DanVex DEH-600wp Manuel utilisateur

DEH-600wp
DEH-1000wp
Instruction manual
Dehumidifiers for swimming pools

R
www.danvex.fi
1
Please read this instruction manual carefully and save it before using the dehumidifier. If you
have any questions about using the dehumidifier, please contact Your dealer.

R
www.danvex.fi 2
INTRODUCTION .............................................................................................................................
PRECAUTIONARY MEASURES .....................................................................................................
DESCRIPTION OF THE DEHUMIDIFIER .......................................................................................
WIRING DIAGRAMS .......................................................................................................................
INSTALLATION NOTE ....................................................................................................................
START-UP AND OPERATION (DESCRIPTION OF THE CONTROL PANEL) ................................
REMOTE CONTROL AND ERROR CODES ...................................................................................
DEHUMIDIFIER MAINTENANCE ....................................................................................................
TECHNICAL SPECIFICATIONS ......................................................................................................
WARRANTY TERMS AND WARRANTY CARD ..............................................................................
CONTENTS
3
4
6
7
8
9
11
12
13
14

R
www.danvex.fi
INTRODUCTION
MODELS:
DEH-600wp
DEH-1000wp
All the dehumidifiers described in this manual are designed to maintain the relative
humidity of indoor air in the range from 40% to 99%, at air temperature from +10°C to
+32°C.
3

R
www.danvex.fi 4
Read this manual carefully for safety before
you start operating the dehumidifier. Below are
the symbols used in this manual.
If dirt sticks to the plug of the power cord
or plug and socket connection is loose, it
may cause fire or electric shock.
PRECAUTIONARY MEASURES
CAUTION
Remove any dirt from the plug
of the power cord.
There should be no breaks in the cord
or its artificial extensions.
Do not scratch or bend the power cord.
Do not place heavy objects on the power
cord, heat it, or expose to other factors. The
cable may be damaged, which can lead to fire
or electric shock.
Consult Your dealer on installation
of the device.
Do not insert fingers or any objects
into the air intake/ outlet.
Do not attempt self-repair or re-installation
of the device.
If this is done incorrectly, it may cause fire,
electric shock, water leakage, etc.
Contact Your dealer.
Strictly forbidden
Be sure to follow the
instructions
Provide grounding
Unplug the power cord from
network
Never store anything on the
device
Electric shock hazard
Never insert fingers
or any items
Do not disconnect / do not connect
power supply during operation
If during operation there is something
unusual (burning smell, etc.), turn
off the device and disconnect it from
the network
Use grounding.
In case of incorrect operation of the device,
contact Your dealer.
Avoid contact of the grounding
wire with gas and water pipes,
lightning rod or telephone cable. If
the grounding is made incorrectly,
it can lead to defeat electric shock
hazard.

R
www.danvex.fi
5
This may cause fire or deformation.
PRECAUTIONARY MEASURES
CAUTION
Do not use insect repellent or solvents.
Before cleaning the device switch it off
and disconnect the power cable from
the mains.
It can cause a short circuit that may result
in electric shock or fire.
Do not clean the device with water.
● This can lead to electric shock.
As the fan rotates at high speed, cleaning of
operating device can cause injury.
If the device is installed in a damp
location, ensure its isolation from
moisture.
If you do not provide isolation
of the device from moisture, it may
cause electric shock.
If You do not, the device may accumulate dirt
and cause a fire.
If You are not going to use the device
during a long period, unplug it from
the mains.
Do not install the device in a place where
there is flammable gas.
Do not install the device where in unsafe
operation conditions.
Do not press the switches with wet hands.
This may cause electric shock.
Unassisted installation of the device is
forbidden.
If this is performed incorrectly, it may cause
fire, electric shock, water leakage, etc.
Please contact Your dealer or technician.
Do not pull on the power cord.

R
www.danvex.fi 6
AIR DEHUMIDIFIERS: DEH-600wp and DEH-1000wp
DEHUMIDIFIER DESCRIPTION
Power cordPower cord
Drain hose
Moist air input
Mounting bracket Dry air output Control panel

R
www.danvex.fi 7
DEH-600wp, DEH-1000wp
SINGLEPHASE (1PH/50 Hz)
WIRING DIAGRAM
Датчик
влажности Датчик температуры
воздуха
Датчик системы
разморозки
Вывод на дисплей PCB
Трансформатор
Главный контроллер PCB
Мотор
вентилятора
Компрессор
Источник питания
Main controller PCB
Humidity detector
Air temperature sensor
System defrost sensor
PCB display representation
Compressor
Fan motor
Power source
Transformer
Protection from low pressure
Protection from high pressure

R
www.danvex.fi 8
INSTALLATION NOTE
Mounting of the dehumidifier on the wall:9
Step 1: Select the correct position for mounting on the wall, depending on the size of the
holes set and the holes positions of the wall mount bracket. The place of installation should
guarantee the vertical position of the dehumidifier. Mark places for drilling.
Step 2: Use hammer drills to drill holes with depth of 8 ± 0.5 cm Then use the anchor bolts
and install them into the holes with a hammer.
Step 3: Install the wall bracket with anchor bolts in the correct position. Please, provide
secure fixing of the bracket using nuts and washers. Don't forget to hold the bracket in the
correct position during installation.
Step 4: Install the dryer on the wall bracket.
Step 5: Connect the drain hose to the dehumidifier. Turn on the dehumidifier for trial use.
Check the device for presence of abnormal vibration and noise.
Step 6: Installation is finished and the dehumidifier is ready for use.
Installation diagram.
In case of indoor installation of the device, provide availability of free space for its
maintenance. The premises, where the device is installed, must be ventilated.
Before installation of the dehumidifier:
Before shipment from the factory all the dehumidifiers are subject to tests. Unpack the box
and check for damage on the surface of the device, as well as for completeness of
components in accordance with the list specified in the instructions. If You find any damage,
do not attempt to install the humidifier and immediately contact the supplier.
IF DURING TRANSPORT THE DRYER WAS LYING ON THE SIDE, IT NEEDS
TO BE LEFT UPRIGHT FOR AT LEAST 24 HOURS BEFORE THE START OF
ITS OPERATION!!!
(failure to perform this may cause damage to the dryer and void your warranty)
CAUTION!!!

R
www.danvex.fi
9
START-UP AND OPERATION
Description
The control panel is designed to exercise the control functions over the dehumidifier
operation, change of parameters of operation and maintenance of the specified values
for these parameters. The panel consists of control buttons and LCD screen.
Buttons are used for switching on/off and changing of parameters and modes of
operation of the dehumidifier. At the top of the panel screen the current time (if
configured), and operation mode on the basis of the built-in humidity sensor, constant
operation, ventilation mode, current values of humidity and temperature, set/preset
humidity value, the status of the timers and their settings are displayed.
Designation of control buttons:
(ON/OFF) - on / off of the dehumidifier,
(UP) - increase of the parameter (humidity, time),
(DOWN) - decrease of the parameter (humidity, time),
(MODE) - Change (selection) of the operation mode (built-in humidity
sensor / external humidity sensor / constant dehumidification / ventilation
mode),
(TIME) - setting the timers and time
(TIMERSET) - selection of timer operation mode (off /once /daily)!
Names an values of parameter:
INTERNAL - activated internal / built-in humidity sensor, EXTERNAL -
activated external humidity sensor (have to be connected, in the
absence of contact, error E7 is displayed),
CURRENT HUMIDITY - current/valid humidity,
CURRENT TEMPERATURE - current/actual air temperature,
TIMER ON – time of switching on the dryer when the timer is
operating;
TIMER OFF – time of switching off the dryer when the timer is
operating;
OFF - timers are disabled,
TIME - single cycle of the timer operation;
EVERY DAY - daily mode of the timer operation.