DEMA RAPID FIRE MODELS
6300, 6300-2, 6300-3, 6300-4 6300-5, 6310, 6300H 6300E, 6300EH, &6310E
INSTRUCTION SHEET
I-1002 Pg. 3 of 12
Rev. G-40295 11/25/14
2. INSTALLATION:
NOTE: ALL INSTALLATIONS MUST CONFORM TO LOCAL PLUMBING CODES
AND USE THE APPROVED BACKFLOW PREVENTORS.
WARNING: WATER SUPPLY PRESSURE MUST NOT EXCEED 125 PSI AND WATER
TEMPERATURE MUST NOT EXCEED 150°F (66°C). USE CARE WHEN
HANDLING HAZARDOUS CHEMICALS.
A. MOUNTING AND WATER SUPPLY:
Mount in a convenient location using the screw and anchor kit provided
The water inlet is equipped with a female garden hose fitting. The fitting may be removed to
permit direct connection to 1/4” NPT pipe.
WARNING: WATER SUPPLY PRESSURE MUST NOT EXCEED 125 PSI AND WATER
TEMPERATURE MUST NOT EXCEED 150°F (66°C).
B. OUTLET CONNECTION:
Connect the discharge hose to the brass outlet garden hose fitting and squeeze the hose clamp
around the hose. Locate the position for the mounting screw, and mount the hose clamp to the
wall using the remaining screw and anchor. Spray guns, spray nozzles or foaming wands may be
used on the hose outlet. We recommend spray nozzles of 6 GPM or higher (at 40 psi). When a
spray gun or nozzle is used, hose lengths must not exceed those shown in Table 1. Hoses, spray
guns, and foam wands are available through DEMA. See the parts list on the last page for the
various styles.
TABLE 1
Hose I.D. 3/8" 1/2" 5/8" (or larger)
Max. Length 15 ft. 50 ft. 100 ft.
C. CHEMICAL SUPPLY:
WARNING: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS.
Place the chemical container(s) in a convenient location not more than six feet below the RAPID
FIRE (greater distances will reduce injection capabilities). The top of the chemical product
container should never be higher than the RAPID FIRE. Cut vinyl tubes to any convenient length
that will allow the tubes to reach the bottom of the container(s). Remove the screw (22) and
knob (21), raise the hinged cover, and push the other tubing ends over the chemical inlet barbs
located on the sides of the injector. Place the tubing ends with the foot valves into the chemical
containers.