Dentsply Sirona Hub Manuel utilisateur

New as of:
Operator's manual
09.2017
Hub
English
=
Title page


66 37 727 D3667
D3667.208.01.02.02 09.2017 3
Dentsply Sirona Table of contents
Operator's manual Hub
båÖäáëÜ
Table of contents
1General information................................................................................................. 5
1.1 Contact information ...................................................................................... 5
1.2 Open source software .................................................................................. 5
1.3 Conformity with the Directives...................................................................... 5
1.4 Symbols........................................................................................................ 5
2Safety ...................................................................................................................... 7
2.1 General safety information ........................................................................... 7
2.2 Electrical voltage .......................................................................................... 7
3System description .................................................................................................. 8
3.1 Scope of supply............................................................................................ 8
3.2 Scope of functions........................................................................................ 8
3.3 Data security ................................................................................................ 8
3.4 Hub (hardware) ............................................................................................ 9
3.5 Critical Ops USB Key ................................................................................... 10
3.6 Hub Control Center (Software)..................................................................... 10
3.7 Compatible CEREC software....................................................................... 10
3.8 System requirements ................................................................................... 10
3.9 Technical data.............................................................................................. 11
4Commissioning........................................................................................................ 12
4.1 Installing the Hub.......................................................................................... 12
4.2 Connecting the hub ...................................................................................... 12
4.3 Installing the Hub Control Center ................................................................. 13
4.4 Setting up the Hub (new unit)....................................................................... 14
4.5 Selecting the Hub as the storage location.................................................... 14
4.6 Setting up the spare unit .............................................................................. 14
5Configuration ........................................................................................................... 15
5.1 Overview of the Hub Control Center ............................................................ 15
5.2 Changing the language of the Hub Control Center ...................................... 15
5.3 Configuring the Hub ..................................................................................... 16
6Maintenance............................................................................................................ 17
7Disposal................................................................................................................... 18


66 37 727 D3667
D3667.208.01.02.02 09.2017 5
Dentsply Sirona 1General information
Operator's manual Hub 1.1Contact information
båÖäáëÜ
1General information
1.1 Contact information
Customer service center For technical questions, use the contact form on the internet at the
following address:
http://srvcontact.sirona.com
Manufacturer's address
Sirona Dental Systems GmbH
Fabrikstrasse 31
64625 Bensheim
Germany
Tel.: +49 (0) 6251/16-0
Fax: +49 (0) 6251/16-2591
e-Mail: [email protected]
www.dentsplysirona.com
1.2 Open source software
This product contains open source software. For more information,
please refer to the Licence.pdf in the installation directory.
1.3 Conformity with the Directives
This product bears the CE mark in accordance with the Directives 2014/
35/EU (Low Voltage Directive), 2014/30/EU (EMC Directive) and 2011/
65/EU (RoHS Directive).
1.4 Symbols
Symbols on the Hub
Symbols on the packaging
Product disposal symbol (see "Disposal [ → 18]").
Top
Protect from moisture

66 37 727 D3667
6D3667.208.01.02.02 09.2017
1General information Dentsply Sirona
1.4Symbols Operator's manual Hub
Fragile; handle with care
Temperature during storage and transport
Relative humidity during storage and transportation
Stack limit

66 37 727 D3667
D3667.208.01.02.02 09.2017 7
Dentsply Sirona 2Safety
Operator's manual Hub 2.1General safety information
båÖäáëÜ
2Safety
2.1 General safety information
Only use original software
Only use original software or software which has been released by
Dentsply Sirona.
Dentsply Sirona assumes no liability for the use of third-party software.
Software and software components must not be installed using incorrect
data.
Please check that each installed component has been granted approval
in its country. Contact your dealer for more information.
Changes to the unit
Modifications to this unit which may affect the safety of the operator,
patients or third parties are prohibited by law!
Do not cover ventilation openings
Ventilation openings must not be obstructed.
2.2 Electrical voltage
WARNING
Electrical voltage
➢Before commissioning, check the device and the power cable for
any damage.
➢Replace any defective power cable with an original spare part.
➢Have electrical work performed on the machine by appropriately
trained personnel only.

66 37 727 D3667
8D3667.208.01.02.02 09.2017
3System description Dentsply Sirona
3.1Scope of supply Operator's manual Hub
3System description
3.1 Scope of supply
●Hub
● Critical Ops USB Key
● LAN cable for network connection (with blue plug)
● LAN cable for service (with yellow plug)
● Power cable
3.2 Scope of functions
Hub offers the following scope of functions:
● Central storage of patient data and CEREC exposures
● Access to patient data and intraoral exposures via all devices
connected in the network (CEREC AC and PCs).
● Backup function
● Easy installation via Plug&Play
3.3 Data security
Data saved on the Hub are highly encrypted.
Each unit has an individual encryption. The data can only be read out
from the respective unit.
In order to read out data from a spare unit, the Critical Ops USB Key is
required.

66 37 727 D3667
D3667.208.01.02.02 09.2017 9
Dentsply Sirona 3System description
Operator's manual Hub 3.4Hub (hardware)
båÖäáëÜ
3.4 Hub (hardware)
A USB interfaces
B On/Off key (Standby)
C Control light
A LAN socket for service (yellow)
B LAN socket to be connected to the network (blue)
C Fan control
IMPORTANT
The fan control (C) must remain in the center position in order to
guarantee adequate cooling for the Hub.

66 37 727 D3667
10 D3667.208.01.02.02 09.2017
3System description Dentsply Sirona
3.5Critical Ops USB Key Operator's manual Hub
3.5 Critical Ops USB Key
The USB key for critical processes (Critical Ops USB Key) contains a
backup copy of the admin password and information, which can be used
to encrypt the data stored on the Hub.
All data on the hard disks of the Hub are highly encrypted, and the
corresponding encryption information are stored on the Critical Ops USB
Key. Without this information, the data stored in the Hub in the event of
hard disk failure or damage cannot be restored - including for Dentsply
Sirona. Each Critical Ops USB Key is unique and precisely fits one Hub.
3.6 Hub Control Center (Software)
The following actions are performed with the Hub Control Center:
● New Hub Setup
● Replacement Hub Configuration
● Configure Hub
● Display Notifications
3.7 Compatible CEREC software
The Hub is compatible with the following software:
● CEREC SW from Version 4.5.1
● CEREC Premium SW from Version 4.5
● CEREC Ortho SW from Version 1.2.2
3.8 System requirements
IMPORTANT
Data protection
Keep the Critical Ops USB Key in a safe or outside your practice.
Operating
system
Windows 7 or higher
Network ● LAN network
● Min. 1 GB recommended bandwidth
● All units which should be granted access to the
Hub, must be in the same subnetwork.
● For the Plug&Play installation, automatic
specification of the IP address is recommended
via DHCP.
Internet
connection
(recommended)
For automatic installation of updates and use of the
program for the purpose of quality improvements, an
Internet connection is required.
Table des matières