutdown operation.
Operate with Button
Icon
Description Fully
charged Charging Bluetooth
connected
WIFI
connected Bluetooth and
WiFi connected
51%
Operate with Touchscreen
6

Swipe right to access the menu page
1. Roast : Perform roast analysis.
2. Particle: Perform particle analysis.
3. Calibration: Perform the calibration.
4. Settings: Access more settings for Omni.
Swipe left to access the analysis history page
1. View Roast Analysis History: Swipe left from the Home Page to view the last roast analysis
result, and swipe down to access all roast analysis history.
2. View Particle Analysis History: Swipe left twice from the Home Page to view the last particle
analysis result, and swipe down to access all particle analysis history.
On the Home Page, tap to perform the test.
On a sub-page, swipe right to return to the previous level page.
Left Page
MenuSettings
Home Page
Tap the screen,
Perform the Test
Right Page
Last Roast Analysis
Result
Second Right
Page Last Particle
Analysis Result
Swipe right Swipe left Swipe left
Full
City
Ratio:34%
43.9
Agtron
(COMMON)
Roast
Medium
Ratio:58%
Counts:174
(ISO)
Particle
980
μm
SettingsCalibration
Roast Particle
7

There are three methods to start the test
1. Click the button: In smart test mode, the system will automatically determine whether to
perform roast analysis or particle analysis.
2. Tap the screen on the Home Page: In smart test mode, the system will automatically
determine whether to perform roast analysis or particle analysis.
3. Click the <Roast> or <Particle> option on the menu page: The system will directly execute
the corresponding analysis.
5. Function operation
Test
Roast analysis
1. Recommended Procedure
1) Use a roast analysis tray and a tray. Fill the beans into deeper side while the coffee ground into
shallower side. Note that you need to use a Scraper to make it ush with the surface of the tray.
2)
Click to power up, put the main unit over the roast analysis tray.
3)
Swipe from left to right on READY page to enter the menu page. Click on the 'Roast'
button
to start test. The screen will display result after complete. (See page 11 for more details)
2. Analysis Result
(See Page 12 For More Details)
3. Cautions
1)
Light Source: Roast analysis utilizes near-infrared light sources (850nm, 940nm) for testing
and analysis. White light is used for auxiliary functions such as smart tests and 0-6 silver skin
detection
2)
Silver Skin Detection: You can choose whether to enable the silver skin detection function for
coffee beans or coffee grounds in the settings.You can also adjust the sensitivity of it.
8

Particle Analysis
1. Recommended Procedure
1)
Use a coffee ground spoon to scoop an appropriate amount of ground coffee into the center
area of the particle analysis tray.
2) Click to power up, put the main unit over the particle analysis tray. Make sure the meganetic
ports are connected.
3) Swipe from left to right on READY page to enter the menu page. Click on the 'Particle' button
to start test. The screen will display result After the completion of the test. (See page 13
for more details)
2. Analysis Result
(See Page 14 For More Details)
3. Test
1)
If the amount of coffee ground taken is more than one at spoon, the analysis of ner
particles may be affected.
2)
After the Smart Diffusor function is turned on, it can automatically conduct diffusion according
to the current particle distribution. If the particles have already been evenly distributed, the
diffusion will not be carried out again.
3)
During testing, the particle analysis tray will beep when diffusing the particle, which is a
normal phenomenon.
4. Sampling Recommendations
1)For coarse grind, please take two-thirds of a spoonful of ne powder.
2)For ne grind, please control it to one-third of a spoonful of ne powder.
3)If the grind cannot be determined, please take half a spoonful of ne powder.
4)You can adjust the sampling amount according to the actual situation to achieve better
dispersion and uniformity.
9
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur