Danfoss Link CC Manuel utilisateur

Danfoss Link™ CC Central Controller
Installation Guide
DANFOSS HEATING SOLUTIONS
MAKING MODERN LIVING POSSIBLE


VISGL45X © Danfoss 04/2011
SE
FI
NL
PL
CZ
GB
DE
FR
DK
Installation Guide Danfoss Link™ CC - Installation
Installation Guide.............................................................. 3
Installationsanleitung......................................................... 17
Guide d’installation...........................................................31
Installationsmanual...........................................................45
Installationshandbok .........................................................59
Asennusohje .................................................................73
Installatiehandleiding ........................................................87
Instrukcja instalacji ..........................................................101
Instalační příručka...........................................................115
3

VISGL45X © Danfoss 04/2011
Installation Guide Danfoss Link™ CC - Introduction
Index
Introduction Danfoss Link™ is a wireless control system for a
variety of heating systems.
The central controlling unit is the Danfoss Link™
CC (Central Controller) equipped with a colour
touch screen. From this you can control the entire
installation.
The Danfoss Link™ CC communicates wirelessly with
all other Link devices in the installation.
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Configuration
1: Adding devices to the system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2: Set country, language and date/time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3: Start up the installation menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4: Create rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5: Purpose of adding repeaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6: Adding devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7: Adding service devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8: Perform network test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
9: Finalise installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Modifying an existing Installation
1: Adding devices to an existing room. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2: Changing parameters for Heat Regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3: Removing / Resetting a device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4: Factory reset of Central Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Upgrading software version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Warnings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Disposal instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4

VISGL45X © Danfoss 04/2011
Installation Guide Danfoss Link™ CC - Installation
Installation The Danfoss Link™ wireless system’s transmission
range is sufficient for most applications; however
each building has different obstacles affecting com-
munication and maximum transmission distance.
If communication problems occur Danfoss suggests
that accessories would be required to support the
system, such as repeaters. In exceptional cases the
wireless system may not be suitable for your instal-
lation.
Please be aware of the following, when installing
Danfoss Link™ CC:
Do not install Danfoss Link™ CC,
where it will be subject to direct
sunlight.
The installation height should
typically be between 140-170 cm.
Note! Do not power the Devilink™ CC until the manual tells you to do so.
Do not remove the protective film on the touch screen, the end user should do this.
Danfoss Link™ CC can be installed with either a PSU
(in-wall power supply) or a NSU (net power supply.
Installing Danfoss Link™ CC with In-Wall PSU:
• Hold the PSU over the wall box and mark up the 4
screw holes.
Make sure the top is level.
• Drill holes and put fitting plugs in.
• Connect the PSU according to the connection
diagram on the back side.
• Mount the PSU with the 4 screws.
Installing Danfoss Link™ CC with NSU:
• Hold the mounting plate on the wall and mark up
the 4 screw holes. Make sure the top is level.
• Drill holes and put fitting plugs in.
• Mount the mounting plate with the 4 screws.
Do not mount the Danfoss Link™ CC yet!
• Connect the NSU to a power outlet.
Danfoss Link™ PSU (in-wall Power Supply)
Danfoss Link™ NSU (Net Power Supply)
GB
5

VISGL45X © Danfoss 04/2011
Installation Guide Danfoss Link™ CC - Configuration
1: Adding devices to the
system
When adding devices to the Danfoss Link system,
the distance between CC and device must not
exceed 1.5 m. To accomplish this an installation tool
is offered: Danfoss Link BSU Battery Supply Unit.
Put 10 fresh AA alkaline batteries in the BSU by slid-
ing off the lid.
Be aware of the correct battery polarity.
Slide the lid back on and attach the BSU battery
pack onto the back of the Danfoss Link™ CC. When
you are ready to do the commissioning, turn the
switch located on the BSU to the ON position.
Danfoss Link™ CC will now start up. This might take
several minutes - please be patient . . .
Note! Do not configurate the Danfoss Link™ CC until all room devices have been mounted.
2: Set country, language
and date/time
3: Start up the
installation menu
Remove the front cover of the Danfoss Link™ CC by
gently pulling it off. Press and hold the setup pin for
3 seconds to start the installer menu.
Danfoss Link can control attached devices in two
different modes:
1. Heating regulation: Control of room heating
devices - more information see Configuration 4:
Create rooms.
2. ON/OFF Functions: Scheduled ON and OFF
control of various electrical devices - more
information see Configuration 7: Adding service
devices.
1. Select Language. 2. Select Country 3. Set Date and Time
If lights up, a help text is available and provides you with a description to the process, which is in progress.
6

VISGL45X © Danfoss 04/2011
When using a wireless transmission technology, several issues have to be taken in consideration, to ensure
the best performance:
• A maximum distance of 30 m between devices in free space must not be exceeded.
• Receiving devices should be placed on opposite or next wall as the transmitter.
• All metallic parts in the building construction can reduce communication signals.
• Reinforced concrete walls and floors dampen the signal strength significantly, but almost all types of
construction materials reduce the signal more or less.
• Also corners which is a result of the design of the building, can be a hinder for the further communication
of signals, due to either a longer distance or missing reflecting opportunities.
Many mains powered devices work automatically as repeaters without being installed as a dedicated
repeater - see manual.
If necessary, devices can be configured as service device to work as dedicated repeaters - see Configura-
tion 7: Adding service devices.
Example of repeating structure
) ) ) ) ) ) ) ) ) ) ) ) )
) ) ) ) ) )
) ) ) ) ) ) ) ) ) ) ) ) )
) ) ) ) ) ) ) ) )
) ) ) ) ) ) ) ) ) ) )
Danfoss
Link™ CC
Danfoss
Link™ FT
Danfoss
Link™ HC
Danfoss
Link™ HR
Danfoss
Link™ PR Danfoss
Link™ RS
Danfoss
living
connect
Danfoss
Link™ RU
) ) ) ) ) ) ) ) ) ) ) ) )
) ) ) ) ) ) ) ) ) )
Max. 3 repeaters can be used between CC and the receiving device.
Note! Only devices with main power supply, and planned as repeaters (both normal and dedicated)
must always be configured first.
When devices are configured as repeaters, link test and network test is to be carried out to ensure the signal
quality.
Installation Guide Danfoss Link™ CC - Configuration
4: Create rooms
5: Purpose of adding
repeaters
Create all rooms in desired order before further configuration and adding of devices.
It is recommended to make a plan for the entire installation, which shows the individual placement and type
of all units in relation to room disposition. On this basis, the priority order and configuration of all devices
can be determined.
Remove the front cover and press the Set-Up pin for 3 seconds.
1. Select Rooms and Devices. 2. Select Add New Room. 3. Enter/Edit Room Name.
GB
7

VISGL45X © Danfoss 04/2011
All devices must be configured, according to the previous plan for the installation, to ensure the signal path.
Remove the front cover and press the Set-Up pin for 3 seconds.
1. Select Rooms and Devices. 2. Select Manage Existing Room. 3. Select a room..
4. Select Room devices. 5. Select Add a device. 6. Select Begin Registration.
When the first unit in relation to CC device is added, a link test must
be performed in order to ensured a successfully communication - see
manual for the individual device how this is done - but be sure that
CC is located on final destination before test is carried out.
Subsequently, the other repeaters must be added, before all remain-
ing devices are being added.
When you have completed adding all devices for the individual room,
an overview of devices associated to the room will be showed.
Press back symbol to get to the Room Devices menu, where all as-
sociated room devices are listed.
7. Press Enter.
Installation Guide Danfoss Link™ CC - Configuration
6: Adding room devices
Note! Danfoss Link™ automatically selects the regulation principle according to the types of devices in
the room. To change regulation principle, see page 10.
8

VISGL45X © Danfoss 04/2011
Installation Guide Danfoss Link™ CC - Configuration
7: Adding service devices Danfoss Link™ supports many different types of service devices with functions both like simple ON/OFF
devices for other electrically equipment, signal repeaters and controllers for hydronic systems.
Remove the front cover and press the Set-Up pin for 3 seconds.
1. Select Rooms and Devices. 2. Select Add Service Device. 3. Select Begin Registration.
4. Enter/Edit Device Name.
GB
9

VISGL45X © Danfoss 04/2011
After finishing installation, a network test have to be performed, to
ensure, that communication between all added devices and Central
Controller is stable.
Do not perform the network test before CC is mounted at final desti-
nation.
Turn off the battery pack and place the Danfoss Link™ CC on the
previously installed mounting plate. The CC will now power up again
and show you a screen like this.If there is uncertainty about the
network’s performance, it is advisable to perform a network test before
the installation is completed entirely.
Remove the front cover and press the Set-Up pin for 3 seconds.
1. Select Status and Diagnostics. 2. Select Network. 3. Select Start Network Test.
At the end of the network test the CC awaits for all battery operated devices to wake up and report.
To speed up the process to fulfil the network test, you may press any button on the battery operated
devices to force them to report immediately.
Installation Guide Danfoss Link™ CC - Configuration
8: Perform network test
9: Finalise installation Press the Set-Up pin to close the installa tion.
10
Autres manuels pour Link CC
2
Ce manuel convient aux modèles suivants
1
Table des matières
Langues :
Autres manuels Danfoss Routeur réseau
Manuels Routeur réseau populaires d'autres marques

NETGEAR
NETGEAR FS526T - Switch Manuel utilisateur

Korenix
Korenix JetNet 5710G Series Manuel utilisateur

Automated Logic
Automated Logic ZN551 Manuel du propriétaire

Cisco
Cisco ASR 1000 Series Manuel de l'opérateur

EnGenius
EnGenius ESR-9710 Manuel utilisateur

Cisco
Cisco 805 Series Instructions d'utilisation et de sécurité