Crosswater Elite Manuel utilisateur

Elite water
control system
Operation and care guide
DIGITAL
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
DIGITAL
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
This operation and care guide
must be left with the user.
ELITEUSER

1
DIGITAL
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
Important Safety Information
Please read these instructions carefully before
using this system and keep in a safe place for
future reference.
To reduce the risk of electric shock and injury,
basic safety precautions, including the following,
should always be followed when using electrical
appliances.
Children MUST be supervised at all times when
using this shower control. Training should be
given to children and vulnerable individuals
before permitting them to operate the controls.
Do not pull on the power cable: this may
damage it and cause electric shock.
Never operate any appliance with a damaged
cable or plug. Do not use an appliance that
has been dropped or damaged or after any
malfunctions.
WARNING
CONTINUOUSLY TURNING THE
CONTROL WHEEL IN THE CLOCKWISE
DIRECTION MAY OVERRIDE THE PRE-
SET MAXIMUM TEMPERATURE, WITH
CONSEQUENT RISK OF SCALDING.
ALWAYS TAKE CARE WHEN
OPERATING THE CONTROL WHEEL,
AND DO NOT LEAVE CHILDREN
UNATTENDED WHILST THE PRODUCT
IS IN OPERATION.

Key to the display icons
Operating the Elite water control system
Setting the temperature
Setting the water flow
Using the menu
Diverting the water flow
Accessing the extended menu display
Setting the memory
(shower processor only)
Bath filling memory option
(bath processor only)
Cleaning (safe) mode
Opening and closing the pop up
bath waste (*using Viega electronic
waste filler)
Self check mode
Thermal disinfection
2
Contents
3
4
4
5
5
6
6
7
8
9
9
10
10
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
Extra features
Changing display from flow
to temperature
Water consumption
Return
Setting maximum inlet temperature
Setting maximum run-time
(until automatic switch-o)
Change from Centigrade (Celsius)
to Fahrenheit
Statistics
Reset to factory settings
Cleaning / maintenance
Servicing / contact info
11
11
11
11
12
12
12
13
13
15
15

3
DIGITAL
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
Key to the display icons
Open / close bath drain
valve (Bath filler waste only
available on bath processor)
Cleaning mode: disables the
control for 45 seconds
Set a new code
Backwards / return
Divert: Bath processor
Outlet 1: bath filler icon
Outlet 2: hand shower icon
Outlet 3: fixed head icon
Change display: flow to
temperature - Display
switches automatically back to
temperature after 10 seconds
Save / delete current
pre-sets / quick access
(flow, temperature, filling
bath stop level
Statistics
Self check: Diagnosis:
Inspection of control unit and
water supply
Setting maximum run-time
(until automatic switch-o)
Setting the maximum outlet
temperature
Change from Centigrade
(Celsius) to Fahrenheit
Reset to factory settings
Access and lock to extended
menu / features with a 3 digit
code
Shows the total amount
and last usage of water
consumption
Thermal disinfection
(emergency stop by pressing
control) Water will flow at
maximum temperature for
5 minutes
Divert: Shower processor
Outlet 1: fixed head icon
Outlet 2: hand shower icon
Outlet 3: body jet icon

4
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
Operating the Elite water control system
Setting the temperature
Turn the control wheel
anti-clockwise, the control
will illuminate Blue, the
temperature is displayed and
the light will flash until the set
temperature is reached.
Turn the control wheel until the
control illuminates Orange, the
temperature is displayed and
the light will flash until the set
temperature is reached.
Cold Warm Hot
Press the control wheel once,
the control illuminates Orange
and water will start to flow
through ‘default’ outlet.
To turn ON To turn OFF
Press the control wheel once,
the water and lights will turn o.
Important note: Risk of scalding, please read the Safety Information on page 1 before using.
Note: The ‘default outlet’ is the outlet that the water flows through
first when the control is turned on.
The default outlet is set during installation and can only be
changed from the processor, not the controller.
Turn the control wheel
clockwise, the control will
illuminate Red, the temperature
is displayed and the light will
flash until the set temperature
is reached. After 40 degrees
is reached, one full turn of the
wheel will equal a half degree.

5
DIGITAL
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
Setting the water flow
At the same time, press
and turn the control wheel
clockwise to increase the flow
and anti-clockwise to decrease
the flow.
Turn on the control.
Press the menu button and the
option icons will appear.
Rotate the control wheel to
scroll through the icons, when
the required icon is highlighted
press the menu button to
select.
Using the menu (Note: The bath control is used below for demo purposes)

6
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
Diverting the water flow
Accessing the extended menu display
Without turning on the control,
press the menu button and
scroll to the ‘open lock’ icon,
press menu button to select.
The pre-set key code is 000,
this can be changed using the
control wheel as required.
Note: The key icon will have a
question mark above it until it
has been selected or changed.
Press the menu button to
select and the key code will
be displayed, press again and
the display briefly shows if the
extended menu is locked
(a cross) or open (a tick), the
display then closes.
Note: The icon to set a new
code will be activated for 30
minutes each time the control
is turned on, after that the icon
will not show.
Next time the menu is entered
the extended menu can be
viewed.
To ‘lock’ the extended menu
follow the same procedure,
except select the ‘locked’ icon.
Turn on the control.
Press the menu button, the icons
will appear with the ‘un-selected’
outlet icon highlighted.
Press the menu button to select,
the outlet will be diverted, the
temperature will be displayed and
the outlet icon will appear briefly.
Note: The icons only represent a
divert function (images only).
If outlet 3 is selected when the
unit is switched o there will
always be a slight surge of water
through outlet 2 as it’s making its
way back to outlet 1.

7
DIGITAL
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
Setting the memory (shower processor only)
Up to three memory settings
can be stored.
Note: Only the ‘default outlet’
temperature can be set to
memory. The max. temp setting
for the memory is 40 degrees.
Press the control wheel
once. The temperature will
be displayed along with the
memory number (1, 2 or 3)
next to the temperature icon.
Set the desired
temperature.
Set the flow rate.
Press the menu button,
scroll to the ‘save’ icon.
Press the control wheel
once and the shower
temperature is now stored.
To access a stored memory;
Whilst in the ‘O’ position,
press the control wheel once
to select memory 1, press twice
for memory 2 and press three
times for memory 3.
The screen will display the
selected memory setting.
1
2
3
4
5

8
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
Bath filling memory option (bath processor only)
Up to three memory settings
can be stored.
Note: To fill the bath from one
of the memory settings the
bath must be connected to the
‘default outlet’. The max. temp
setting for the bath memory is
42 degrees.
Press the control wheel
once. The bath will start to
fill. The temperature will be
displayed along with the
memory number (1, 2 or 3)
next to the temperature icon.
Fill to the desired
temperature and depth.
Press the menu button,
scroll to the ‘save’ icon.
Press the control wheel
once and bath temperature
and depth is now stored.
To access a stored memory;
Whilst in the ‘O’ position,
press the control wheel once
to select memory 1, press twice
for memory 2 and press three
times for memory 3.
The screen will display the
selected memory setting.
1
2
4
3

9
DIGITAL
DIGITAL WATER CONTROL AT YOUR FINGERTIPS
Opening and closing pop up bath waste (bath processor only)
This option is only available if
using a *Viega DGX0600C
and DGX0700C drain valve.
(works with Bath processor
only.)
Press the menu button and
select the ‘pop up waste’ icon.
Press the control wheel once
to open or close the pop up
waste.
The icon will display briefly to
confirm.
Press the menu button and
enter the extended menu.
Select the ‘cleaning mode’
icon by pressing the menu
button.
The control will flash Green.
This will disable the controls
for 45 seconds to allow the
controls to be cleaned without
accidentally turning on the
control.
Cleaning (safe) mode
To stop, press the menu button,
scroll to the power icon and
press the menu button.
Table des matières
Autres manuels Crosswater Système de contrôle