CTR KILL-BACT Manuel utilisateur

OPERATING MANUAL
Rev. 1 – 04/2011
Ultrasonic Nebulizer
KILL-BACT
COD. 4018150
CTR S.R.L.
Via T. ed E. Manzini, 9 – 43126 Parma – Italy
Tel: +39-0521.957611 – Fax: +39-0521.957677
Internet: http://www.ctrgroup.it; e-mail: info@ctrgroup.it

2 OPERATING MANUAL
No parts of this manual may be reproduced in any form without prior written consent by the manufacturer.
The manufacturer reserves the right to make improvements or changes in its instruments at any time and without
prior notice.
Other product names and companies mentioned in this document may be registered trademarks registered by the
respective owners.
Rev. 1 – 04/2011
IMPORTANT !
We recommend you thouroughly read the instructions provided in this manual
before switching on the device.
This will enable you to obtain excellent performance and reliability over time.
Store this manual close to the device for quick reference by operators!
The Manufacturer shall not be liable for failures or other consequences deriving
from incorrect procedures on the part of the User.

OPERATING MANUAL 3
Dear Customer,
Congratulations on purchasing our KILL-BACT COD. 4018150 ultrasonic nebulizer, a very modern
instrument which will help you clean the interior of any vehicle.
The technology applied and the quality achieved in years of experience in the sector, have made
KILL-BACT COD. 4018150 an excellent instrument which will give you maximum satisfaction
thanks to its efficiency and reliability over time.
The device uses the latest technology in the field of ultrasonic nebulization.
This manual is to be considered an integral part of the instrument as it contains general
instructions for correct use of the device.
We therefore invite you to carefully read through the instructions before switching on the device, to
adequately train operators and to store the manual for future reference. These good practices shall
ensure that you obtain from the instrument top performance and reliability over time.

INDEX 4 OPERATING MANUAL
INDEX
Manufacturer’s CE Declaration of Conformity............................................................................5
1 INTRODUCTION ....................................................................................................................6
2 SAFETY PRECAUTIONS.......................................................................................................7
2.1 For the device......................................................................................................................7
2.2 For the user..........................................................................................................................8
2.3 Correct Disposal of product (WEEE Directive).....................................................................8
3 TECHNICAL CHARACTERISTICS.........................................................................................9
3.1 General................................................................................................................................9
4 PREPARATION FOR USE ...................................................................................................10
4.1 Content of package............................................................................................................10
4.2 Leds description.................................................................................................................11
4.3 Preparing the device..........................................................................................................12
5 USE ..................................................................................................................................13
6 MAINTENANCE....................................................................................................................16

OPERATING MANUAL 5 DECLARATION OF CONFORMITY
Declaration of Compliance CE
Under the machinery directive 2006/42/CE, annex II letter. A
The Manufacturer
CTR S.R.L.
Via T. ed E. Manzini, 43126 PARMA - ITALY
Tel: +39-0521.957611 – Fax: +39-0521.957677
Declare under its sole responsibility that the product;
Ultrasonic Nebulizer
Model KILL-BACT - Code 4018150
Complies all the provisions of Machinery directive 2006/42/CE, plus the directives:
·
2006/95/EC (LVD)
·
2004/108/EC (EMCD)
·
2002/95/EC (ROHS)
·
2002/96/EC (WEEE)
The manufacturer declare that the technical manufacturing documentation is available at the
company.

INTRODUCTION 6 OPERATING MANUAL
1 INTRODUCTION
KILL-BACT COD. 4018150 is a modern, advanced ultrasonic nebulizer with compact dimensions
and possibility of multiple applications.
The device is designed for the nebulization of its specific BACTERICIDAL liquid COD. 6026010
and the application of this on the air conditioning system of vehicles (cars, trucks, buses, etcetera)
to achieve sanitizing of seat upholstering seat and mats, and to sterilize the systems.
The liquid is nebulized into small particles (5 µm) and is conveyed into the system to be
disinfected, through a specific shaped tube.
Some of the main advantages of the ultrasonic nebulization mechanism are:
no formation of condensate and effective sanification/disinfection due to the particular
characteristics of the product’s particles, obtained by ultrasonic nebulization.
The liquid particles completely sanitize the conditioning system (including ducts and fans), to stop
the spreading of bacteria and germs and eliminate unpleasant smells inside the vehicle.
For best results, we recommend you carry out a treatment with KILL-BACT COD. 4018150 at
least twice a year.

OPERATING MANUAL 7 SAFETY PRECAUTIONS
2 SAFETY PRECAUTIONS
2.1 For the device
•Before each use, check the device, and the supply cable. Do not use the device if the cable
is damaged. Any damage must be repaired by qualified personnel.
•Store the device is a dry place, sheltered from the weather.
•The device is not suitable for operation in environments with risk of explosion or fire.
•Ensure that the power supply connection points comply with current safety regulations
(differential switch and grounding).
•Use exclusively the COD. 6015010 BACTERICIDAL liquid.
•Place the supply cable in a position where it will not create an obstacle and where it will not
be stepped on. Do not use extension cables. The device must be positioned in a place where
it will not come into contact with wet areas or anything else which could affect its insulation.
•Opening of the instrument by unauthorized personnel is prohibited.
•Maintenance or repair operations must be carried out by authorized personnel.
WARNING
If used correctly and in accordance with the instructions provided by the Manufacturer this
instrument present no hazard for operators.
The Manufacturer shall not be liable for failures and other consequences deriving from
incorrect operations on the part of operators.

SAFETY PRECAUTIONS 8 OPERATING MANUAL
2.2 For the user
•Carefully read though this operation manual before switching on power.
•The instrument must be used only by qualified, trained personnel.
•Use only the cable supplied with the instrument.
•After the treatment ventilate the interior for approx. 5 – 10 minutes.
2.3 Correct Disposal of product (WEEE Directive)
•To prevent possible harm to the environment or human health from uncontrolled waste
disposal, pleased separate this from other types of wastes and recycle it responsibly to
promote the suistainable reuse of material resources.
•Household users should contact either the retailer where they purchased this product, or their
local government office, for details of where and how they can take this item for
environmentally safe recycling.
ATTENTION
The mark following indicates that it should not be disposed, with other household
wastes at the end of its working life.

OPERATING MANUAL 9 SAFETY PRECAUTIONS
3 TECHNICAL CHARACTERISTICS
3.1 General
Power supply:
230 Vac 50/60 Hz
Absorbed current:
Approx. 0,15 Ampere
Dimensions:
L= 295 mm, H = 220 mm, P = 150 mm
Weight:
~3,1 Kg
nebulized liquid:
Circa 15 ml/min
Noise level:
< 70 dBA
Operating temperature:
0° ÷+60°C
Storage temperature:
–30° ÷+90°C

USE 10 OPERATING MANUAL
4 PREPARATION FOR USE
4.1 Content of package
The KILL-BACT COD. 4018150 ultrasonic nebulizer comes in a can which contains the following
material:
1. Ultrasonic nebulizer
2. Operating Manual
3. Conveyor Tube
4. Supply cable
You can purchase the COD. 6026010 BACTERICIDAL liquid from your local
dealer.
IMPORTANT
Ensure that all the parts listed are contained in the case, if any parts are missing
or damaged contained your local dealer.
NOTE
We recommend you do not dispose of the packaging,
because it will provide protection if you need to transport the device.
1
2
3
4
Ce manuel convient aux modèles suivants
1
Table des matières