Conlan Mykey CP1000 Manuel utilisateur

secure open
Conlan ApS • Speditorvej 2A • DK-9000 Aalborg • Tel: +45 72 40 60 03 • Fax: +45 96 32 00 22
www.conlan.eu • [email protected]
Code & Proximity
CP1000
Mykey - Art. No: 480015 (black), 480016 (white)
Classic - Art. No.: 482015 (black), 482016 (white)
User manual
CP1000_usermanual_ENGjan17

2
Table of contents
1. Introduction
2. Installation
3. Programming users
3.1 User positions
3.2 Programming user codes
3.3 Programming proximity tags
3.4 Programming codes/proximity tags for
special functions
3.5 Smart reading
4. CongurationofCP1000
4.1 Service code
4.2 Congurationoverview
4.3 Change Master code
4.4 Change Service code
4.5 LED indications
4.6 Outputs
4.7 Special settings
5. One-time-/day code
6. Blocking
7. Manual reset
8. Technicalspecications
9. Connection examples
page 3
page 3
page 4
page 4
page 4
page 5
page 6
page 6
page 7
page 7
page 7
page 7
page 8
page 8
page 9
page 10
page 11
page 12
page 12
page 12
page 13

3
1. Introduction
CP1000isaexiblekeypadandproximityreaderinoneunitformaydierentapplica-
tions.
In standby the yellow LED is lit (● ○ ○)
By correct code/tag lights the yellow and green LED (●● ○)
By incorrect code/tag lights the red LED (○ ○ ●)
CP1000 has a buzzer for indicating while keying, correct code/tag, incorrect etc. and
2 transistor outputs, independant from each other, so the CP1000 can give access by
code and proximity tag.
The CP1000 is a stand alone unit, that can be programmed directly by Master code
and Service code.
2. Installation
Mountthereaderonaevensurface(usethefollowingdrilltemplateforpreciset-
ting).
Connect the wires to power supply, door strike, assembly board etc.
Note: Right after applying the voltage all LED’s lights and the buzzer sounds do not
touch the reader untill the yellow LED is lit and the buzzer is silent.
See connection examples og page 13.
9 - 25 VDC / 30 mA
0V GND
Output 2 open collector, 500 mA, 0V active
External controlling green LED, 0V active
Output 1 open collector 500 mA, 0V active
External buzzer / high security
External controlling red LED, 0V active
REX, 0V active
CT 2000 Prox
ALARM SYSTEM A/S
Prox
1 3
5
7 9
2
4 6
8
0

3. Programming users
Programming the CP1000 is simple and easy to understand.
3.1 User positions
CP1000 has 200 positions, which can contain a code or a proximity tag. The positions
are divided as following:
User position Function
1 - 100 Activates output 2 (the code in position 1 is 1234 - factory default).
101 - 150 Activates output 1.
151 - 190 Activates output 1 and 2.
191 - 200 Reserved for special functions.
3.2 Programming user codes
The Master code is used to program/change/delete the users. By default the Master
code is 4711.
LED indication: No light: ○ Light: ● Flash: * Clear buer:
New users
(4711 - standard) ○ ● ○ ●● ○ ●● ○ ○ ● ○
To program more users, continue for “Key in the user positions” or press
to leave the programming mode. ● ○ ○
Changing user codes
It’s the same procedure as programming new users, just overwrite the user positions.
#
Key in the
Master code #
Key in the
user position #
Key in the
user code
#
4

5
Delete specic users
(4711 - standard) ○ ● ○ ●● ○ ○ ● ○ ● ○ ○
Delete all users
(4711 - standard) ○ ● ○ ○ ○ ●
○ ●
● ○ ○
3.2 Programming proximity tags
CP1000 can reader Atmel and Emarine tags.
Programming a new proximity tag
(4711 - standard) ○ ● ○ ●● ○ ●● ○ ○ ● ○
For more proximity tags, continue from “Key in the user position or press
to leave the programming mode. ● ○ ○
Changing proximity tags
It’s the same procedure as programming new users, just overwrite the user position.
Delete a specic proximity tag
(4711 - standard) ○ ● ○ ●● ○ ○ ● ○ ● ○ ○
#
Key in the
Master code #
Key in the
user positions ##
#
Key in the
Master code #
Key in
2500 #
#
Key in the
Master code #
Key in the
user position #
Show
proximity tag
#
#
Key in the
Master code #
Key in the
user position #
#

6
3.4 Programming codes/proximity tags for special functions
Programming the codes and proximity tags is described in 3.2 and 3.3. This entry acti-
vates the output(s) for 5 seconds (factory default). Only 1 user can enter at the time.
Programming the same user twice
By programming the same code/proximity tag on the same position twice toggles the
output.
(Ie. the code/proximity tag is entered to unlock a door and entered to lock it again).
Programming the same user 3 times
By programming the same code/proximity tag on the same position 3 times, the out-
put is designated as switch on only.
(Ie. the code/proximity tag is permanently unlocked when the code/proximity tag is en-
tered).
Programming the same user 4 times
By programming the same code/proximity tag on the same position 4 times, the out-
putisdesignatedasswitchoonly.
(Ie. the door is locked when the code/proximity tag is entered).
3.5 Smart reading
This position makes it possible to program codes/proximity tags quickier without
entering new user positions. Key in a user position and it counts automatically to the
next position. Codes and proximity tags can be programmed alternatively as you see
t.
○ ● ○ *● ○ * ○ ○ For more
codes/tags
repeat from
here
Note: This programming mode overwrites existing user positions.
#
Key in the
Master code #
Key in
05 #
Key in the start
position #
Key in the code
or show tag

7
4.CongurationofCP1000
4.1 Service code
The Service code is used for CP1000’s advanced settings such as changing the MAster
code and Service code, LED indications and much more. the overview of the settings
and the factory settings can be seen in 4.2 Conguration overview.
The Service code is 12347890 (factory default).
Note: Before the Service code can be used must the voltage be turned OFF and
ON (the Service code can now be entered within 10 seconds).
After entering the Service code the reader is in programming mode (the green LED is
lit). Each time a setting is made the CP1000 goes back to the previous point and the
next setting can be made.
The navigation is by entering the position / value followed by #.
4.2Congurationoverview
Position Setting Factory default
00 Master code (1 to 8 digits) 4711
01 Service code (1 to 8 digits) 12347890
02 LED indications Normal = Yellow, active = Yellow and green
03 Outputs Output time for 1 and 2 is 5 seconds
04 Special functions
05 Smart reading
06 Background light
07 Onetime-/day code
2500 Alle codes/proximity tags on the user positions are deleted
0250 Reset to factory default
4.3 Change the Master code
By default the Master code is 4711 and can only be used to program, change or delete
users on CP1000.
To change the Master code, enter the following:
○ ● ○ ●● ○ ○ ● ○
#
Key in the
Service code #
Key in
00 #
Key in a new
code or show tag

4.4 Change the Service code
TheServicecodeisusedtoconguratetheCP1000’ssettings.
To change the Service code, enter the following within 10 seconds after power on:
○ ● ○ ●● ○ ** ○ ○ ● ○
4.5 LED indications
The CP1000’s 3 LED’s can be adjusted at will.
To adjust the LED indications enter the following:
adjust the LED’s for standby indication (normal).
adjust the LED’s for correct code/tag indication (active).
adjust the keying indication (how the LED will react while keying).
To adjust the LED’s press on the following:
= yellow LED (toggle by press)
= green LED (toggle by press)
= red LED (toggle by press)
= buzzer (works only on active and keying indication( toggle by press))
= save and go one step back
To save the settings press or press / . to go back to the previous
point (not saving).
#
Key in the
Service code #
Key in
01 #
Key in a new
code or show tag #
Repeat new
code/tag
#
02
#
1
#
2
#
3
1
2
3
0
#
8
***
***
***
***
#*

4.6 Outputs
The CP1000 has 2 transistor outputs, which both are activated for 5 seconds (factory
default) when a correct code/proximity tag is entered. The output activations time can
be changed and inverted.
To change these settings key in:
activation time for output 1 (white core)
activation time for output 2 (yellow core)
The time is set as:
● ○ ○ ○ ● ○ ○ ○ ●
If no value is entered in hours, minutes or seconds is the value automatically 0 (which
corresponds to set the output as toggle).
bonding the positions and output 1
bonding the positions and output 2
Bothoutputsarebondedtospecicpositions.Byfactorydefaultpositions1to100
and bonded to output 2 and positions 101 to 150 to output 1.
The value can not be crossed.
inverted outputs
output 1 (● ○ ○ = inverted / ○ ○ ○ = not inverted)
output 2 (○ ● ○ = inverted / ○ ○ ○ = not inverted)
To save the settings press or press / . to go back to the previous
point (not saving).
9
#
03
#
1
#
2
○ ●●
#
Key in hours
0 to 60 #
Key in minutes
0 to 60 #
Key in seconds
0 to 60
#
3
#
4
#
5
1
2
#*

4.7 Special functions
These settings is used to change the CP1000’s special functions such as turning the
buzzeron/o,enableHighSecurityetc.
To change these settings, key in:
= Service code without timeout (●= inactive / ●= active)
= The Master code can be changed by Master code (●= inactive / ●= active)
= Mute reader (●=o/●= on)
= Brown core function (●= external buzzer / ●=HighSecurity)
=HighSecurity(●= inaktiv / ●= aktiv)
= Bell/star key (●=deletesnon-nishedcodes/●= activates output 1*)
*When the bell/star key is set to activate output 1 can codes and proximity tags only activates out-
put 1.
High Security
HighSecurityincreasestheCP1000’ssecuritybyensuring2positionshavetobeacti-
vated before the output is activated (the positions must be next to each other).
Special positions
On positions 191 to 194 special functions can be activated by code/proximity tag. The
programming is like programming a new user.
191 = No buzzer.
192=Input1(browncore)function(HighSecurityorexternalbuzzer).
193=HighSecurity.
194 = Bell/star key function (activates output 2 by press).
To save the settings press or press / . to go back to the previous
point (not saving).
Note: A power cut puts the functions back to the settings made by the Service code.
10
#
04
●○ ○
1
2
3
4
5
6
#*
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Conlan Clavier

Conlan
Conlan C1000LP Manuel utilisateur

Conlan
Conlan CB 1200 Manuel utilisateur

Conlan
Conlan CB1200 490030 Manuel utilisateur

Conlan
Conlan CT1000 Manuel utilisateur

Conlan
Conlan CT 1000 Manuel utilisateur

Conlan
Conlan CM1000 Manuel utilisateur

Conlan
Conlan CT2000 Manuel utilisateur

Conlan
Conlan CT2000 Manuel utilisateur

Conlan
Conlan C1000 Manuel utilisateur