On/Off Switch:
Pressing power button can switch between on and off mode. Fan coil unit and valve will be turned off
when power off the thermostat.
Cool/Heat/Ventilation Mode Switch:
When power on, press”
M
”to switch, is cool mode, is heat mode, is
ventilation mode
Temperature Setting:
When power on, Press
and to adjust temperature. Temperature will go up/down 0.5
℃
per
press
Fan Operation:
•
Under Cool/Heat Mode:
4 fan modes available: auto , High , Medium , Low . Press to choose
•
Fan Only Mode:
3 fan modes available: High , Medium , Low . Press to choose
*Notes:Low fan speed is the default mode when power on thermostat each time to avoid high setup current and save energy. 3 seconds later, fan will run as setting
Clock and Timing Switch Setting:
•
Clock setting:
Press till “mm”is shining, then press
∧
or
∨
to adjust minute; press again till “hh”is shining, then
press
∧
or
∨
to adjust hour; press once more weekdays icon shining, and press
∧
or
∨
to adjust
weekdays
•
Timing Switch:
When thermostat powers on, press shortly till “hh
:
mm”
、
“”
、
“ON” show. If “”“ON” are shining, press
∧
or
∨
to set timing on(30 mins change for per press); If “”“Off”are shining, press
∧
or
∨
to set timing off(30 mins change
for per press). The setting is valid for one day.
How to cancel timing on/off:
When thermostat powers on, press shortly till “hh
:
mm”
、
“”
、
“ON” show. If “”
“ON” are shining, press
∧
or
∨
to “00:00”to cancel timing on. Same for timing off.
Keypad lock
•
Keypad lock:
when the function is on, the keypad will be locked after 30 seconds of no operation.
•
Keypad unlock :
press for 5 seconds to unlock the keypad
Keycard Contact
If the thermostat with keycard contact, the icon will show on the LCD display under unoccupied mode. When keycard is
pulled out, the unoccupied mode is set up, shows. If under cool mode, temperature will be automatically set at 26
℃
with low fan speed; if under heat mode, temperature will be automatically set at 18
℃
with low fan speed. Buttons
∧
and
∨
are disable until keycard is inserted.
Timer Operation
Power on thermostat, press for 5s to enter timer function. The time showing is the cumulative running time of the
thermostat
Power on thermostat, press for 5s, and then press to reset timer
Freezing protection mode
When thermostat is power-off and the ambient temperature is below 5
℃
, thermostat will automatically enter heat
mode and the will be founded on the display, valve will be opened as well as the high speed fan. The thermostat
automatically turns off the output once the ambient temperature goes up to 7
℃