Daikin BRC2E52C7 Manuel utilisateur

Be sure to read this installation manual before
conducting the installation of this product.
WIRED REMOTE
CONTROLLER
INSTALLATION MANUAL
BRC2E52C7
BRC3E52C7

Installation manual BRC2E52C7 / BRC3E52C7
14P368041-1 – 2014.02
Contents
Contents
1. Safety Precautions............................................. 2
2. Accessories ........................................................ 4
3. Remote controller installation procedure........ 4
4. Functions and menu items of the
remote controller buttons ............................. 10
5. Power-on........................................................... 12
6. Field settings .................................................... 15
7. Test operation method (SkyAir only) ............. 19
8. Checking procedure of Error History............. 23
9. Registration method of the
Maintenance Contact information ................ 24
10. Conrmation of registered details ............... 25
11. Clock & Calendar ........................................... 26
12. Language ........................................................ 27
13. Prohibit Buttons ............................................. 28
14. Function Prohibition ...................................... 30
15. Prohibit Mode ................................................. 31
16. External Input Interlock Function ................. 33
17. Single and Dual setpoint mode .................... 39
18. Other Service Settings .................................. 40
19. Software update with Updater ...................... 42

BRC2E52C7 / BRC3E52C7 Installation manual
4P368041-1 – 2014.02 2
Safety Precautions
1. Safety Precautions
The original instructions are written in English. All other languages are translations of the original
instructions.
Also see the installation manual attached to the indoor unit.
Please read these Safety Precautions carefully before installing the remote controller.
● This manual classies the precautions into WARNING and CAUTION. They both contain important
information regarding safety. Be sure to follow all the precautions below.
WARNING Failure to follow these instructions properly may result in personal
injury or loss of life.
CAUTION Failure to observe these instructions properly may result in property
damage or personal injury, which may be serious depending on the
circumstances.
● After completing the installation, conduct a trial operation to check for faults and explain to the
customer how to operate the air conditioner with the aid of the operation manual. Ask the customer
to store the installation manual along with the operation manual for future reference.
WARNING
Ask your dealer or qualied personnel to carry out installation work.
Do not attempt to install the remote controller yourself. Improper installation may result in water
leakage, electric shocks or re.
Consult your local dealer regarding relocation and reinstallation of the remote controller.
Improper installation work may result in leakage, electric shocks or re hazards.
Install the remote controller in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or re.
Be sure to use only the specied accessories and parts for installation work.
Failure to use the specied parts may result in the unit falling down, water leakage, electric shocks
or re.
Install the remote controller on a foundation strong enough to withstand the weight of the remote
controller.
Insufcient strength may result in the remote controller falling down and causing injury.
Electrical work must be performed in accordance with the relevant local and national regulations and
with the instructions in this installation manual.
Be sure to use a dedicated power supply circuit only. Insufcient power circuit capacity and improper
workmanship may result in electric shocks or re.
Always perform installation work with the power turned off.
Touching electric parts may result in electric shock.
Do not disassemble, reconstruct or repair.
This may result in electric shock and/or re.
Make sure that all wiring is secured, the specied wires are used and that there is no strain on the
terminal connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or re.
The choice of materials and installations must comply with the applicable national and international
standards.

Installation manual BRC2E52C7 / BRC3E52C7
34P368041-1 – 2014.02
Safety Precautions
CAUTION
To avoid leakage and electric shock due to entry of water or insects, ll the wiring through hole with
putty.
To avoid electric shocks, do not operate with wet hands.
Do not wash the remote controller with water, as this may result in electric shocks or re.
Install the indoor and outdoor units, power cord and connection wires at least 1 meter away from
televisions or radios to prevent interference and noise.
(Depending on the incoming signal strength, a distance of 1 meter may not be sufcient to eliminate
noise.)
Do not install the air conditioner in the following locations:
1. Where there is a high concentration of mineral oil spray or vapour (e.g. a kitchen).
Plastic parts may deteriorate and fall off which could result in water leakage.
2. Where corrosive gas, such as sulphurous acid gas, is produced.
Corroding of copper pipes or soldered parts may result in refrigerant leakage.
3. Near machinery emitting electromagnetic radiation.
Electromagnetic radiation may disturb the operation of the control system and result in
malfunctioning of the unit.
4. Where ammable gas may leak, where there is carbon bre or ignitable dust suspensions in
the air or where volatile ammables such as paint thinner or gasoline are handled.
Operating the unit in such conditions may result in re.
5. High temperature areas or direct ames.
Overheating and/or re may occur.
6. Moist areas or places which may be exposed to water.
If water enters the remote controller, electric shock may be caused and the inner electronics
may fail.
When the thermostat function of the remote controller is used, select the installation location while
considering it should be a place:
● Where the average temperature in the room can be detected.
● Which is not exposed to direct sunlight.
● Which is not near a heat source.
● Which is not affected by the outside air or air draught due to, for example, opening/closing of
doors, the air outlet of the indoor unit or the like.

BRC2E52C7 / BRC3E52C7 Installation manual
4P368041-1 – 2014.02 4
Accessories
2. Accessories
The following accessories are included.
Wood screw +
wall plugs Small screw Clamp Wiring retainer
(Ø3.5×16) (M4×16)
2x
2x
2x
1x
1x
3. Remote controller installation
procedure
3-1 Determine where to install the remote controller.
Make sure to follow "1. Safety Precautions" when determining the location.
3-2 Make a wiring through hole on the wall if the wires are
coming out from the rear.
Set the center of the wall hole
to the center of the wiring
through hole on the controller
lower case when making the
hole.
40
48.5
Lower case
Through hole
Ø 8-10
Through
hole
External view of the remote controller
Ø 8-10
If the hole size is too large or the location is not
proper, the hole may come out from the
controller.
CAUTION

Installation manual BRC2E52C7 / BRC3E52C7
54P368041-1 – 2014.02
Remote controller installation procedure
3-3 Determine the direction of the controller wiring outlet (rear
outlet, left outlet, top left outlet, top center outlet).
3-3-1 Rear outlet 3-3-2 Left outlet
Cut off the resin area (hatched area). Cut off the thin area (hatched area) with
nippers or the like and then remove the burrs
with a le or the like.
3-3-3 Top left outlet 3-3-4 Top center outlet
Cut off the thin area (hatched area) with
nippers or the like and then remove the burrs
with a le or the like.
Cut off the thin area (hatched area) with
nippers or the like and then remove the burrs
with a le or the like.
3-4 Conduct wiring.
1. The switchbox and the transmission wiring should not be attached.
2. Do not directly touch the remote controller PCB.
CAUTION
Wiring Specications
Wiring Type Sheathed vinyl cord or cable
Wiring Size 0.75~1.25 mm²
Wiring Length Max. 500 m(*)
*This is the total length in the system when using group control.

BRC2E52C7 / BRC3E52C7 Installation manual
4P368041-1 – 2014.02 6
Remote controller installation procedure
The sheath part in the remote controller case should be stripped following these instructions.
For easy wiring, it is better to
keep ±10 mm difference
between the length of the two
wires.
±10 mm
Cutting guideline
of the wiring
Peel the shield and sheath
Sheath stripping length:
● ±150 mm for top left outlet
● ±200 mm for top center outlet
Connect the terminals (P/P1, N/P2) of the remote controller to the terminals (P1, P2) of the
indoor unit. (P1 and P2 have no polarities.)
3-4-1 Rear outlet
Secure the wiring at
the wiring fixing point
by using the attached
clamp.
Clamp
-Cross-section
Wiring fixing
point
Clamp
PCB
Upper case
P2
Indoor unit
P1
Lower case
<Wiring fixing guideline>

Installation manual BRC2E52C7 / BRC3E52C7
74P368041-1 – 2014.02
Remote controller installation procedure
3-4-2 Left outlet
P2P1
Indoor unit
Upper case
Lower case
PCB
3-4-3 Top left outlet
Install the attached
wiring retainer to
prevent wiring
pinching as shown
to the left .
P2P1
-Cross-section
Wiring
Upper case
Lower case
Upper case
Wiring retainer
Wiring retainer
Indoor unit
PCB
3-4-4 Upper center outlet
PCB
P2P1
Lower case
Upper case
Wiring retainer
Indoor unit

BRC2E52C7 / BRC3E52C7 Installation manual
4P368041-1 – 2014.02 8
Remote controller installation procedure
● Do not perform wiring close to a power line in order to avoid electrical noise (external
noise).
● Seal the wiring draw-in port securely with putty (eld supply) to prevent the entry of
insects or the like.
CAUTION
3-5 Fixing procedure of the lower case.
In the case of wiring a remote controller through the top center outlet or rear outlet, perform the
wiring through the outlet hole in the lower case before it is installed on the wall.
3-5-1 Wall mounting
Secure by using the attached wood screws (2×).
Wood screws
(
Ø 3.5×16)
3-5-2 Switchbox mounting
Secure by using the attached small screws (2×).
(Installation pitch)
46
84
Switchbox for two units
(with no cover)
Switchbox
(field supply)
(Use optional accessory
KJB211A)
Small screws (M4×16)

Installation manual BRC2E52C7 / BRC3E52C7
94P368041-1 – 2014.02
Remote controller installation procedure
(Installation pitch)
28
84
Switchbox for one unit
(with no cover)
Small screws (M4×16)
Switchbox
(field supply)
(Use optional accessory
KJB111A)
● Select a at surface for installation if possible.
● Do not tighten the installation screws too much to avoid deforming the lower case.
CAUTION
3-6 Attach the upper case.
● Align the upper case with the tabs of the lower case (6 points) and insert the upper case.
● Be careful not to pinch the wiring when attaching.
● Peel off the protective seal which is attached to the upper case.
3-7 Remove the upper case.
Insert a slot screwdriver into the slots in the lower case (2 places) to remove the upper case.
● The remote controller PCB is installed on
the upper case. Be careful not to damage
the PCB with the slot screwdriver.
● Take care that dust or moisture does not
touch the PCB of the removed upper
case.
NOTE
Insert and twist the screwdriver
lightly to remove the upper case.
Screwdriver
Lower case
Upper case
Autres manuels pour BRC2E52C7
2
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Daikin Routeur réseau
Manuels Routeur réseau populaires d'autres marques

NETGEAR
NETGEAR FS526T - Switch Manuel utilisateur

Korenix
Korenix JetNet 5710G Series Manuel utilisateur

Automated Logic
Automated Logic ZN551 Manuel du propriétaire

Cisco
Cisco ASR 1000 Series Manuel de l'opérateur

EnGenius
EnGenius ESR-9710 Manuel utilisateur

Cisco
Cisco 805 Series Instructions d'utilisation et de sécurité