Replacing the gauge
Replacing the gaugeReplacing the gauge
Replacing the gauge
A special repair kit has been designed, so the
electronic unit doesn't have to be removed.
epair kit 98958080 This kit includes:
one complete gauge
six connectors
repair instruction
In order to get the best result, it is very impor-
tant that the instructions below are strictly fol-
lowed. It is also very important that a proper
tool is used.
Disconnect the bus cable.
Snap open the locks to the lid, and fold
down the lid with the electronics.
Open the meter. emove the meter cover.
emove the spoiler and the measuring cup.
Turn and remove the bayonet to the strain
gauge.
Pull out the strain gauge.
Disconnect the two connectors to the sole-
noid valve.
With the lid straight downwards, slide it to
the left to release it from the hinges.
Stretch the cable between gauge and elec-
tronic unit.
Lay the cable flat on a table and fix it with a
tape (1). Cut the cable.
Dispose of the old gauge, and place the new
gauge with the cable arranged exactly as
the old one. It is very im- portant that the
cable is oriented exactly as the old one. Do
not strip the wires.
Take one wire from the gauge cable and
corresponding wire from the electronic unit
DeLaval milk meter MM15
DeLaval milk meter MM15DeLaval milk meter MM15
DeLaval milk meter MM15
161 Preventive maintenance
8 (9)
© DeLaval 2012.All rights reserved.
Printout from Memoviewer 11/6/2012.