Coherent Solutions SwitchBlade Manuel utilisateur


Modular Optical Switch |SwitchBlade
i
Copyright © 2017 Coherent Solutions Ltd. All rights reserved. No part of this publication may be reproduced,
stored in a retrieval system or transmitted in any form, be it electronically, mechanically, or by any other
means such as photocopying, recording or otherwise, without the prior written permission of Coherent
Solutions Ltd. (Coherent Solutions).
Information provided by Coherent Solutions is believed to be accurate and reliable.
However, no responsibility is assumed by Coherent Solutions for its use nor for any infringements of patents or
other rights of third parties that may result from its use. No license is granted by implication or otherwise
under any patent rights of Coherent Solutions.
The information contained in this publication is subject to change without notice.
Trademarks
Coherent Solutions’ trademarks have been identified as such. However, the presence or absence of such
identification does not affect the legal status of any trademark.
Units of Measurement
Units of measurement in this publication conform to SI standards and practices.
Version Number: V1.4

Modular Optical Switch |SwitchBlade
ii
Contents
1Conventions ............................................................................................................ 1
2Safety Information................................................................................................... 2
3Introducing the SwitchBlade –Modular Optical Switch ............................................ 3
4SwitchBlade Features .............................................................................................. 5
5MTP1000 Features................................................................................................... 6
6Connecting Optical Output....................................................................................... 7
6.1 Cleaning and Connecting Optical Fibers................................................................................................ 7
7Installing a SwitchBlade Expansion Module.............................................................. 8
8Removing a SwitchBlade Expansion Module .......................................................... 11
9Installing the Software........................................................................................... 14
9.1 Client System Minimum Requirements .............................................................................................. 14
9.2 Test Instrument Manager Software Installation ................................................................................. 14
10 Test Instrument Manager Software........................................................................ 15
10.1 Test Instrument Manager Interface .................................................................................................... 15
10.2 Device Selection .................................................................................................................................. 15
10.3 Main Display........................................................................................................................................ 16
10.4 Switch Selection Control ..................................................................................................................... 17
10.5 Routing Control ................................................................................................................................... 17
10.6 Fiber Type Display ............................................................................................................................... 17
10.7 Other Menu Buttons ........................................................................................................................... 18
11 Programming Guide............................................................................................... 21
11.1 Programming Conventions.................................................................................................................. 21
11.2 Common Command Summary ............................................................................................................ 22
11.3 Common Command Descriptions ....................................................................................................... 22
11.4 Specific Command Summary .............................................................................................................. 23
11.5 Specific Command Descriptions.......................................................................................................... 23
11.5.1 Slot Commands........................................................................................................................... 23
11.5.2 Configuration Commands........................................................................................................... 24
11.6 2x2 SwitchBlade (Crossover) ............................................................................................................... 25
11.7 VISA Programming Example: MATLAB ................................................................................................ 26
11.8 MATLAB Test and Measurement Tool (tmtool)............................................................................... 26
11.9 MATLAB Example Code: Query the MTP1000..................................................................................... 28
12 USB Connection Web Interface .............................................................................. 29
12.1 Network Configuration (Ethernet) ...................................................................................................... 29
12.2 Download Log File ............................................................................................................................... 30
13 Maintenance ......................................................................................................... 31

Modular Optical Switch |SwitchBlade
iii
14 Technical Support .................................................................................................. 33
14.1 Contacting the Technical Support Group ............................................................................................ 33
14.2 Transportation .................................................................................................................................... 33
15 Warranty............................................................................................................... 34
15.1 General Information............................................................................................................................ 34
15.2 Liability ................................................................................................................................................ 34
15.3 Exclusions ............................................................................................................................................ 34
15.4 Certification......................................................................................................................................... 35
15.5 Service and Repairs ............................................................................................................................. 35

Modular Optical Switch |SwitchBlade
Coherent Solutions |SwitchBlade (V1.4) 1
1Conventions
Before using the instrument described in this manual, you should understand the following conventions:
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in
death or serious injury. Do not proceed unless you understand and meet the
required conditions.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in
minor or moderate injury. Do not proceed unless you understand and meet the
required conditions.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in
component damage. Do not proceed unless you understand and meet the required
conditions.
IMPORTANT
Refers to information about this product you should not overlook.

Modular Optical Switch |SwitchBlade
Coherent Solutions |SwitchBlade (V1.4) 2
2Safety Information
WARNING
Do not install or terminate fibers while a light source is active. Care
must be taken to ensure that the instrument has been turned OFF
before inspecting the end face(s) of the instrument, or any optical
patch cords connected to this instrument. Never look directly into a live
fiber and ensure that your eyes are protected at all times.
The use of controls, adjustments and procedures other than those
specified herein may result in exposure to hazardous situations or
impair the protection provided by this unit.
CAUTION
The SwitchBlade expansion modules are sensitive to electrostatic
discharge (ESD). Please be sure to store the modules that are not
installed in protective electrostatic packaging.
IMPORTANT
For electromagnetic compatibility, this instrument is a Class A product. It is
intended for use in an industrial environment. There may be potential
difficulties in ensuring electromagnetic compatibility in other environments,
due to conducted as well as radiated disturbances.
When you see the following symbol on your unit , make sure that you
refer to the instructions provided in your user documentation. Ensure that you
understand and meet the required conditions before using your product.

Modular Optical Switch |SwitchBlade
Coherent Solutions |SwitchBlade (V1.4) 3
3Introducing the SwitchBlade –Modular Optical Switch
The SwitchBlade –Modular Optical Switch is an efficient solution for test procedure automation designed to
be used in the MTP1000 platform. The MEMS based optical switch ensures repeatable and low-loss switching
to various test set-ups while taking advantage of the MTP1000 mainframe’s flexible connectivity and high
channel density form-factor, SwitchBlade easily becomes an integral part of your test set-up.
The modular chassis design of the MTP1000, with nine (9) expansion slots, can hold up to thirty-six (36) optical
switches providing great flexibility to manage the number of switches to meet changing laboratory demands.
Figure 2 - Coherent Solutions MTP1000 Modular Platform with different Blades
Figure 1 - Coherent Solutions SwitchBlade - Modular Optical Switch

Modular Optical Switch |SwitchBlade
Coherent Solutions |SwitchBlade (V1.4) 4
All MTP1000 mainframes connected to the
network can be managed remotely from a
single client using the simple and intuitive
‘Test Instrument Manager’software
interface.
Alternatively, VISA programming
environments such as MATLAB can also be
implemented to integrate with existing test
software or data collection procedures.
Figure 3 - Test Instrument Manager Software

Modular Optical Switch |SwitchBlade
Coherent Solutions |SwitchBlade (V1.4) 5
4SwitchBlade Features
1. Optical Switch Ports*
2. Release latch
*Note: Optical Switch Ports are specific to each model of SwitchBlade. The example shown is a 1x4
model SwitchBlade.

Modular Optical Switch |SwitchBlade
Coherent Solutions |SwitchBlade (V1.4) 6
5MTP1000 Features
MTP1000 Front Panel
3. Power On/Off
4. USB 2.0 Connection
5. Ethernet Connection
6. Laser Interlock (Output Enable/Disable)
7. Blade Expansion Slots (9 Bays)
MTP1000 Back Panel
8. Thermal Regulation Fans (6)
9. Mains Power Isolation Switch
10. AC Power 100-240V, 50-60Hz
Table des matières
Autres manuels Coherent Solutions Changer