Cooper Bussmann 1050E-T Manuel utilisateur

Read and
Retain for
Future
Reference
Cooper Bussmann
1050E-T
Unmanaged Ethernet Switch
User Manual
Version 1.1.5

2www.cooperbussmann.com/wirelessresources
Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual
Rev 1.1.5
Interference Issues
This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a
commercial or industrial installation. This equipment generates, uses, and can radiate radio frequency energy. It
may cause harmful interference to radio communications if the equipment is not installed and used in accordance
with the instructions.
UL Listed Models
When operating at elevated temperature extremes, the surface may exceed +75 Celsius. For user safety, the
1050E-T should be installed in a restricted access location. The openings on the enclosure are for air convection.
Protect the equipment from overheating. DO NOT COVER THE OPENINGS.
UL Notice
The Equipment shall be powered using an external Listed Power Supply with LPS outputs or a Class 2 Power
Supply. The 1050E-T must be properly grounded for surge protection before use.
Hazardous Location Notices
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations only.
For Hazardous Locations operating temperature is strictly -40˚C to +60˚C only.
WARNING: EXPLOSION HAZARD
Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous.
WARNING: EXPLOSION HAZARD
Substitution of any components may impair suitability for Class I, Division 2.
WARNING: EXPLOSION HAZARD
The area must be known to be non-hazardous before servicing/replacing the unit and before installing.
WARNING
Exposure to some chemicals may degrade the sealing properties of materials used in the Sealed Relay Device.
Recommendations
It is recommended to inspect the sealed relay device periodically and to check for any degradation of the materials
and to replace the complete product, not the sealed device, if any degradation is found.
Important Notice
Cooper Bussmann reserves the right to modify the equipment, its specification or this manual without prior notice,
in the interest of improving performance, reliability, or servicing. At the time of publication all data is correct for the
operation of the equipment at the voltage and/or temperature referred to. Performance data indicates typical values
related to the particular product.
No part of this documentation or information supplied may be divulged to any third party without the express
written consent of Cooper Bussmann. Products offered may contain software which is proprietary to Cooper
Bussmann. The offer or supply of these products and services does not include or infer any transfer of ownership.
Release Notice
This is the May 2013 release of the 1050E-T Unmanaged Ethernet Switch User Manual version 1.1.5.

www.cooperbussmann.com/wirelessresources
Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual
3Rev 1.1.5
Follow Instructions
Read this entire manual and all other publications pertaining to the work to be performed before installing, oper-
ating, or servicing this equipment. Practice all plant and safety instructions and precautions. Failure to follow the
instructions can cause personal injury and/or property damage.
Proper Use
Any unauthorized modifications to or use of this equipment outside its specified mechanical, electrical, or other
operating limits may cause personal injury and/or property damage, including damage to the equipment. Any such
unauthorized modifications: (1) constitute “misuse” and/or “negligence” within the meaning of the product warranty,
thereby excluding warranty coverage for any resulting damage; and (2) invalidate product certifications or listings.

4www.cooperbussmann.com/wirelessresources
Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual
Rev 1.1.5
Chapter 1 - INTRODUCTION ...................5
1.1 Module Identification ....................5
1.2 Features and Benefits....................6
1.3 General Specifications ...................6
1.4 Mechanical Specifications ................7
1.5 Order Information .......................7
Chapter 2 - GETTING STARTED ................8
2.1 Package Contents ......................8
2.2 Hardware Description ....................8
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Top View ..............................8
2.3 Wiring ................................9
Wiring the Power Inputs ..................9
Wiring the Fault Alarm Contact ............9
Grounding ............................10
2.4 LED Indications, Ports, and Cabling. . . . . . . .10
LED Indicators ........................10
Ports ................................10
Cabling ..............................11
2.5 Mounting Installation ...................11
DIN-rail Mounting ......................11
Wall Mount Plate Mounting ..............12
Appendix A - GLOSSARY ....................13
CONTENTS

www.cooperbussmann.com/wirelessresources
Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual
5Rev 1.1.5
ChapTEr 1 - INTrODUCTION
The 1050E-T Ethernet Switch from Cooper Bussmann is a cost-effective solution that meets the high
reliability requirements demanded by industrial applications. The 1050E-T is a 5-port 10/100TX Slim Type Industrial
Unmanaged Switch that includes the following features.
High-Speed Transmissions
The Industrial Switch includes a switch controller that can automatically sense transmission speeds (10/100Mbps).
The RJ-45 interface can also be auto-detected, so MDI or MDIX is automatically selected and a crossover cable is
not required. All Ethernet ports have memory buffers that support the store-and-forward mechanism. This assures
that data is properly transmitted.
Dual Power Input
To reduce the risk of power failure, the Industrial Switch provides +12 Vdc to +48 Vdc dual power inputs. If there is
power failure, Industrial Switch will automatically switch to the secondary power input.
Flexible Mounting
The Industrial Switch is extremely compact and can be mounted on a DIN-rail or a wall so it is suitable for any
space-constrained environment.
Advanced Protection
The power line of the 1050E-T supports up to 3,000 Vdc EFT (Electrical Fast Transient) protection, which secures
equipment against unregulated voltage and makes systems safer and more reliable. Its 6,000 V ESD protection for
Ethernet ports makes the 1050E-T suitable for harsh environments.
Wide Operating Temperature
The operating temperature of the 1050E-T is between -40°C and 75°C. Given this wide range, you can use the
Industrial Switch in some of the harshest industrial environments.
Easy Troubleshooting
LED indicators make troubleshooting quick and easy. Each 10/100 Base-TX port has 2 LEDs that display the link
status, transmission speed and collision status. Also the three power indicators P1, P2 and Fault help you diagnose
problems immediately.
1.1 Module Identification
The module identification label can be found on the bottom of your 1050E-T device. This label contains the model
number, temperature range, power range, serial number, and all certifications.

6www.cooperbussmann.com/wirelessresources
Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual
Rev 1.1.5
1.2 Features and Benefits
• IEEE 802.3 10Base-T, 802.3u 100Base-TX
• Flow control on full duplex
• RJ-45 connectors with auto MDI/MDIX functionality
• Store-and-forward switching architecture
• Relay alarm contact for system events
• UL Class I Division II for Group A,B,C, and D hazardous locations
• Supports surge protection 3,000 Vdc for power line
• Supports 6,000 Vdc Ethernet ESD protection
• Supports redundant +12 Vdc to +48 Vdc power input
• Provides flexible mounting: DIN-rail, Wall Mounting
• Supports operating temperatures from -40°C to 75°C
1.3 General Specifications
Product specifications are subject to change without notice.
Ethernet Standards/Transfer
Rate
Standards 10Base-T Ethernet (IEEE 802.3)
100Base-TX Ethernet (IEEE 802.3u)
Flow Control and Backpressure (IEEE 802.3x)
Transfer Rate 10 Mbps (IEEE 802.3)
100 Mbps with Auto-Negotiation (IEEE 802.3u)
Fault Alarm Fault Alarm Contact Alarm for System Events
1 Relay Output, 1A MAX @ 24 Vdc or 24 Vac
Ethernet Port Connectors RJ-45
Network Cabling 10Base-T: 2-pair UTP/STP Cat. 3,4,5,6 cable EIA/TIA-568 100-ohm
(100m/328)
100Base-TX: 2 pair UTP/STP Cat. 5,6 cable EIA/TIA-568 100-ohm
(100m/328)
Protocols/Configuration Protocols Supported Multiple Access Protocol – Carrier sense multiple access with
collision detection (CSMA/CD)
User Configuration N/A
LED Indication/Diagnostics LED Indication Power OK; Fault Condition Exists
Port LED Indication Link Active, Full Duplex/Collision
Network Management N/A
Compliance EMI and EMC FCC Part 15 – Class A; CE EN61000-4-2 (ESD),
CE EN61000-4-3 (RS), CE EN61000-4-4 (EFT),
CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS),
CE EN61000-4-8, CE EN61000-4-11,
CE EN61000-4-12, CE EN61000-6-2, CE EN61000-6-4
Hazardous Area UL Class I, Division 2
Maximum Ambient Temperature +60˚C
Safety CE/EN60950-1
UL UL Listed

www.cooperbussmann.com/wirelessresources
Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual
7Rev 1.1.5
General Size 30 mm x 95 mm x 140 mm (1.18” x 3.74” x 5.51”)
Housing Painted Metal Case; IP30
Mounting DIN Rail or Wall-mount
Terminal Blocks Removable; Max conductor 12 AWG (2.5 sqmm)
Temperature Rating -40°C to +75°C (-40°F to 167°F)
Humidity Rating 5% - 95% RH Non-condensing
Weight 0.43 kg (0.95 lb)
Power Supply Nominal Supply 12 Vdc to 48 Vdc; Under/Over Voltage Protection and Reverse
Polarity
Maximum Current
Draw
450 mA
1.4 Mechanical Specifications
The following diagram shows the exterior dimensions of the 1050E-T Ethernet switch.
1.5 Order Information
Item Product Code Description
Ethernet Switch 1050E-T Basic Ethernet Switch
Power Supply PS-DINAC-24DC-OK AC/DC Adapter, 24 Vdc, 2.5 A, 60 W, -20 to +70°C

8www.cooperbussmann.com/wirelessresources
Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual
Rev 1.1.5
ChapTEr 2 - GETTING STarTED
2.1 Package Contents
• 1050E-T Ethernet Switch x 1
• Pluggable Terminal Block x 1
• Wall Mounting Plate x 2
2.2 Hardware Description
Front Panel
The front panel of the 5-port 10/100BaseTX Industrial Switch is shown below.
Top View
The top panel of the 5-port 10/100BaseTX Industrial Switch is equipped with one terminal block connector of two
power inputs.

www.cooperbussmann.com/wirelessresources
Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual
9Rev 1.1.5
2.3 Wiring
Wiring the Power Inputs
Follow these steps to insert the power wire.
1. Insert the positive and negative wires into the V+ and V- contacts on the terminal block connector.
2. When using a single power supply to power the device, connect the power supply to both power inputs to
ensure that the fault alarm is not set. (Connect V+ to both pins 2 and 6, and then connect V- to both pins 1
and 5.)
3. Tighten the wire-clamp screws to prevent the wires from coming loose.
Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of terminal block connector, as shown below. The contact will be closed for
normal operation, and will open in the case of a power failure from either of the two power inputs.
1. Insert the wires into the fault alarm contact (number 3 and 4).
NOTE The wire gauge for the terminal block should be in the range between 12 and 24 AWG.

10 www.cooperbussmann.com/wirelessresources
Cooper Bussmann 1050E-T Unmanaged Ethernet Switch User Manual
Rev 1.1.5
Grounding
To provide maximum surge and lightning protection, the 1050E-T should be effectively grounded via a GND screw
located on the top of the unit next to the terminal connector block. All ground (earth) wiring should be minimum
14 AWG.
2.4 LED Indications, Ports, and Cabling
LED Indicators
Three LEDs display the power status, and an additional ten LEDs display the network status. These LEDs are
located on the front panel of the switch and are described in the following table.
LED Color Description
P1 Green On Power input 1 is active
Off Power input 1 is inactive
P2 Green On Power input 2 is active
Off Power input 2 is inactive
Fault Red On Power input 1 or 2 is inactive
Off Power input 1 and 2 are both functional, or no power inputs
Link/Active
(1~5)
Green On Connected to network
Flashing Networking is active
Off Not connected to network
Duplex/Collision
(1~5)
Orange On Ethernet port full duplex
Flashing Collision of packets occurs
Off Ethernet port half duplex or not connect to network
Ports
Table des matières
Autres manuels Cooper Bussmann Routeur réseau
Manuels Routeur réseau populaires d'autres marques

NETGEAR
NETGEAR FS526T - Switch Manuel utilisateur

Korenix
Korenix JetNet 5710G Series Manuel utilisateur

Automated Logic
Automated Logic ZN551 Manuel du propriétaire

Cisco
Cisco ASR 1000 Series Manuel de l'opérateur

EnGenius
EnGenius ESR-9710 Manuel utilisateur

Cisco
Cisco 805 Series Instructions d'utilisation et de sécurité