Cover JR 10 Manuel utilisateur

V.2051
Uninterruptible power supply UPS
COVER JR
10 –15 –20 kVA
3:3 / 3:1
User Manual
The content of this document is the copyright of the publisher
and may not be reproduced without prior permission.
The right to modify the design and specifications is reserved without
prior notice.
Copyright 2020
COMEX S.A.
All rights reserved.

Table of contents
1. Safety rules.......................................................................................................................................1
2. Transport, unpacking the UPS .........................................................................................................3
3. Appearance and connection............................................................................................................4
3.1. UPS rear panel..........................................................................................................................4
3.2. Connection of the remote REPO switch....................................................................................4
3.3. Connecting communication to the External Service Bypass EMBS. .........................................4
3.4. Connection of communication options.....................................................................................5
3.5. Power connection - configuration 3:3 ......................................................................................5
3.6. Power connection - configuration 3:1 ......................................................................................5
4. LCD display operation ......................................................................................................................6
4.1. Main display window ................................................................................................................6
4.2. UPS control window..................................................................................................................7
4.3. Measure window.......................................................................................................................9
4.4. UPS configuration window (Setting) .......................................................................................11
4.5. Information window................................................................................................................13
4.6. Alarm window .........................................................................................................................13
5. Audible alarms and event codes....................................................................................................14
5.1. Audible alarms.........................................................................................................................14
5.2. Warning codes.........................................................................................................................14
6. UPS operations...............................................................................................................................15
6.1. Turn on the UPS from the mains.............................................................................................15
6.2. UPS shutdown .........................................................................................................................15
6.3. Turn on the UPS from the battery ..........................................................................................15
6.4. Switching UPS to the Maintenance Bypass mode ..................................................................16
6.5. Switching the UPS from Maintenance Bypass mode..............................................................16
6.6. Installing the software.............................................................................................................16
6.7. Working conditions .................................................................................................................16
6.8. The storage conditions............................................................................................................17
6.9. Battery change ........................................................................................................................17

1
1. Safety rules
This manual provides information on the safe use of the UPS. Before unpacking and installing the UPS,
read its contents and follow its instructions.
FULFILLED STANDARDS - EXECUTION
EN 62040-3
Uninterruptible Power Systems (UPS): Methods for determining
the properties and test requirements.
FULFILLED STANDARDS - ELECTROMAGNETIC COMPATIBILITY
EN 62040-2 :2006 C3
Guaranteed Power Systems (UPS): Electromagnetic Compatibility.
EN 61000-2-2 :2002
Electromagnetic Compatibility (EMC): Environment. Compatibility
levels for conducted low-frequency disorders and signaling in
public low-voltage power systems.
EN 61000-4-2 :2009
Electromagnetic Compatibility (EMC): Testing and measurement
methods - electrostatic discharge immunity test.
EN 61000-4-3 :2006
+A1 :2008 +A2 :2010
Electromagnetic Compatibility (EMC): Testing and measurement
methods - Radio frequency electromagnetic field immunity test.
EN 61000-4-4 :2004
+A1 :2010
Electromagnetic Compatibility (EMC): Testing and Measurement
Methods - Testing of immunity to a series of fast electrical
transients.
EN 61000-4-5 :2006
Electromagnetic Compatibility (EMC): Testing and Measurement
Methods - Surge Immunity Test.
EN 61000-4-6 :2009
Electromagnetic Compatibility (EMC): Test and Measurement
Methods - Immunity to conducted disturbances, induced by radio
frequency fields.
EN 61000-4-8 :2010
Electromagnetic Compatibility (EMC): Testing and measurement
methods - Testing of resistance to magnetic field at the frequency
of the power grid.
The device complies with the Directive 2004/108 / EC (EMC).
FULFILLED STANDARDS - SAFETY
EN 62040-1:2008
Uninterruptible Power Systems (UPS): General requirements and
requirements for UPS safety.
EN 60950-1:2006
Information technology devices. Security.
IEC 60417
Symbols used on devices
The device complies with the 2006/95 / EC (LVD) directive.
警告
危险
警告
危险
警告
危险

2
Keep these operating instructions! The manual contains important instructions on the use of the
UPS that should be followed during installation and use of the UPS device and batteries.
Condensation may occur if the power supply is cold and is brought into a warm place. Therefore,
you should wait at least 2 hours until it starts up.
To reduce the risk of electric shock, the UPS should be installed in a pollution-free room with
adequate temperature and humidity. The ambient temperature must not exceed 40 ° C.
Do not install the power supply in a place exposed to direct sunlight or other heat sources.
Do not connect devices that can overload the UPS output, e.g. laser printers, electric heaters, etc.
Cables should be connected and arranged in such a way that no one can accidentally step on or
disconnect them.
The UPS must be connected to a wall outlet with a working protective earth (GND).
Do not block the ventilation openings on the UPS. Make sure the vents are exposed and there is a
minimum of 25cm free space for ventilation.
The UPS power socket should be protected with an appropriate overcurrent switch.
The UPS has its own battery power source, so there may be voltage at the output sockets even
though the UPS is not connected to the mains.
Battery service should be performed by trained personnel who are knowledgeable about battery
operation and take appropriate precautions during its use.
If it is necessary to replace the battery, use batteries with the same number and parameters, i.e.
rated voltage, capacity and dimensions.
ATTENTION! Do not throw batteries into fire. The battery may explode.
ATTENTION! Do not open or mutilate the battery. Released electrolyte is harmful to the
skin and eyes. It can be toxic.
The battery can present a risk of electric shock. The following precautions should be taken when
working with batteries:
oRemove watches, wedding rings and other metal objects from your hand.
oUse tools with insulated handles.
oWear rubber gloves and boots.
oDo not lay tools or metal parts on top of the battery.
oDisconnect the battery charging source before connecting or disconnecting the battery
terminals.
Make sure the battery is not inadvertently grounded. If present, remove the source of ground fault.
Contact with any part of a grounded battery can result in electric shock.

3
2. Transport, unpacking the UPS
Check carefully that the carton and the contents are not damaged. If any damage is found,
immediately inform the shipping company and the power supply distributor.
Do not throw away the UPS packaging.
1. If no damage is found, carefully open the carton.
2. Unpack all protective elements (sponges, fillers).
3. Gently remove the UPS from the protective film and place it on a clean, flat and stable surface.
To prevent mechanical damage, shock and impact, only ship the UPS in its original
packaging.

4
3. Appearance and connection
3.1. UPS rear panel
1. RS 232 Port.
2. USB Port.
3. EPO port (fire protection switch connector).
4. Parallel port (optional).
5. Parallel port (optional).
6. Communication card slot (SNMP).
7. External battery socket.
8. Rectifier power disconnect switch for UPS.
9. Mechanical and service bypass.
10. Power cable connection strip.
11. Terminals for powering the UPS rectifier.
12. Terminals for connecting load power.
13. Ground terminal.
14. Ground terminal.
15. Internal bypass feeder disconnector of UPS.
16. Bypass power supply terminals.
17. Output disconnector.
18. Bypass communication connector ext. EMBS.
Fig. 1 UPS COVER JR 10 - 20K
3.2. Connection of the remote REPO switch
The UPS is equipped with an EPO port for connecting the Remote Emergency Power Off (REPO) switch.
The EPO port is configured as NC (normally closed), the activation of EPO occurs by breaking the
connection between Pin 1 and Pin 2 (removal of the jumper).
3.3. Connecting communication to the External Service Bypass EMBS.
The UPS is equipped with an EMBS connector, enabling communication to be connected to the
External Service Bypass, in order to enable the inverter to be turned off while operating on the External
Bypass. It is an NC (normally closed) port that is activated by breaking the connection between Pin 1
and Pin 2 (removing the jumper). Activating the port turns off the inverter and blocks the possibility
of its activation.

5
3.4. Connection of communication options.
The UPS has two communication ports:
USB
Intelligent Slot (SNMP)
To enable automatic management and monitoring of the UPS, connect the USB cable supplied with
the UPS, on one side to the USB socket on the UPS and on the other side to the USB socket on the
computer. The software provided with the UPS allows you to automate the processes of turning on /
off the receivers connected to the UPS depending on the events that occur on the UPS (e.g. power
failure, low battery level, overload, etc.). The software also allows for ongoing monitoring and logging
of UPS event history.
The UPS also has a slot for additional cards, which enables retrofitting with an SNMP network card for
remote communication via the network.
3.5. Power connection - configuration 3:3
NOTE: UPS operation configuration may only be changed by an authorized service!
Fig. 2 Terminal for connecting the power supply for COVER JR 10 - 20K configuration 3: 3 phase
3.6. Power connection - configuration 3:1
NOTE: UPS operation configuration may only be changed by an authorized service!
Fig. 3 Power supply terminal for COVER JR 10 - 20K configuration 3: 1 phase

6
4. LCD display operation
The PSU is equipped with a color LCD touch panel. Below is a diagram showing the possibilities and
the location of the various information available in the display menu.
For 3: 3 and 3: 1 UPS configurations there are differences in the number of displayed output phases
and bypass phases.
The screens below show a 3: 3 configuration. For a 3: 1 configuration, only 1 Output Phase and Bypass
are displayed.
4.1. Main display window

7
The main menu of the display shows the current operating mode of the UPS (energy flow through
individual functional blocks) and the parameters of power supply, batteries and UPS outputs.
To return to the main window from anywhere else, use the icon .
4.2. UPS control window
Control menu allows you to turn the UPS inverter on or off, run a battery test and silence the
audible alarm.
Select the UPS ON / OFF command to enable or disable the UPS inverter. The display will switch to the
following view asking you to confirm or cancel your selection.
Click "YES" to turn on / off the UPS. The display will return to the main window view.
Click "BACK" or "No" to return to the control window.
The display in the main window will show messages related to turning the UPS on (Turning on) or
turning off the UPS (Turning off).

8
Turn on UPS Turn off UPS
To start the battery test, select the "BATT TEST" command and confirm your selection with the "YES"
key.
To cancel the test, select the return to the "Back" menu or the "No" command.
The display in the main window will show messages related to Battery testing or Battery test failed.
Turn on battery test Turn off battery test
To silence the audible alarm, select the "MUTE ALL" command and confirm your selection with the
"YES" key.
To turn mute off, choose "Back" or with the command "No".
The mute icon appears on the display in the main window in the upper left corner .
Mute alarm Cancel mute alarm
The control menu also allows you to switch the battery charger on or off. Selecting the "ON / OFF
CHARGER" command enables it to turn on "Turn on Charger" if it is not working, or to turn it "Turn off
Charger" if it is currently active.
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Cover UPS
Manuels UPS populaires d'autres marques

Pylontech
Pylontech Victron & Pylontech US5000 Manuel utilisateur

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manuel utilisateur

Mecer
Mecer ME-1000-WTU Manuel utilisateur

Mustek
Mustek PowerMust 530(B) Plus Manuel d'installation et d'exploitation

Emerson
Emerson Liebert NXL series Manuel utilisateur

MAKELSAN
MAKELSAN BOXER SERIES Manuel utilisateur