ComAp Smart Home Manuel utilisateur

Smart heating solution
Comap Smart Home
Installation manual

2 3
• Read these instructions carefully before installation
• Must be installed by a trained and experienced technician
• Make sure you have turned o the power before doing
anything
Precautions

4 5
3x AAA batteries
19.5
COMPATIBILITY INSTALLATION
The new smart thermostat solution from COMAP is compatible
with most heating systems.
On/O
contact
Control
wire
Gas heating
Oil heating
Wood heating
Heat pump
Electric heating (dry contact)
Electric heating (control wire)
Check your compatibility at www.comapsmarthome.com
CONTENTS OF THE PACKAGE
Screws and dowels
1x thermostat
1x RJ45 cable
1x USB cable
1x heating module 1x gateway
The thermostat
is attached to the
wall in a living area
(e.g. the living room)
The three devices communicate with each other via radio waves (868MHz). The maximum
distance between the gateway, the module(s) and the thermostat depends on the structure
of your home (thickness of walls and building materials used) and the radio environment
(presence of high-voltage power lines, overhead wires, devices that transmit radio waves). As
an indication: in a new building in an urban environment, a distance of 30 m can be achieved.
Connect the
gateway
to the modem
The heating module
is connected to the
heating system
1 2 3

6 7
19.5
If there is a disconnection problem, bring the thermostat within 10 cm of the
heating module and then restart the thermostat.
In the event of communication problems:
• Disconnect the gateway from the modem and reconnect it; the two gateway LEDs
must be permanently lit.
• Remove the heating module from the holder and put it back; the right and le
LEDs must be lit.
If the thermostat is no longer paired with the heating module, contact Customer
Service.
1
2
3
ERROR CODES
19.5
1
Problem with pairing
2
Communication problem
3
Disconnection
STARTING UP
Welcome Heating
command
Stop
command
Room
temperature
Setpoint
temperature Heating o Heating in
progress
LED display
Heat indicator
Activation zone
Arrows
OPERATION BUTTONS
19.5
You can activate the product
by tapping the activation area
The setpoint temperature
can be set using the
arrows
DURING INSTALLATION
Updating, please be patient. Pairing with the module Restart
THERMOSTAT

8 9
19.5
RECOMMENDATIONS
FOR INSTALLATION
INSTALLATION
Make sure that the thermostat is installed in a living area.
Where do you install the COMAP Smart Home thermostat?
• In an occupied room, usually in the living room
• Do not install against an outside wall or in draughty spaces
• Between 1.2 and 1.5 m from the ground
• Keep away from doors, wall cupboards or other objects that may interfere with the
presence detection sensor.
• Place the thermostat in a place where it cannot be exposed to direct sunlight.
• If you have pets, place the thermostat away from furniture they can sit on so that they
are not detected by the presence detection sensor.
Recommended locations
Connect the gateway to the modem using the two cables supplied.
Note: If the modem does not have a
USB port, you can connect the gateway
to the mains using a 5V DC USB charger
/ minimum 200mA (not supplied).
Connect the gateway
Both LEDs on the gateway should light up:
• The power light on the le indicates that the gateway
is being powered
• The communication light on the right indicates that there
is a good internet connection.
1

10 11
19.5
Remove the battery protection tab
on the thermostat
A symbol indicating that the product
is starting up correctly will then
appear on the thermostat display.
2
GAS, OIL, WOOD, HEAT PUMP, ELECTRIC (ON/OFF CONTACT)
Replacing a wired thermostat........................................................................ 12
Replacing a wireless thermostat or 1st installation................................... 16
ELECTRICAL VERSION (CONTROL WIRE) ............................................................ 19
The following steps depend on the heating system:
Switch o the general power supply to the housing in order to avoid any risk of electrocution.
Switch off the power
3

12 13
Heating module Thermostat
Water radiator Phase (L)
Neutral (N)
Water radiator
Water radiator
Boiler
(or stove or
heat pump)
19.5
19.5
LS
TA
LR
N
Gateway
30 m
max.
GAS, OIL, WOOD, HEAT PUMP,
ELECTRIC (ON/OFF CONTACT)
INSTALLATION WITH ON/OFF CONTACT
Replacing a wired thermostat with 2-3 wires or first installation
Input 220V
Wires usually blue
(N) and brown (L/P)
Example: Connection block of the heating module
Room thermostat
Wires usually red
or yellow
Note: Some thermostats are connected to
an input other than the one listed above
(eBus or EMS, for example). In this case, identify
the thermostat input TA, LS-LR or RT24.
To install it, open the protective cover of your water heater (using the manual if
necessary). Find the terminal block of the room thermostat.
Connect terminals L (phase) and N (neutral) of the heating module to terminals L
and N of the boiler or the terminal box. This will supply power to the heating module.
Check the stripping distances of the cables and wires.
Connect the terminals of the on/o
contact to the input for the on/o
contact of the boiler (TA or LS-LR).
1Connect the module to the heating system

14 15
Heating module Thermostat
Gateway
Electric radiator
Electric radiator
Electric radiator
Electric panel
19.5
19.5
Phase (L)
Neutral (N)
Control wire (P)
30 m
max.
Note: The current circuit of the potential-free contact
must be adjusted to the capacity of the radiators being
controlled. The required current for the control circuit
must be less than 3A.
Attach the heating module holder
2
INSTALLATION OF THE CONTROL WIRE
Installation on electric heating with centralised control wires
- Single zone -
ELECTRIC VERSION

16 17
Gateway
Heating module
Heating module
Heating module
Thermostat
Electric radiator
Electric radiator
Electric radiator
Electric panel
*Protection depending on your installation
19.5
19.5
19.5
19.5
Phase (L)
Neutral (N)
Control wire (P)
30 m
max.
Installation on electric heating with multiple control
wires - Single zone or multi-zone -
Note for multi-zones: You can create up to 10 zones, with one or more radiators in each zone.
To configure your zones, go to "My Account" > "Configure Multi-Zones" once the installation is complete.
1 2
Open the module by
unclipping the back.
Open the heating module.
Then thread the wires through the hole in the
holder. Check the stripping distances of the cables
and wires.
Open the protective cover.

18 19
B. Place the heating module(s) on their
holder.
The on/o light of the heating module(s) must
be on and the communication symbol must be
flashing, indicating that a request for connection
to the thermostat is ongoing.
FP
19.5
3 4
Attach the heating module
holder
Connect the wires
Attach with the dowels and screws.
Connect the three wires as shown. In
general, the phase wire (L) is brown, the
neutral wire (N) is blue and the control
wire (FP) is black.
The cross-sectional area of the cables
used for the power supply (L, N) and
the control wire must be adapted to
the protection installed upstream.
Next steps p. 23
Repeat the installation of
the heating module for each
radiator. Screw the lid back on.
INSTALLATION
A. Switch the power on again
CONTINUATION OF THE STEPS (same for all installations)
Table des matières
Manuels Thermostat populaires d'autres marques

EWELLY
EWELLY EW-181 Manuel utilisateur

Prolon
Prolon T1100 Instructions d'installation

Computherm
Computherm Q20 Manuel utilisateur

Heatmiser
Heatmiser neoStat Manuel utilisateur

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manuel utilisateur

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manuel utilisateur