Runner Quick Programming Guide Pg-1 of 2
Installer Code: 000000,Master Code: 123, Siren Time 5min,
Exit Delay 60 Sec, EntryZ1 20 Sec, Runner-16 Zones 1-8
Enabled (2K2), Runner-8 Zone 1-4 Enabled (2K2)
UserCodes - 1 to100
User PIN Numbers& Remotes
STAY Arm Zones - ArmedinSTAY mode
Press 6 to turn off light 6
24 HourZones
Handover DelayZones(Musthave anEntryDelay)
Instant Zones - ProgramEntry Delay as 0 seconds
P 122 E 1 E 6 Off E
P 122 E 16 E 6 Off E
Press 3 to turn On light 3
P 123 E 1 E 3 On E
P 123 E 16 E 3 On E
Press 1 to turn On light 1
P 123 E 1 E 1 On E
P 123 E 16 E 1 On E
Zones
Enable Wireless Zones - Default = FreeWave (Type-3)
Wireless Zones
Press 5 to turn On light 5
P 122 E 1 E 5 On E
P 122 E 16 E 5 On E
1st, Press & Hold-in Tamperon Device.2nd,EnterLocationto Enrol Device
P 164 E 1 E E
P 164 E 16 E E
Release Device Tamper to Enrol
Release Device Tamper to Enrol
Installer Code4to 6Digits
Code
P 25 E 1 E E
-To Report Arm/ Disarm, Turn ON - 1 and Turn OFF - 3.
-To Report STAYArm/ Disarm, Turn ON - 2 and Turn OFF - 4.
-To Report DisarmOnly AFTER an Alarm, Turn ON- 3 and Turn OFF - 1.
-To Report STAY Mode DisarmOnly AFTER an Alarm,Turn ON - 4 and Turn OFF - 2.
-To Report Full Arm/ Disarm+ STAY Arm/Disarm, Turn ON - 1 & 2 and Turn OFF - 3 & 4.
-To Report DisarmOnly AFTER an Alarmand STAY Mode DisarmOnly AFTER an Alarm,
Turn ON - 3 & 4 and Turn OFF - 1 & 2.
SettingOpen& ClosingReports - PerPhone Number
P 188 E 1 E 1 2
P 188 E 2 E 1 2
34 E
3 4 E
1 = Sunday2 = Monday,
If Daylight Saving settingsare required please see programming manual
Telephone Numbers - Back To Base OR Domestic Dial
DiallerOption- Enable DiallingFunctions
ClientIDAccount Number- 4 digit account code
Entry Delay Timer- PerZone 0 - 9999 seconds
Setting TheSystemClock
P 26 E 1 E 24h
Time E
P 26 E 2 E Day 1-7 E
DD / MM/ YY
P 26 E 3 E DDMM
YY E
SystemTimersEntry& Exit
Z1 Entrytime in seconds
P 144 E 1 E Sec’s E
P 144 E 16 E Sec’s E Z16 Entrytime in seconds
Instant Zone = 0 Seconds
Stay Entry Delay Timer- PerZone 0 - 9999 seconds
Z1 Entrytime in seconds
P 145 E 1 E Sec’s E
P 145 E 16 E Sec’s E Z16 Entrytime in seconds
Instant Zone = 0 Seconds
P 60 E 1 E Sec’s E
Exit Delay Timer- global Area-Atime 0 - 255 seconds
P 61 E 1 E Sec’s E
STAYExit Delay Timer- global Area-Atime 0 - 255 sec.
Dialler Programming
MakeSure 1 & 6 On
P 175 E 1 E 1&6
On E
1st Phone Number
P 181 E 1 E Ph # E
2nd Phone Number
P 181 E 2 E Ph # E
Back to Base A/C #P 62 E 1 E AC # E
When enabling Domestic Dial at this location, all dialing defaults get set to report zone
alarms & panics only. No systemreporting is sent e.g. lowbattery, Open/Close, etc.
Domestic DiallingDefault
SetsPh# 1 to DomesticDialP 182 E 1 E 2 E
SetsPh# 2 to DomesticDialP 182 E 2 E 2 E
Time BetweenTest Report Back toBase (Hours)
Test Report Back toBase Time of DAY
P 175 E 4 E 24h
Time E 24Hr Time to send test report
Hours
P 175 E 5 E E 24 = Daily, 168 = Weekly
Entering Installer Programming Mode
P 0 0 0 0 0 0 E
P 1 E 1 E PIN# E
P 1 E 100 E PIN# E
Wireless Remote Buttons CanBe Users - 21 to100 (total 80)
Default forWireless Blk Remote Users 61-100(Runner V:9.08ABrds*)
PresetsFortheNew(smaller) Type9F (916MHz) BlackRemotes(RemoteUser’s61- 100) ;
User 61 = Off, User 62 = On, User 63 = StayOn / Off,
User 64 = AuxO/P 4*(Garage Door), User 65 = Dualpush (Instant) PANIC, ……
User 96 = Off, User 97 = On, User 98 = StayOn / Off,.
User 99 = AuxO/P 4*(Garage Door), User 100 = Dualpush (Instant) PANIC.
Default forWireless Blue Remote Users 41-60(Runner V:9.08ABrds*)
PresetsFortheOlder Type4F(433MHz) BlueRemotes(RemoteUser’s41- 60) ;
User 41 = On / Off, User 42 = StayOn / Off, User 43 = Dualpush (Instant) PANIC,
User 44 = AuxO/P 4*(Garage Door), …….. User 57 = On / Off,
User 58 = StayOn / Off, User 59 = Dualpush (Instant) PANIC,
User 60 = AuxO/P 4*(Garage Door).
*= AuxOutput-4(to operateGarageDoor) isOnly availableon Runner-16 & Runner-Plus
panels. On theRunner-Lite(Runner-8) panel, the4xOutput RelayExpanderMUSTbeused.
Default = Radio Users
flash strobe on Arm(1x)
& Disarm(2x)
Press Remote
Button
P 18 E 21 E E
P 18 E 100 E Press Remote
Button
E
P 50 E 1 E 1 ON E
P 52 E 1 E 1 ON E
For Siren ArmChirp
For Siren Disarm Chirp
Remote Control ARM / DISARM SirenChirps (Area-’A’)
Enrolling Wireless Zones - Default = FreeWave9F
Default Usertype forUsers 1-40 = PIN orProx